LG LRG3097ST User manual

GAS RANGE
INSTALLATION INSTRUCTIONS
Please read this guide thoroughly
before installation.
To contact LG Electronics, 24 hours a day,
7 days a week:
1-800-243-000 (USA)
1-888-542-2623 (CANADA)
Or visit us on the Web at: us.lge,com (USA)
ca.lge.com (CANADA)
Models
LRG3097ST
LRG3095ST/SB/SW
LRG3093ST/SB/SW
BEFORE YOU BEGIN
Read these instructions completely
and carefully.
Installation of this range must conform with local
codes, or in the absence of local codes, with the
National Fuel Gas Code, ANSI Z223.1/NFPA.54,
latest edition. In Canada, installation must
conform with the current Natural Gas Installation
Code, CAN/CGAB149.1 or the current Propane
Installation Code, CAN/CGA-B149.2, and with
Ioca! codes where applicable. This range has
been design-certified by CSA international
according to ANSI Z21.1, latest edition and
Canadian Gas Association according to
CAN/CGA-I.1 latest edition.
As with any appliance using gas and generating
heat, there are certain safety precautions you
should fol!ow. You wil! find these precautions in
the important Safety information section in your
User's Guide. Read them carefully.
" iMPORTANT - save these instructions
for local electrical inspector's use.
•iMPORTANT-Observe all governing
codes and ordinances.
Note to Installer: Leave these instructionswith
the appliance after installation is completed.
Note to Consumer: Keep the User's Guide and
Installation instructionsfor future reference.
NOTE: This appliance must be properly
grounded.
•The electrical diagram is in an envelope
attached to the back of the range.
=Skill level - installation of this appliance
requires basic mechanical skills.
• Proper installation is the responsibility of the
installer.
• Product failure due to improper installationis
not covered under the Warranty.
•Remove all tape and packaging.
• Make sure the burners are properly seated
and level.
Take the accessory pack out of the oven
and/or drawer.
• Check to be sure that no range parts have
come loose during shipping.
P/NO. MFL62177701

INSIA/LAIIONINSTRUCTIONS
READ ALL iNSTRUCTiONS BEFORE iNSTALLATiON
INSTALLATION SAFETY INSTRUCTIONS
BEFORE YoU BEGIN
Remove all tape and packing materials before using the range. Dispose all plastic bags after
unpacking the range. Never allow children to play with packing materials.
IMPORTANT SAFETY INSTRUCTIONS
Read these instructions completely and carefully. Improper installation, adjustment, alteration, service
or maintenance can cause injury or property damage. Refer to this manual. For assistance or
additional information, consult a qualified installer, service agency, manufacturer (dealer) or the gas
supplier.
_, WARNING: Iftheinformationin
this manual is not followed exactly, a fire or
explosion may result causing property damage,
personal injury or death.
- DO NOT store or use combustible materials,
gasoline or other flammable vapors and liquids in
the vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
. DO NOT try to light any appliance.
• DO NOT touch any electrical switch.
. DO NOT use any phone in your building.
. Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
. If you cannot reach your gas supplier, call the
fire department.
lnStallation and service must be performed by a'_
ualified installer, service agency or the gas J
upplier 1

