Lexing LX-PR-29A-Z User manual

LX-PR-29A-Z Infrared Sensor Instruction
105mm
59mm
88.0mm
105mm
58mm
Summary
Power source: 220-240VAC,50Hz/60Hz
100-130VAC,50Hz/60Hz
All loads:1200W Max.(220-240VAC )
800W Max.(100-130VAC)
Time setting: 10sec-12min(adjustable)
Light-control: <10LUX-2000LUX(adjustable)
Detection range
(22°C)
: 1-8m (radii.)(adjustable)
Detection angle: 360º (ceiling installation)
Installation height: 2.5-4.5m
Working temperature: -10°C-+40°C
Working humidity: <93%RH
Sense motion speed: 0.6-1.5m/s
Sensor´s LED:
1. After power-on for 30 seconds, it enters the normal induction state. During this time, the LED lights flash
once every second.
2. It light once when the unit receives sensing signal.
Specifications
This product is an advanced digitally controlled infrared pyroelectric intelligent sensor
product.This product uses one high-resolution sensor that is almost twice the
sensitivity of a single traditional sensor.It uses the MCU to accurately calculate the
switch information, and accurately controls the relay to be turned on at the zero point
of the sine wave, so that each load is turned on. At the zero point of the sine wave, the
inrush current problem caused by the conventional control mode when the sine wave
high voltage is turned on is avoided, especially the large current damage relay
generated by the large-capacity capacitor under the impact of the high voltage under
the load.
Due to the diversification of current electrical loads, especially LED lamps, energy-saving lamps, and fluorescent lamps
all have capacitors with different capacitances. This is a disaster for relays. Sometimes a 50W LED lamp can generate
surge currents of 80 to 120A. The 10A ordinary relay can only withstand 3 times of the inrush current, and it is likely that
the relay will be broken in a few days or several times. This is why the conventional sensor on the market has a short
life and a small load current.
In order to overcome this problem, this product adopts advanced digital precision calculation to turn on the load when
the sine wave is at zero potential, thus solving the load surge current problem, greatly enhancing the load capacity and
prolonging the service life of the product. The latest control method of mass production sensor technology can easily
control any load. It is a medium and high-end product. Although the cost is increased compared with the conventional
version, the reliability and life of the product are greatly increased. This product is equal to choosing peace of mind, and
choosing safety.
This product has a switching power supply version and a capacitor step-down version. The switching power supply
version has a working voltage of up to 100V-277V and a standby power consumption of <0.5W. In principle, the
capacitive step-down version can only have a single voltage, and the standby power consumption is >0.7W. You should
consider it when choosing a product.
LUX adjustment:
LUX refers to the illuminance of the environment. Adjusting the LUX adjustment knob allows you to choose which
illuminance you want to get the sensor into the induction. Choose the habit that suits you.
Some of the choices in the 20LUX solution are to be illuminated. Some choose 50LUX ambient illumination to be
inductive lighting, and some choose to be inductive lighting at any time, as long as the LUX adjustment knob is
adjusted to the maximum.
Time adjustment:
The time adjustment knob is used to adjust the time after the sensor senses the light, and the user can reasonably
select the delay time after the induction.
Function
Digital precision switching control technology

Sensor information
Height of installation2.5-4.5m
2.5-4.5m
Height of installation2.5-4.5m
2.5-4.5m
8m
360°
8m 1m 1m
1 X High resolution sensor
Detection range(22℃) Detection angle
②TIME: Adjust time setting of load work. Turn clockwise to increase it and turn anti-clockwise to decrease it.
The time setting is about 12min when turn to max, and the time setting is about 10sec when turn to min .
③LUX: Adjust working light. Turn clockwise to increase it and turn anti-clockwise to decrease it. When turn to
min, it will only work below the light-control about 10LUX, when turn to max, it can work any light-control.
Brown L
Blue N
~ in L' Red
load
sensor
①SENS: Adjust detection range. Turn clockwise to increase it and turn anti-clockwise to decrease it. It is 1m
when turn to min, and it is 8m when turn to max.
TIME
+
-
SENS
+
LUX
Knob setting
Connection-wire diagram
ATTENTION: When use this product, please adjust the sensitivity to an appropriate position
you need, please do not adjust the sensitivity to maximum, to avoid the product does not
work normally caused by wrong motion.Because the sensitivity is too high easily detect the
wrong motion by wind blowing leaves & curtains, small animals, and the wrong motion by
interference of power grid & electrical equipment. All those lead the product does not work
normally !
When the product does not work normally, please try to lower the sensitivity appropriately,
and then test it.
out
Brown
Blue
Red
connect L and N with power;
connect L′and N with load.
N
L
L′

(1)Before installing switch off power;
(2)Rotate top cover anti-clockwise and take
off it, tighten off the screws fixing bottom
cover;
(3)Install the bottom cover on selected
position with screw(like①);
(4)According to the connection-wire diagram
connect the power wire and load wire into the
connection line column in sensor;
(5)Button top cover on sensor and rotate it
tighten clockwise(like②), the installing
finished.
Installation instruction
The load don’t work:
a. Please check the power and load connect is correct.
b. Check if the load is good.
c. Check if the show lamp accelerates its speed after detecting.
d. Check if the working light corresponds to the light-control.
The sensitivity is poor:
a. Please check if there is hinder in front of the detection window to effect receiving the signals.
b. Please check if the ambient temperature is too high.
c. Please check if the signals source is in the detection fields.
d. Please check if the installation height corresponds to the height showed in the instruction.
e. Please check if the moving orientation is correct.
The sensor can’t shut the load automatically:
a. Check if there are continual signals in the detection fields.
b. Check if the time setting is set to the longest.
c. Check if the power corresponds to the instruction.
d. Check if the temperature change obviously nears the sensor, such as air condition or central heating etc.
Avoid installing it near air temperature alteration zones such as air condition, central heating, etc.
Considering your safety, please don’t open the cover when you find the hitch after installation.
If there is difference between product and instruction, please refer to product mainly.
Some problem and solved way
Should be installed by electrician or experienced man.
Avoid installing it on the unrest objects.
There shouldn’t be hindrance and moving object in front of the detection window effecting detection.
Note
Warning!
● Please confirm with prefessional installation.
● Please cut off power supply before installation and removal operations.
● Make sure that you have cut off the power for safety purposes.
● Improper operation caused losses, the manufacturer does not undertake any responsibility.
This manual is for the current content programming of this product, there are any changes
and modifications to the manufacturer without notice!
This instruction, without our permission, should not be copied for any other purposes.
Table of contents
Other Lexing Security Sensor manuals

Lexing
Lexing LX-MV-360S10-A User manual

Lexing
Lexing PD-MV1018B User manual

Lexing
Lexing LX-PR-29B-Z User manual

Lexing
Lexing LX-RP-29B User manual

Lexing
Lexing LX39-DZ User manual

Lexing
Lexing LX-MV-400 User manual

Lexing
Lexing LX-MV-360S8-A User manual

Lexing
Lexing LX39-Z User manual

Lexing
Lexing LX-PR-65S-Z User manual