IES-2880 User Manual Page 2
Preface
This manual describes how to install and use the Industry Managed Ethernet Switch.This
switch introduced here is designed to deliver full scalability with SNMP/RMON web-based
management functions by providing:
To get the most out of this manual, you should have an understanding of Ethernet
networking concepts.
In this manual, you will find:
Features on the Industry Managed Ethernet Switch
Illustrative LEDfunctions
Installation instructions
Management Configuration

Specifications
IES-2880 User Manual Page 3
Table of Contents
PREFACE....................................................................................................................................................... 2
QUICK START GUIDE ..................................................................................................................................... 5
FUNCTIONAL DESCRIPTION ....................................................................................................................................... 5
PHYSICAL DESCRIPTION ............................................................................................................................................ 6
CONSOLE CONFIGURATION ....................................................................................................................................... 7
WEB CONFIGURATION ............................................................................................................................................. 9
PRODUCT OVERVIEW ................................................................................................................................. 10
INDUSTRY MANAGED ETHERNET SWITCH................................................................................................................... 10
PACKAGE CONTENTS.............................................................................................................................................. 10
PRODUCT HIGHLIGHTS ........................................................................................................................................... 11
FRONT PANEL DISPLAY ........................................................................................................................................... 13
PHYSICAL PORTS ................................................................................................................................................... 14
SWITCH MANAGEMENT ......................................................................................................................................... 15
INSTALLATION ............................................................................................................................................ 16
SELECTING A SITE FOR THE SWITCH........................................................................................................................... 16
CONNECTING TO POWER ........................................................................................................................................ 16
CONNECTING TO YOUR NETWORK ............................................................................................................................ 18
SWITCH MANAGEMENT ............................................................................................................................. 19
MANAGEMENT ACCESS OVERVIEW........................................................................................................................... 19
ADMINISTRATION CONSOLE (CLI) ............................................................................................................................ 20
WEB MANAGEMENT ............................................................................................................................................. 21
SNMP-BASED NETWORK MANAGEMENT ................................................................................................................. 21
PROTOCOLS ......................................................................................................................................................... 21
MANAGEMENT ARCHITECTURE ................................................................................................................................ 22
SNMP & RMON MANAGEMENT ................................................................................................................. 23
OVERVIEW........................................................................................................................................................... 23
SNMP AGENT AND MIB-2 (RFC 1213) .................................................................................................................. 23
RMON MIB (RFC 2819) &BRIDGE MIB (RFC 1493).............................................................................................. 24
WEB-BASED BROWSER MANAGEMENT ...................................................................................................... 26
LOGGING ON TO THE SWITCH................................................................................................................................... 26
UNDERSTANDING THE BROWSER INTERFACE ............................................................................................................... 27
SYSTEM............................................................................................................................................................... 29
PORT.................................................................................................................................................................. 37
SWITCHING.......................................................................................................................................................... 42
TRUNKING ........................................................................................................................................................... 46