INSTALLATIONINSIRUCIIONS
READ ALL INSTRUCTIONS BEFORE INSTALLATION
iNSTALLATiONSAFETY iNSTRUCTiONS
WARNING!
(_ •ALL RANGES CAN TiP
oiNJURY TO PERSONS
COULD RESULT
•iNSTALL ANTI=TIP DEVICES
PACKED WITH RANGE
oSEE iNSTALLATiON
°DO NOT step or sit on the door. Install the
Anti-Tip Bracket packed with range.
- The range could be tipped and injury might result
from spilled hot liquid, food, or the range itself.
- If the range is pulled away from the wall for
cleaning, service, or any other reason, ensure that
the Anti-Tip Device is properly reengaged when
the range is pushed back against the wall.
All ranges can tip and injury could result. To prevent
accidental tipping of the range, attach an approved
Anti-Tip device to the wall. (See "INSTALLING THE
ANTFTIP DEVICE" in this manual.) To check if the
device is installed and engaged properly, carefully
tip the range forward. The Anti-Tip device should
engage and prevent the range from tipping over.
If you pull the range out from the wall for any
reason, make sure the AntFTip device is engaged
when you push the range back against the wall.
&WARNING
• NEVER reuse old flexible connectors. The use of
old flexible connectors can cause gas leaks and
personal injury. Always use NEW flexible
connectors when installing a gas appliance.
- Your range must be installed by a qualified
installer.
. Your range should be electrically grounded in
accordance with local codes or, in the absence of
local codes, in accordance with the National
Electrical Code (ANSVNFPA 70, latest edition). In
Canada, electrical grounding must comply with the
current CSA C22.1 Canadian Electrical Code Part
1 and/or local codes. See "ELECTRICAL
CONNECTIONS" in this manual.
• Before installing your range on linoleum or any
other synthetic floor covering, make sure the floor
covering can resist 180°F (82°C) without shrinking,
warping or discoloring. Do not install the range
over carpeting unless a sheet of 1/4" thick plywood
or similar insulator is placed between the range
and carpeting.
• Make sure the wall coverings around the range
can resist heat generated by the range up to
200°F (93°C).
• Leak testing of the appliance shall be conducted
according to the manufacturer's instructions.
• Avoid placing cabinets above the range. To
minimize the hazard caused by reaching over the
open flames of operating burners, install a
ventilation hood over the range that projects
forward at least 5" beyond the front of the
cabinets.
• The ventilation hood must be constructed of sheet
metal not less than 0.0122" thick. Install above
the cooktop with a clearance of not less than 1/4"
between the hood and the underside of the
combustible material or metal cabinet.
The hood must be at least as wide as the
appliance and centered over the appliance.
Clearance between the cooking surface and
the ventilation hood surface MUST NEVER BE
LESS THAN 24 INCHES.
EXCEPTION: Installation of a listed microwave
oven or cooking appliance over the cooktop shall
conform to the installation instructions packed with
that appliance.
• If cabinets are placed above the range, allow a
minimum clearance of 30" between the cooking
surface and the bottom of unprotected cabinets.

INSIA//AIION INSTRUCTIONS
READ ALL INSTRUCTIONS BEFORE INSTALLATION
INSTALLATION SAFETY INSTRUCTIONS (continued)
_, WARNING
•If a 30" clearance between cooking surface and
overhead combustible material or metal cabinets
cannot be maintained, protect the underside of
the cabinets above the cooktop with not less than
1/4" insulating millboard covered with sheet metal
not less than 0.0122" thick. Clearance between
the cooking surface and protected cabinets MUST
NEVER BE LESS THAN 24 INCHES.
•The vertical distance from the plane of the
cooking surface to the bottom of adjacent
overhead cabinets extending closer than 1" to the
plane of the range sides must not be less than
18". (See the Dimensions and Clearances
illustration in this manual.)
,& CAUTION
• Items of interest to children should not be stored in
cabinets above a range or on the backsplash of a
range--children climbing on the range to reach
items could be seriously injured.
. DO NOT attempt to operate the oven of this range
during a power failure.
IN THE COMMONWEALTH OF MASSACHUSETTS
• This product must be installed by a licensed
plumber or gas fitter.
• When using ball type gas shut-off valves, they shall
be the T-handle type.
• When using a flexible gas connector, it must not
exceed 3 feet in length.
PREPARING FOR INSTALLATION
TOOLS YOU WILL NEED
Phillips screwdriver
,.=-1
Flat-blade screwdriver
Pencil and ruler
Open-end or
adjustable wrench
Pipe wrench(2)
(one for support)
Level
J
MATERIALS YOU MAY NEED
o
o
Gas line shut-off valve
Pipe joint sealant that resists action of natural and LP
gases.
.Flexible metal appliance connector (3/4" or 1/2" NPT
x 1/2" I.D.)
Never use an old connector when installing a new
range.
• Flare union adapter for connection to gas supply line
(3/4" or 1/2" NPTx 1/2" I.D.)
• Flare union adapter for connection to pressure
regulator on range (1/2" NPT x 1/2" I.D.)
•Liquid leak detector or soapy water.
•Lag bolt or 1/2" O.D. sleeve anchor (for concrete
floors only).

