HP
Model Name Combination Unit
Capacity
1)
(Rated)
Cooling
kW
kcal/h
Btu/h
Heating
kW
kcal/h
Btu/h
Input (Rated)
1)
Cooling kW
Heating kW
Power Factor Rated -
Casing Color
Heat Exchanger
Compressor
Type
Piston Displacement cm3/rev
Number of Revolution rev/min
Motor Output x Number
W x No.
Starting Method
Oil Type
Oil Charge
Fan
Type
Motor Output x Number
W
Air Flow Rate(High) m3/min
ft3/min
Drive
Discharge Side / Top
Piping
Connections
Liquid mm(inch)
Gas mm(inch)
Dimensions(W x H x D) mm
mm
Net Weight kg
lbs
Sound Pressure
Level
Cooling dB(A)
Heating dB(A)
Sound Power Level dB(A)
Protection
Devices
High pressure
protection -
High pressure sensor /
High pressure switch
High pressure sensor /
High pressure switch
High pressure sensor /
High pressure switch
Comperssor/ Fan -
Over-heat protection /
Fan driver overload protector
Over-heat protection /
Fan driver overload protector
Over-heat protection /
Fan driver overload protector
Inverter -
Over-heat protection /
Over-current protection
Over-heat protection /
Over-current protection
Over-heat protection /
Over-current protection
Communication Cable
No.xmm
2
(VCTF-SB)
Refrigerant
Refrigerant name
Precharged Amount kg
lbs
Control
Power Supply V, Ø, Hz
Number of maxmum connectable indoor units 2)
Outdoor Units
2_ R410A(50/60Hz)
2. Specifications
nCooling Only 50/60Hz
Notes:
1. Capacities are based on the following conditions:
- Cooling Temperature : Indoor 27°C(80.6°F) DB / 19°C(66.2°F) WB
Outdoor 35°C(95°F) DB / 24°C(75.2°F) WB
- Heating Temperature : Indoor 20°C(68°F) DB / 15°C(59°F) WB
Outdoor 7°C(44.6°F) DB / 6°C(42.8°F) WB
- Piping Length : Interconnected Pipe Length = 7.5m
- Difference Limit of Elevation (Outdoor ~ Indoor Unit) is Zero.
2. The maximum combination ratio is 130%.
3.
Wiring cable size must comply with the applicable local and national codes.
4.
Due to our policy of innovation some specifications may be changed without
notification.
5.
Sound Level Values are measured at Anechoic chamber. Therefore, these
values can be increased owing to ambient conditions during operation.
6.
Power factor could vary less than ±1% according to the operating conditions.
2.5 3 4
ARUV025GSD0 ARUV030GSD0 ARUV040GSD0
7.2 9.2 11.0
6,191 7,911 9,458
24,600 31,400 37,600
- - -
- - -
- - -
1.80 2.10 2.75
- - -
0.93 0.93 0.93
Warm Gray Warm Gray Warm Gray
Wide Louver Plus Wide Louver Plus Wide Louver Plus
Hermetic Motor Compressor Hermetic Motor Compressor Hermetic Motor Compressor
18 24 24
6,000 6,600 6,600
1,500 x 1 2,137 x 1 2,137 x 1
DC Inverter Starting DC Inverter Starting DC Inverter Starting
FVC68D(PVE) FVC68D(PVE) FVC68D(PVE)
670 900 900
Axial Flow Fan Axial Flow Fan Axial Flow Fan
85.4 x 1 124.0 x 1 124.0 x 1
44 60 60
1,553 2,118 2,118
DC INVERTER DC INVERTER DC INVERTER
Side Side Side
9.52(3/8) 9.52(3/8) 9.52(3/8)
15.88(5/8) 15.88(5/8) 15.88(5/8)
870 x 655 x 320 950 x 834 x 330 950 x 834 x 330
34-1/4 × 25-25/32 × 12-19/32 37-13/32 × 32-27/32 × 13 37-13/32 × 32-27/32 × 13
45 59 59
99.2 130 130
50 50 50
- - -
- - -
1.0~1.5 × 2 1.0~1.5 × 2 1.0~1.5 × 2
R410A R410A R410A
1.0 1.4 1.4
2.2 3.1 3.1
Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve
220-240 , 1 , 50 220-240 , 1 , 50 220-240 , 1 , 50
220, 1, 60 220, 1, 60 220, 1, 60
3 5 6