MSX-3420 EasyFill
™
X Autofill
System
User Manual
Thank you for purchasing the Level Waters ™ MSX-3420
EasyFill X
TM
Electronic autofill system. It is the smallest
automatic, completely electronic water level sensing unit on
the market.
The MCX-11 control sensing unit incorporates a dependable
patent pending sensing process and includes features found
only on large professional systems, like the wave
compensation delay and third failsafe probe. It may be used
in many applications including ponds, water gardens,
fountains and other water features. It is also suited for large
industrial applications like cooling towers water make up.
The Unit uses no external moving parts and will not clog like
standard float valves can. It is hand assembled from PVC
material instead of molded ABS plastic. PVC provides for
better endurance in sunlight and heat and will extend the life
of the components over time than using other plastics would.
The MCX-11 control sensor provides dependable filling in a
simple design to achieve an optimum water level. Installation
is a snap with simple plumbing and wiring.
For more information on our full line of professional leveling
systems, visit us on the web at www.aquilitysystems.com.
Safety Overview
The EasyFill X
TM
Pond Water Level Sensing Unit is designed
to provide the user a safe product that is easy to install and
use. When installed as described in this manual, the system
presents no unsafe shock hazards. However, altering any of
the components may present an unsafe circumstance.
Some other considerations to keep in mind during
installation and operations are as follows:
Always use a Class 2 power limiting supply.
Never mount a power supply made for indoor use in an
outdoors environment where it will get wet. Follow all
manufacturer instructions when installing a power
supply.
Do not insert metal objects into sensor probes while unit is
turned on.
Do not break seals on unit. Doing so may expose the user
to potentially dangerous voltages when unit is turned on and
will void the warranty.
Do not plug the power supply in until all wiring is complete
and leads are not exposed!
Always use safety equipment, such as eye protection, and
dust mask when cutting PVC piping along with other normal
safety precautions.
Always carefully follow all installation instructions.
Installation
The MSX-3420 Automatic Water Leveling System is simple
to install. A waterproof outlet cover will need to be installed
on the power receptacle to protect the power transformer.
These may be purchased from many local hardware stores.
Installation will also require simple PVC pipe installation and
screw mounting the snap-in mount or the sensing unit along
with simple wiring. The limited plumbing that is necessary to
provide the system with filling water requires only a hacksaw
(or other appropriate saw), PVC cement and sufficient PVC
and adapters.
Preparing for Installation
Open the package and ensure that all of the components are
present and have not been damaged in shipping. Items
included in the system are:
• MCX-11 EasyFill X
TM
Control/Sensing Unit
• PS-24A 450ma power supply
• ¾" 24VAC Fill Valve
• MNT-EZX Snap-In Mount
• Mounting Accessory Kit
• Probe cleaning wire brush
Remove the control sensor from the MNT-EZX by carefully
pushing the capture post over the edge of the sensor and
angling the sensor out.
Identify where the EasyFill X
TM
will be mounted. The fill valve
should be mounted within 50 feet of the control wires on the
EasyFill X
TM
and connected using irrigation zone wire. An
outside water feed, such as a spigot will need to be run to
the valve and then to the water feature that will be filled.
A weather-protected receptacle for power will need to be
located within a maximum of six feet of the EasyFill X
TM
Sensing Unit to install the power module. Do not extend the
power wires or the unit may not sense properly and doing so
will void the warranty.
Warning! Always consult with an electrician when installing
electrical wiring! Not doing so could result in a dangerous
condition and/or noncompliance with electrical codes.
Installing the Sensing Unit
Determine a location where the EasyFill X
TM
sensing unit will
be mounted (try to find an inconspicuous place.). If the unit is
to be mounted in a skimmer, locate the surface it will mount
on and verify that the sensor window will maintain the level
at the optimum height for the
skimmer.
Position the MNT-EZX Snap
Mount so the bottom edge of the
mount is at the lowest desired
water level. To avoid overflows,
the middle short probe should be
below the pond edge. If the sensor
height will need to be adjusted, MNT-EZ/SL adjustable
mount (sold separately) will need to be installed. This will not
be needed for most installations.
Mark the mounting surface to match the two mounting holes
in the MNT-EZX Snap Mount. (If no holes are desired, the
unit may be affixed using silicone sealant) Drill a small #4
pilot hole at the marks and screw the snap mount snuggly to
the mounting surface with the #6 flathead stainless screws
provided. DO NOT over-tighten the screws!
Install the MCX-11 sensor control by angling it so that one of
the mounting holes is above the corresponding stand-off
posts and firmly but gently push the sensor housing into the
clamp so that both latches catch the top edge of the sensor
control.
Installing the Fill Valve
Plumb the input and output of the fill valve (follow
manufacturer’s instructions for valve) to an always-on water
source using PVC pipe or garden hose (see ‘Plumbing the
Unit’ for PVC installation tips). We recommend installing a
ball valve on the output of the fill valve to control flow volume
to the water feature.
Warning! The fill valve must be installed in an upright
position with the wires extending upwards from the unit
to function correctly.
Wiring the System
Wiring the EasyFill X
TM
control sensing unit to the power
supply and fill valve requires that each connection be sealed
from water using the supplied self-adhering tape and
electrical sealant.
Warning! Do not plug the power supply in until all wiring
is complete and leads are not exposed!
Remove precut insulation from sensor wire ends. Connect
valve wires as shown in Diagram 2 using wire nuts provided.
Bend wire nut connection flat to length of wire and wrap with
self-adhering tape making sure to create a proper watertight
seal. Plug the power supply connector into the black sensor
power connector and seal with self-adhering tape. Apply a
liquid electrical sealant (available at most hardware stores)
to each connection. We recommend that the unit be tested
before weatherproofing the connectors.
Note: It does not matter which red wire from the valve are
used when wiring.
Connection Power Lead Sensor Lead Valve Lead
1 1 Black 1 Black ---
2 --- 1st Red 1st Red
3 --- 2nd Red 2nd Red
Plumbing the Unit
Using ¾” PVC pipe (available at most hardware stores) run
water supply from the fill valve outlet to the pond routing it
the way desired.
Parts needed:
• Hacksaw (or other suitable fine-toothed saw)
• PVC glue
• Required lengths of 3/4” PVC
• Required angle adapters.
Cut and fit all PVC pipe from the fill valve to the water
feature without gluing to make sure that the pipes are where
the user desires them.
Clean and glue all parts with general PVC cement to form a
watertight seal. Allow joints to dry for 24 hours before
connecting water to the system.
Plug the power supply into the weather-protected receptacle.
The unit is ready for operation
Operation
Once the EasyFill X
TM
is connected properly and plugged in it
will fill anytime the water level drops below the sensor
probes after a delay of between 10 - 40 seconds.
Note! If the level of the water at the time of power up is low,
the unit will fill until the water level reaches the probes before
turning off. Maintenance
The EasyFill X
TM
requires very little maintenance. To maintain
optimal performance, periodically clean the sensor probes
with the supplied wire brush, to remove debris and film. No
other maintenance is required.
Troubleshooting
The MSX-3420 EasyFill X
TM
Automatic Pond Leveling
System should maintain the level in your pond for many
worry-free years. However, if you should experience
problems with it, it may be caused by some of these
common issues that can be resolved by the user:
 Pond overflows when filling
 Verify valve is installed upright, flow
direction is correct and manual fill screw
is tight.
 Readjust sensor height to lower water
level.
 Clean the probes thoroughly with the
supplied wire brush.
 Water has become ground potential or
there is a voltage leak. Check pumps
and submerged equipment for shorts.
 Pond will not fill
 Check to make sure power is available
at receptacle.
 Check for debris on sensor probes and
in between them and clean per
instructions.
 Check to ensure connections are not
damaged and are covered with
weatherproof tape or sealant. Allow
connections to dry if necessary and seal
per the instructions.
Warranty
Aquility Systems, Inc warrants this product to the original
purchaser for a period of two years against defects in
material or workmanship when used for normal residential
purposes it is intended for. In order to obtain a replacement
unit or repair the existing unit, you must obtain a RMA
number and return the complete unit, postage prepaid, to the
place of purchase, or to the Aquility Systems facility. (6949
SW 21
st
Lane, Gainesville, FL 32607)
This warranty is intended to cover product defects only.
Aquility Systems, Inc. is not liable for indirect, incidental or
consequential damages in connection with the use of the
Level Waters product covered by this warranty. This
warranty does not cover any cost or expense incurred by the
purchaser in providing substitute equipment or service
during reasonable periods of malfunction or non-use of this
product, while waiting for completion of repairs under this
warranty. Some states do not allow exclusions of incidental
or consequential damages, so the above exclusions may not
apply in all states. This warranty gives you specific legal
rights in your state, which vary from state to state.
If you wish to contact Aquility Systems, Inc., please direct
inquiries to:
Customer Service
Aquility Systems, Inc.
6949 SW 21
st
Ln.
Gainesville, FL 32607or by email at
support@aquilitysystems.com
Copyright 2020 Aquility Systems, Inc. All Rights Reserved.