INSTAllAIIONINSIRUCTIONS
DIMENSIONS AND CLEARANCES
Provide proper clearances between the range and
adjacent combustible surfaces. These dimensions
must be met for safe use of your range. The location
of the electrical outlet and pipe opening (see "GAS
PIPE AND ELECTRICAL OUTLET LOCATIONS")
may be adjusted to meet specific requirements.
The range may be placed with 0" clearance (flush) at
the back wall.
fINSTALLATION
CLEARANCES
18 _''
Minimum to
O cabinets on
either side of
the range
]Minimum
clearance
to left wall
Minimum
r 1
I
°I°
_5"
Minimum clearance to
right wall
t
Maximum depth
for cabinets
above
coutertops
OII
To cabinets
below cooktop
and at the range
back J
fDIMENSIONS I Depth with door ctosed (includes door handle)
Height
477/le "
Depth with door open.
471/4" J

INSTA//AilONiNSTRUCTiONS
LOCATION
Do not locate your range where it may be subject
to strong drafts. Any openings in the floor or wall
behind the range should be sealed. Make sure the
openings around the base of the range that
supply fresh air for combustion and ventilation
are not blocked by carpeting or woodwork.
Your range, like many other household units, is heavy
and can be installed on soft floor coverings such as
cushioned vinyl or carpeting. Use care when moving
the range on this type of flooring.
It is recommended that the following simple and
inexpensive instructions be followed to protect your
floor.
When the floor covering ends at the front of the range
the area that the range will be installed on should be
built up with plywood to the same level or higher than
the floor covering. This will allow the range to be moved
for cleaning and servicing, as well as proper air flow to
the range.
Also, make sure the wall covering can resist 180°F
(82°C). See the "INSTALLATION SAFETY
INSTRUCTIONS" (included in this manual).
Make sure the wall coverings around your range can
resist the heat generated (up to 200°F/93°C) by the
range. See the "INSTALLATION SAFETY
INSTRUCTIONS" (included in this manual).

INSTAllAIIONINSIRUCTIONS
GAS PIPE AND ELECTRICAL OUTLET LOCATIONS
f
O
Recommended area for 120V
outlet on rear wall and area for
through-the wall connection of
pipe stub and shut-off valve.
161/2" 181/3"
Recommended area for
through-the floor connection
of pipe stub and shut-off valve.
1. PROVIDE ADEQUATE GAS SUPPLY
Your range is designed to operate at a pressure of
5" of water column on natural gas or 10" of water
column on LP.
Make sure you are supplying your range with the type
of gas for which it is configured.
This range is convertible for use on natural or
LP gas. When using this range on LP gas,
conversion must be made by a qualified LP installer
before attempting to operate the range.
For proper operation, the pressure of natural gas
supplied to the regulator must be between 5" and 13"
of water column.
For LP gas, the pressure supplied to the regulator must
be 10" and 13" of water column.
When checking for correct operation of the regulator,
the inlet pressure must be at least 1" more than the
operating (manifold) pressure as given above.
The pressure regulator located at the inlet of the
range must remain in the supply line regardless of wich
type of gas is being used.
A flexible metal appliance connector used to connect
the range to the gas supply line should have an I.D. of
5/8" and a max of 5ft.
In Canada, flexible connectors must be single wall metal
connectors less than 6 feet in length.

iNSla[[aliONiNSIRUcliONS
2. CONNECTTHE RANGETO
Shut off the range gas supply valve before
removing the old range and leave it off until the
new hook=up has been completed.
Because hard piping restricts movement of the range,
the use of a CSA International=certified flexible metal
appliance connector should be used unless local
codes require a hard-piped connection.
NEVER reuse an old connector when installing a new
range.
To protect against gas leaks, use a qualified pipe
joint sealant on all external threads.
OInstall male 1/2" or 3/4" flare union adapter to the
NPT internal thread of the manual shut=off valve,
taking care to back-up the shut-off valve to keep it
from turning.
GAS
_ Install male 1/2" flare union adapter to the 1/2"
NPT internal thread at inlet of presure regulator.
Use a backup wrench on the presure regulator
fitting to prevent damage.
_ Connect flexible metal appliance connector to the
adapter on the range. Position range to permit
connection at the shut=off valve.
OWhen all connections have been made, be sure
all range controls are in the off position and then
on the range gas supply valve. Check for gas leaks
by using a liquid leak detector at all joints and
connections.
kWARNING!
DO NOT USE A FLAME TO CHECK FOR GAS
LEAKS,
WARNING!
Isolate the range from the gas supply system by
closing its individual shut-off valve during any
pressure testing of the gas supply system at test
pressures equal to or less than 1/2" psig(3.5kPa).
FLEXIBLE CONNECTORHOOKUP
f
Adapter
Pressure regulator
_1_[_ Flex connector
(6 ft. max.)
-------- Adapter
Installer: Inform the
consumer of the
location of the gas _ Gas shut-off valve
shut-off valve, 1/2" or 3/4"
Gas pipe