STP/RING ......................................................................................................................................................... 47
VLAN ................................................................................................................................................................ 56
QOS................................................................................................................................................................... 61
SNMP ............................................................................................................................................................... 64
802.1X.............................................................................................................................................................. 68
OTHER PROTOCOLS ............................................................................................................................................... 71
COMMAND LINE CONSOLE MANAGEMENT ................................................................................................ 75
ADMINISTRATION CONSOLE .................................................................................................................................... 75
SYSTEM............................................................................................................................................................... 88
PORT.................................................................................................................................................................. 95
IES-2880 User Manual Page 4
SWITCHING........................................................................................................................................................ 100
TRUNKING ......................................................................................................................................................... 105
STP /RING ....................................................................................................................................................... 106
VLAN .............................................................................................................................................................. 119
QOS................................................................................................................................................................. 125
SNMP ............................................................................................................................................................. 128
802.1X............................................................................................................................................................ 137
OTHER PROTOCOLS ............................................................................................................................................. 142
SPECIFICATIONS ........................................................................................................................................153
APPENDIX A ..............................................................................................................................................154
APPENDIX B ..............................................................................................................................................155
IES-2880 User Manual Page 5
Quick Start Guide
This quick start guide describes how to install and use the Industry Managed Ethernet
Switch.This is the switch of choice for harsh environments constrained by space.
Functional Description
Meets NEMATS1/TS2 Environmental requirements such as temperature, shock, and
vibration for traffic control equipment.
Meets EN61000-6-2 & EN61000-6-4 EMC Generic Standard Immunity for industrial
environment.
RS-232 console,Telnet, SNMP v1 & v2c & v3, RMON,Web Browser, andTFTP
management.
Supports Command LineInterface in RS-232 console.
Supports 8192 MAC addresses. Provides 3M bits memory buffer.
Supports IEEE802.3/802.3u/802.3ab/802.3z/802.3x. Auto-negotiation:
1000Mbps-full-duplex; 10/100Mbps-full/half-duplex; Auto MDI/MDIX.
100Base-FX: Multi mode SC or ST type, Single mode SC or ST type; 100Base-BX:WDM
Single mode SC type.
1000Base-SX/LX: Multi mode SC type, Single mode SC type; 1000Base-BX:WDM Single
mode SC type.
SFP socket forGigabit fiber optic expansion.
Store-and-forward mechanism.
Full wire-speed forwarding rate.
AC inlet power socket: 100~240VAC, 50~60Hz internal universal PSU.
Terminal Block powerinput: +48VDC, -48VDC, 88~370VDC, or 90~264VAC.
Supports redundant powersupplies for flexible application.
24 FE + 4 GE Combo SFP Managed Switch -40 to 75CIndustry metal case.
Supports Rack Mounting installation.
IES-2880 User Manual Page 6
Physical Description
The Port Status LEDs and Power Inputs
LED
State
Indication
Power
Steady
Power on
Off
Power off
10/100Base-TX, 100Base-FX/BX
Link/ACT
Steady
A valid networkconnection
established
Flashing
Transmitting or receiving data
ACT stands for ACTIVITY
10/100/1000Base-TX, SFP, 1000Base-SX/LX/BX
Link/ACT
Steady
A valid networkconnection
established
Flashing
Transmitting or receiving data
ACT stands for ACTIVITY
SFP
SFP
Steady
A valid SFP connection
established
Off
Without SFP
IES-2880 User Manual Page 7
Terminal Block Power Input
+48VDC
-48VDC
88-370VDC
90-264VAC
0
-48
0
N
+
+48
0
88-370
L
Earth Ground
Protect Ground
<Note> Dielectric withstand (Hipot) test for DC power input, must remove metal chip between Earth
Ground and Protect Ground of the terminal block power input to avoid damage to the Switch.
Console Configuration
Connect to the switch console:
Connect the DB9 straight cable to the RS-232 serial port of the device and the RS-232
serial port of the terminal or computer running the terminal emulation application.
Direct access to the administration console is achieved by directly connecting a
terminal or a PC equipped with a terminal-emulation program (such as HyperTerminal)
to the switch console port.
Configuration settings of the terminal-emulation program:
Baud rate: 115,200bps
Data bits: 8
Parity: none
Stop bit: 1
Flow control: none