Popular Security Sensor manuals by other brands

SICK GLS100 quick start

SICK

SICK GLS100 quick start

Cardin Elettronica Mini FTR893 Series manual

Cardin Elettronica

Cardin Elettronica Mini FTR893 Series manual

delight 18695 user manual

delight

delight 18695 user manual

Crow SRDT-15 installation instructions

Crow

Crow SRDT-15 installation instructions

Honeywell FF-SPS4 Series installation manual

Honeywell

Honeywell FF-SPS4 Series installation manual

Qazqa Rana WL PIR LUX LED Solar instruction manual

Qazqa

Qazqa Rana WL PIR LUX LED Solar instruction manual

Elkron IR15P manual

Elkron

Elkron IR15P manual

ERMENRICH Ping ES20 user manual

ERMENRICH

ERMENRICH Ping ES20 user manual

UMAX Technologies U-Smart Door Sensor user manual

UMAX Technologies

UMAX Technologies U-Smart Door Sensor user manual

Technoalarm UTS 4.3 PROX manual

Technoalarm

Technoalarm UTS 4.3 PROX manual

Gewiss Chorus GW 10 786 Technical manual

Gewiss

Gewiss Chorus GW 10 786 Technical manual

ELCART TMR TL-500 instruction manual

ELCART

ELCART TMR TL-500 instruction manual

Signtex Lighting RPROAC Series Installation instructions & user manual

Signtex Lighting

Signtex Lighting RPROAC Series Installation instructions & user manual

AccuLine 40-6700 instruction manual

AccuLine

AccuLine 40-6700 instruction manual

AKO AKO-52062 installation guide

AKO

AKO AKO-52062 installation guide

GEZE GC 333 C quick start guide

GEZE

GEZE GC 333 C quick start guide

urmet domus 1033 Installation and instruction manual

urmet domus

urmet domus 1033 Installation and instruction manual

Intermatic IOS-CMP-DT-LV Installation and configuration instructions

Intermatic

Intermatic IOS-CMP-DT-LV Installation and configuration instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.