INSTAllAIIONINSIRUCTIONS
3. ELECTRICALCONNECTIONS
ELECTRICAL REOUIREMENTS
120 Volt, 60 Hertz, properly grounded dedicated circuit protected by a 15 or 20 Amps circuit breaker or slow
blow fuse.
GROUNDING
IMPORTANT: FOR PERSONAL SAFETY, THIS APPLIANCE MUST BE PROPERLY GROUNDED.
The power cord of this appliance is equipped with a
3-prong (grounding) plug which mates with a standard
3-prong grounding wall receptacle to minimize the
possibility of electric shock hazard from this
appliance.
The customer should have the wall receptacle and
circuit checked by a qualified electrician to make sure
the receptacle is properly grounded.
Where a standard two-prong wall receptacle is
encountered, it is the personal responsibility and
obligation of the customer to have it replaced with a
properly grounded three-prong wall receptacle.
DO NOT, UNDER ANY CIRCUMSTANCES, CUT OR
REMOVE THE THIRD (GROUND) PRONG FROM
THE POWER CORD.
A word about GFCI's - GFCI's are not required or
recommended for gas range receptacles.
Ground Fault Circuit Interrupters (GFCI's) are devices
that sense leakage of current in a circuit and
automatically switch off power when a threshold
leakage level is detected. These devices must be
manually reset by the consumer. The National
Electrical Code requires the use of GFCI's in kitchen
receptacles installed to serve countertop surfaces.
Performance of the range will not be affected if
operated on a GFCI-protected circuit but occasional
nuisance can occur.
fPREFERRED
METHOD
nsure proper ground
ists before use
CAUTION:
The customer should have the circuit checked by a
qualified electrician to make sure the receptacle is
properly grounded.
DO NOT use an adapter plug because disconnecting
of the power cord places undue strain on the adapter
and leads to eventual failure of the adapter ground
terminal.
The installation of appliances designed for mobile
home installation must conform with the Manufactured
Home Construction and Safety Standard, Title 24
CFR, Part 3280 (formerly the Federal Standard for
Mobile Home Construction and Safety, Title 24, HUD,
Part 280) or, when such standard is not applicable,
the Standard for Manufactured Home Installations,
latest edition (Manufactured Home Sites,
Communities and Set-Ups), ANSI A225.1, latest
edition, or with local codes. In Canada, mobile home
installation must be in accordance with the current
CAN/CSA Z240/MH Mobile Home Installation Code.
4. SEAL THE OPENINGS
Seal any openings in the wall and floor after electrical and gas supplies are completed

INSIAllAIION INSIRUCIIONS
5. ASSEMBLE THE SURFACE BURNERS
CAUTION
DO NOT operate the burners without all parts in
place.
Place the burner caps and heads on the cooktop.
Make sure that the caps and heads are placed in the
correct locations. There is one small, one medium,
one large and one extra large burner head and cap.
fOval (Center) Burner
Head/Cap Assembly
! _ Small burner
S-_ %- :_._ ,, _ head and cap
..........
Med um burner I A i _ s----_
neao an(] cap/ m I _ ..... _-_-
@ _ T_J i (°ns°me (°ns°me
' models) models)
I................
Large burner Front of range Extra large burner
head and cap head and cap
Hole _ I .....
I I
Electrode
Make sure the hole in the burner head is positioned
over the electrode.
6. CHECK IGNITION OF SURFACE BURNERS
ELECTRIC IGMTION
Select a top burner knob and simultaneously push in
and turn to the "LITE" position. You will hear a clicking
sound indicating proper operation of the spark
module.
Once the air has been purged from the supply lines,
burner should ignite within 4 seconds.
After burner ignites, rotate knob out of the "LITE"
position. Try each burner in succession until all
burners have been checked.
OUALITY OF FLAMES
The combustion quality of burner flames needs to be
confirmed visually.
A Yellow flames--Call for service
B Yellow tips on outer cones--
It is normal for LP gas
C Soft blue flames--
It is normal for natural gas
With LP gas, some yellow tipping on outer cones is
normal.