Logon to Exec Mode (View Mode):
ll show on the screen.
Logon to Privileged Exec Mode (Enable Mode):
screen.
IES-2880 User Manual Page 8
Logon to Configure Mode (ConfigureTerminal Mode):
will show on the screen.
Set new IP address and subnet mask for Switch:
-
on the screen.
-et new IP address (192.168.1.10) and new IP
subnet mask (255.255.255.0) forSwitch.
IES-2880 User Manual Page 9
Web Configuration
Login theswitch:
Specify the default IP address (192.168.1.10) of the switch in the web browser. A login
window will be shown as below:
Enter the factory default login ID: root.
Enter the factory default password (no password).
IES-2880 User Manual Page 10
Product Overview
Industry Managed Ethernet Switch
Front View
Package Contents
When you unpack the product package, you shall find the items listed below. Please
inspect the contents,and report any apparent damage or missing items immediately to
your authorized reseller.
IES-2880
Quick Installation Guide
CD UserManual
RS-232 cable
Rackmount brackets with screws

Other LevelOne Switch manuals

LevelOne FGP-1072 User manual

LevelOne

LevelOne FGP-1072 User manual

LevelOne GSW-0800TXM User manual

LevelOne

LevelOne GSW-0800TXM User manual

LevelOne FGP-1031 User manual

LevelOne

LevelOne FGP-1031 User manual

LevelOne GEL-5271 User manual

LevelOne

LevelOne GEL-5271 User manual

LevelOne ViewCon KVM-0850 User manual

LevelOne

LevelOne ViewCon KVM-0850 User manual

LevelOne FEP-0311 User manual

LevelOne

LevelOne FEP-0311 User manual

LevelOne FEP-0631 User manual

LevelOne

LevelOne FEP-0631 User manual

LevelOne Infinity IES-1085 User manual

LevelOne

LevelOne Infinity IES-1085 User manual

LevelOne IES-0853 User manual

LevelOne

LevelOne IES-0853 User manual

LevelOne KVM-0306 User manual

LevelOne

LevelOne KVM-0306 User manual

LevelOne KVM-0221 User manual

LevelOne

LevelOne KVM-0221 User manual

LevelOne SoHoCon FSW1602TX User manual

LevelOne

LevelOne SoHoCon FSW1602TX User manual

LevelOne GEU-0522 User manual

LevelOne

LevelOne GEU-0522 User manual

LevelOne GEP-1022 User manual

LevelOne

LevelOne GEP-1022 User manual

LevelOne FEU-0812 User manual

LevelOne

LevelOne FEU-0812 User manual

LevelOne OfficeCon GSW-2440 User manual

LevelOne

LevelOne OfficeCon GSW-2440 User manual

LevelOne Infinity IES-0510 User manual

LevelOne

LevelOne Infinity IES-0510 User manual

LevelOne IES-0842 User manual

LevelOne

LevelOne IES-0842 User manual

LevelOne GEP-2450 User manual

LevelOne

LevelOne GEP-2450 User manual

LevelOne GEU-0521 User manual

LevelOne

LevelOne GEU-0521 User manual

LevelOne GSW-4876 User manual

LevelOne

LevelOne GSW-4876 User manual

LevelOne 59910203 User manual

LevelOne

LevelOne 59910203 User manual

LevelOne IES-0840 User manual

LevelOne

LevelOne IES-0840 User manual

LevelOne ProCon GSW-1290 User manual

LevelOne

LevelOne ProCon GSW-1290 User manual

Popular Switch manuals by other brands

Alewings ESC micro MGN Usage manual

Alewings

Alewings ESC micro MGN Usage manual

Digitus DS-14210 user manual

Digitus

Digitus DS-14210 user manual

Brocade Communications Systems ServerIron ADX 12.4.00 Manual guide

Brocade Communications Systems

Brocade Communications Systems ServerIron ADX 12.4.00 Manual guide

H3C S9500 Series installation manual

H3C

H3C S9500 Series installation manual

Emerson Rosemount 2410 Manual supplement

Emerson

Emerson Rosemount 2410 Manual supplement

TP-Link JetStream T1500G-10MPS How to Upgrade

TP-Link

TP-Link JetStream T1500G-10MPS How to Upgrade

ATEN CL5716I user manual

ATEN

ATEN CL5716I user manual

Amulet Hotkey K4u manual

Amulet Hotkey

Amulet Hotkey K4u manual

ZyXEL Communications ES-2024 Series user manual

ZyXEL Communications

ZyXEL Communications ES-2024 Series user manual

Network Technologies PRIMUX-16X64 Installation and operation manual

Network Technologies

Network Technologies PRIMUX-16X64 Installation and operation manual

Dell PowerConnect 2216 Technical Specifications Update

Dell

Dell PowerConnect 2216 Technical Specifications Update

Idem KLTM-RFID operating instructions

Idem

Idem KLTM-RFID operating instructions

Moxa Technologies ETHERDEVICE EDS-305 Hardware installation guide

Moxa Technologies

Moxa Technologies ETHERDEVICE EDS-305 Hardware installation guide

HBC H3C S5130-E Series manual

HBC

HBC H3C S5130-E Series manual

WIKA TS-972 operating instructions

WIKA

WIKA TS-972 operating instructions

ANTAIRA LMX-2602G-SFP Series Hardware manual

ANTAIRA

ANTAIRA LMX-2602G-SFP Series Hardware manual

AC Ryan VEOLO2 user manual

AC Ryan

AC Ryan VEOLO2 user manual

Lindy 39123 Short user manual

Lindy

Lindy 39123 Short user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.