ACN-2Z USER MANUAL
ACN-2Z
(pulse alarm system)
TEC NICAL SPECIFICATIONS:
1. Number of monitored sections of the district heating pipeline..........................................................................2
2. Maximum length of monitored sections of the district heating pipeline.................................................2000 m
3. Minimum polyurethane insulation resistance..................................preset: 100 Ω–550 Ω at 50-Ω increments*)
4. Polyurethane insulation resistance measuring accuracy.............................................................................±10%
5. Signal description:
Polyurethane insulation resistance between the copper LEDs, green
wire and the carrier pipe exceeds 550 Ω.....description: “STAN DOBRY” (GOOD CONDITION)
The alarm system is in good condition...............................................................................................
Polyurethane insulation resistance between the copper LEDs, red
wire and the carrier pipe does not exceed 550 Ω.......................................................continuously lit
The alarm system is in good condition......................................description: “PRZECIEK” (LEAK)
Direct contact of the copper wire with the carrier pipe LEDs, red
Measured resistance is lower than 50 Ω. blinking
description: “PRZECIEK” (LEAK)
There is an electrical break in the alarm system of the LEDs, red
monitored district heating pipeline. continuously lit
description: “PRZERWA” (BREAK)
6. Description of the “ALARM” output used to control an external alarm device:
Contacts are open in case of the “AWARIA” (FAULT) status or power outage.
Acceptable contact voltage:
– AC..........................................................................................................................................120 V
– DC............................................................................................................................................24 V
Connection power.........................................................................................24 W (DC); 60 VA (AC)
Maximum continuous load current....................................................................1 A (DC); 0.5 A (AC)
7. Method of communication with data ac uisition systems:
Status of relay contacts (NC; NO; COM)......................................................................ALARM port
8. Current draw...........................................................................................................................................0.75 VA
9. Power supply...................................................................................................................................230 V 50 Hz
10.Operating temperature range.............................................................................................................5 to +50°C
11.Relative humidity................................................................................................................................up to 80%
12. Housing protection rating...........................................................................................................................IP54
13. Appliance class................................................................................................................................................B
14. Dimensions.....................................................................................................................................180x160x60
15. Instrument weight.....................................................................................................................................850 g
*) Factory setting: 550 Ω