LOCATION
Inselecting thelocation,theaestheticandfunc-
tionaluseoftheapplianceareprimaryconcerns.
However, vent system routing to the outside
atmosphere and access to the fuel supply are
alsoimportant.Considerationshouldbegivento
traffic ways, furniture, draperies, etc., due to
high surface temperatures (
see Figure 2
). The
locationshouldalsobefreeofelectrical,plumb-
ing or other heating/air conditioning ducting.
Thesedirectventappliancesareuniquelysuited
for installations requiring a utility shelf posi-
tioneddirectlyabovethefireplace.Utilityshelves
likethese arecommonlyusedforlocatingtele-
vision sets and decorative plants.
Toachievethe lowestpossibleshelf height, use
the alternative rear vent outlet. Do not insulate
the space between the appliance and the area
aboveit.See
Figure 3onpage4
.Theminimum
height from the base of the appliance to the
undersideofcombustiblematerialsusedtocon-
structautilityshelfinthisfashionisshowninthe
table in
Figure 3 on page 4
.
Table 1
Test gage connections are provided on the
front of the millivolt gas control valve (iden-
tified IN for the inlet and OUT for the mani-
fold side). A 1/8" NPT test gage connection
is provided at the inlet and outlet side of
the electronic gas control valve.
Minimum inlet gas pressure to these appli-
ances is 5.0 inches water column (1.24 kPa)
for natural gas and 11.0 inches water column
(2.74kPa)forpropaneforthepurposeofinput
adjustment.
Maximum inlet gas supply pressure to these
appliances is 10.5 inches water column (2.61
kPa) for natural gas and 13.0 inches water col-
umn (3.23 kPa) for propane.
Do not use these appliances if any part has
been under water. Immediately call a quali-
fied, professional service technician to in-
spect the appliance and to replace any parts
of the control system and any gas control
which have been under water.
Themillivoltappliancesaremanuallycontrolled
and feature a spark ignitor (piezo) that allows
theappliance'spilotgastobelitwithouttheuse
of matches or batteries. This system will still
function in the event of a power outage.
Installations at Altitudes of 0 to 4500 ft.-
Unitsaretested andapproved forelevations
of 0 to 4500 feet (0 to 1372 meters).
Installations at Altitudes above 4500 ft.-
For elevations above 4500 feet (1372
meters), install the unit according to the
regulations of the local authorities having
jurisdictionand,intheUSA,thelatestedition
ofthe NationalFuelGas Code(ANSI Z223.1)
or, in Canada, the latest edition of the
CAN1-B149.1 and .2 codes.
This appliance may be installed in an af-
termarket permanently located, manufac-
tured home (USA only) or mobile home,
where not prohibited by local codes. This
appliance is only for use with the type of
gas indicated on the rating plate. This ap-
pliance is not convertible for use with other
gases, unless a certified kit is used.
Cetappareilpeutêtreinstallédansunmaison
préfabriquée (É.-U. seulement) ou mobile
déjàinstallée àdemeure si les réglements
locaux le permettent. Cet appareil doit être
utiliséuniquementaveclestypesdegazindiqués
sur la plaque signalétique. Ne pas l'utiliser
avec d'autres gaz sauf si un kit de conversion
certifiéest installé.
Theseappliances mustbe isolatedfrom thegas
supplypipingsystem(byclosingtheirindividual
manualshut-offvalve)duringanypressuretest-
ing of the gas supply piping system at test
pressuresequaltoorlessthan¹⁄₂ psig(3.5kPa).
Theseappliances andtheir individualshut-off
valves must be disconnected from the gas
supply piping system during any pressure
testingofthatsystematpressuresinexcessof
1/2 psig (3.5 kPa).
Theseappliances must not be connectedto a
chimney or flue serving a separate solid fuel
burning appliance.
These heater rated appliances are intended
for use as supplemental heaters only.
Carbon Monoxide Poisoning: Early signs of
carbon monoxide poisoning are similar to the
fluwith headaches,dizziness and/or nausea.If
you have these signs, obtain fresh air immedi-
ately. Turn off the gas supply to the appliance
and have it serviced by a qualified profes-
sional, as it may not be operating correctly.
Electronic Models -
Electronic models have a fixed rate gas valve.
Input of electronic models is shown in the
following table:
All Models -
Maximum manifold pressure is 3.5 in. w.c.
(0.87 kPa) for natural gas and 10 in. w.c.
(2.49 kPa) for LP/Propane gas.
sledoMtlovilliM
enaporPdnalarutaN sledoMsaG )H/UTB(etartupnI detaludom-yllaunaM
,MNFPVDE,MNTSVDE ,MNRCVDE,MNLCVDE ,MPFPVDE,MPTSVDE MPRCVDE,MPLCVDE
000,93OT000,13
ledoM .oN
ezisecifirO noitavelE teeF )sretem(
.taN.porP
TSVDE FPVDE RCVDE LCVDE
"521.094# 0054-0 )2731-0(
Ne pas se servir de cet appareil s'il a été
plongédans l'eau, complètement ou en
partie. Appelerun technicien qualifiépour
inspecter l'appareil et remplacer toute
partie du système de contrôle et toute
commande qui ont étéplongés dans l'eau.
Input of millivolt models is shown in the fol-
lowing table: WARNING: FAILURE TO COMPLY WITH
THEINSTALLATIONANDOPERATINGIN-
STRUCTIONSPROVIDED INTHISDOCU-
MENT WILL RESULT IN AN IMPROP-
ERLY INSTALLED AND OPERATING AP-
PLIANCE, VOIDING ITS WARRANTY.
ANY CHANGE TO THIS APPLIANCE AND/
OR ITS OPERATING CONTROLS IS DAN-
GEROUS. IMPROPER INSTALLATION
ORUSEOFTHISAPPLIANCECANCAUSE
SERIOUSINJURYORDEATHFROMFIRE,
BURNS, EXPLOSION OR CARBON MON-
OXIDE POISONING.
WARNING: CHILDREN AND ADULTS
SHOULD BE ALERTED TO THE HAZARDS
OFHIGHSURFACETEMPERATURES.USE
CAUTION AROUND THE APPLIANCE TO
AVOID BURNS OR CLOTHING IGNITION.
YOUNG CHILDREN SHOULD BE CARE-
FULLY SUPERVISED WHEN THEY ARE IN
THE SAME ROOM AS THE APPLIANCE.
WARNING: DO NOT PLACE CLOTHING
OR OTHER FLAMMABLE MATERIALS
ON OR NEAR THIS APPLIANCE.
AVERTISSEMENT: SURVEILLER LES
ENFANTS. GARDER LES VÊTEMENTS,
LESMEUBLES, L'ESSENCEOUAUTRES
LIQUIDES ÀVAPEUR INFLAMMABLES
ÀCOTE DE L'APPAREIL.
Table 1
shows the units' gas orifice size for
theelevationsindicated.