Fill the hopper with pellets
Make sure the hopper lid is completely closed
Turn the “IGNITION / HEAT CONTROL” dial clock-
wise to begin the ignition cycle
1.
2.
3.
Open hopper lid and fill hopper with pellets
Make sure the hopper lid is completely closed when
finished re-fueling
If hopper lid is open for more than 45 seconds,
shutdown mode will start automatically. After re-fuel-
ing, ensure Controller reads “HEATING”, if it doesn’t,
reset by turning “IGNITION/HEAT CONTROL” dial
to off, then back to the desired heating level.
1.
2.
3.
Turn the “IGNITION / HEAT CONTROL” dial to
the “OFF” position (The blowers will automatically turn
off once the stove has cooled down)
1.
FLAME APPEARANCE
PROPERLY ADJUSTED FLAME IMPROPERLY ADJUSTED FLAME
OFF
MIN MAX
LOW
HIGH
FAN HEAT
FAN SPEED
IGNITION / HEAT CONTROL
MF 253 347 3252
OFF START
3
The appearance of the flame can be a good indicator of the overall performance of the stove. A bright clean flame indicates
there is a proper balance of fuel and combustion air which results in efficient burning. A dark slow-moving flame indicates
incomplete combustion and a stove that may be in need of service and/or adjustment (see Damper Adjustment, next page).
MANUAL OPERATION*
2
OFF
MIN MAX
LOW
HIGH
FAN HEAT
FAN SPEED
IGNITION / HEAT CONTROL
WARNING
DO NOT REMOVE COVER
HIGH VOLTAGE INSIDE
NO USER SERVICEABLE COMPONENTS
FOR SERVICE, CONTACT YOUR DEALER
SENSORS
J3
DC AUGER
J2
AC POWER
J1
MAIN FUSE - 3 AMP 250V
F1
IGNITOR FUSE - 6 AMP 250V
F2
DIAGNOSTIC
J6 THERMOSTAT
J5
!
FRONT
BELLA CONTROL BOARD
BACK
Fan Speed
The fan speed dial is used to vary the output
of the room fan. Note: The room fan will turn
on automatically when the stove has reached
sufficient operating temperature and will turn
off when the stove cools down.
The LCD Screen displays information
on the stove’s current mode of opera-
tion. See Installation and Operation
Manual for detailed explanation of
messages.
Ignition / Heat Control
The ignition / heat control dial
is used to initiate startup and
shutdown, as well as to control
the heat output of the stove over
five levels, from low to high.
Hopper lid must
be closed during
operation.
The control board is located on the right
side of the stove.
* Refer to the Installation and Operation Manual if you are connecting your stove to a thermostat. Ignition and
control board functions for automatic (thermostat) operation may be different from the explanations given above.
SHARP, ACTIVE
FLAME
BRIGHT YELLOW HUE
PELLET EMBERS
ACTIVELY MOVE IN
THE BURN POT
•
•
•
SLOW LAZY FLAME
DARK ORANGE HUE
LARGE FLAME WITH
BLACK SOOTY TIPS
PELLETS BUILD UP IN
THE BURN POT
WINDOW BECOMES
DIRTY MORE QUICKLY
•
•
•
•
•
STARTING THE BELLA™ PELLET STOVE
RE-FUELING WHILE IN OPERATION
STOPPING THE BELLA PELLET STOVE
The stove burns cleanly and heats efficiently. Requires more frequent maintenance and can be unsafe
to operate.
OFF
MIN MAX
LOW
HIGH
FAN HEAT
FAN SPEED
IGNITION / HEAT CONTROL
IGNITING
OFF START
Digital Display
OFF
MIN MAX
LOW
HIGH
FAN HEAT
FAN SPEED
IGNITION / HEAT CONTROL
WARNING
DO NOT REMOVE COVER
HIGH VOLTAGE INSIDE
NO USER SERVICEABLE COMPONENTS
FOR SERVICE, CONTACT YOUR DEALER
SENSORS
J3
DC AUGER
J2
AC POWER
J1
MAIN FUSE - 3 AMP 250V
F1
IGNITOR FUSE - 6 AMP 250V
F2
DIAGNOSTIC
J6 THERMOSTAT
J5
!
FRONT
BELLA CONTROL BOARD
BACK
OFF
MIN MAX
LOW
HIGH
FAN HEAT
FAN SPEED
IGNITION / HEAT CONTROL
WARNING
DO NOT REMOVE COVER
HIGH VOLTAGE INSIDE
NO USER SERVICEABLE COMPONENTS
FOR SERVICE, CONTACT YOUR DEALER
SENSORS
J3
DC AUGER
J2
AC POWER
J1
MAIN FUSE - 3 AMP 250V
F1
IGNITOR FUSE - 6 AMP 250V
F2
DIAGNOSTIC
J6 THERMOSTAT
J5
!
FRONT
BELLA CONTROL BOARD
BACK
OFF
MIN MAX
LOW
HIGH
FAN HEAT
FAN SPEED
IGNITION / HEAT CONTROL
WARNING
DO NOT REMOVE COVER
HIGH VOLTAGE INSIDE
NO USER SERVICEABLE COMPONENTS
FOR SERVICE, CONTACT YOUR DEALER
SENSORS
J3
DC AUGER
J2
AC POWER
J1
MAIN FUSE - 3 AMP 250V
F1
IGNITOR FUSE - 6 AMP 250V
F2
DIAGNOSTIC
J6 THERMOSTAT
J5
!
FRONT
BELLA CONTROL BOARD
BACK
OFF
MIN MAX
LOW
HIGH
FAN HEAT
FAN SPEED
IGNITION / HEAT CONTROL
WARNING
DO NOT REMOVE COVER
HIGH VOLTAGE INSIDE
NO USER SERVICEABLE COMPONENTS
FOR SERVICE, CONTACT YOUR DEALER
SENSORS
J3
DC AUGER
J2
AC POWER
J1
MAIN FUSE - 3 AMP 250V
F1
IGNITOR FUSE - 6 AMP 250V
F2
DIAGNOSTIC
J6 THERMOSTAT
J5
!
FRONT
BELLA CONTROL BOARD
BACK