INSTAllAIIONINSIRUCTIONS
7. ADJUST THE SURFACE BURNER LOW
FLAME(SIMMER) SETTING.
1) Light all surface burners.
2) Turn the knob on the burner being adjusted to
"LO".
3)
4)
Remove knob.
Insert a small, flat bladed screwdriver into the valve
shaft as shown in Fig. 1.
On right front valve for model LRG3097S there is a
secondary adjustment for the low flame for the
outer burners.
Using a small, flat bladed screwdriver insert into
the hole next to the valve stem to adjust outer
flame as shown in Fig. 2.
Turn the adjustment screw until the flame reaches
the desired size.
5) Replace the knob.
Note: Hold the valve shaft with one hand while turning
the screw for adjustment with the other.
f
Center adjustment screw Adjustment screw next to
the valve shaft
Fig. 1 Fig. 2
6) Test The Flame Stability.
Test 1: Turn the knob from "HI" to "LOW" quickly.
If the flame goes out, increase the flame size and test
again.
Test 2: With the burner on a "LOW" setting, open and
close the oven door quickly. If the flame is
extinguished by the air currents created by the door
movement, increase the flame height and test again.
7) Repeat steps 1-5 for each surface burner.

INSIAllAIION INSTRUCIIONS
8. CHECK OPERATION OF BAKE/BROIL BURNERS
To check ignition of the Bake burner follow the
steps below: To check ignition of the Broil burner follow the steps
below:
1) Remove all packing from inside the oven cavity.
2) Press "Bake" (350 will be shown in the display).
3) Press Start
1) Press "Broil" ("Hi" will be shown in the display).
2) Make sure the door is closed.
3) Press Start
It may take between 30 and 90 seconds for the
burner to start heating. It may take between 30 and 90 seconds for the burner to
start heating.
NOTE: Do not try and light either the bake or broil
burners during a power outage. The range has an
electrical ignition system and can not be used
without power.
9. AIR SHUTTER ADJUSTMENT FOR BAKE AND BROIL
BURNERS.
The range comes from the factory with air shutters adjusted for proper air flow for natural gas. If converted to
LP follow the instructions provided in the conversion kit to properly adjust the air shutters. LP conversion must be
performed by a qualified technician.

INSIAllMION INSTRUCTIONS
10. INSTALLING THE ANTI-TIP DEVICE
LOCATING THE BRACKET USING THE
TEMPLATE.
f
Anti-tip _late
J
An Anti-tip bracket is packaged with template.
The instructions include necessary information to
complete the installation.
Read and follow range installation instruction sheet
(template).
11. LEVELING THE RANGE
WARNING
, Range must be secured with an approved Anti-
Tip device.
- Unless properly installed, the range could be
tipped by you or achild standing, sitting or
leaning on an open door,
* After installing the Anti-Tip device, verify that
it is in place by carefully attempting to tilt the
range forward.
,This range has been designed to meet all
recognized industry tip standards for all
normal conditions,
, The installation of the Anti-Tip device must
meet all local codes for securing the
appliance,
•The use of this device does not preclude
tipping of the range when not properly
installed,
f
f
Leg leveler
range
Spirit level
J
O Install the oven shelves in the oven and locate the
range where it will be installed.
_1 Check for levelness by placing a spirit level or a
cup, partially filled with water, on one of the oven
shelves. If using a spirit level, take two readings--
with the level placed diagonally first in one
direction -(0 and then the other -C©.
_! Remove the drawer. See the "CARE AND
CLEANING OF THE RANGE" section in the
User's Guide. The front leveling legs can be
adjusted from the bottom and the rear legs can be
adjusted from the bottom.
_1 Use an open-end or adjustable wrench to adjust
the leveling legs until the range is level.
J
13(_

INSIAllAIION INSTRUCIIONS
WHEN ALLHOOKUPS ARE COMPLETE
Make sure all controls are left in the off position. Make sure the flow of combustion and ventilation air
to the range is unblocked.
CONVERTING TO LP GAS
(OR CONVERTING BACK TO NATURAL GAS FROM LP)
This range leaves the factory set for use with
natural gas. The convertion to LP gas must be
performed by a qualified LP gas installer when
converting to LP gas.
The conversion instructions and LP orifices can be
found attached to the range next to the oven valve.
Keep these instructions and the orifices in case you
want to convert back to natural gas.
Other manuals for LRG3097ST
9
This manual suits for next models
6
Table of contents
Other LG Range manuals

LG
LG LSDS6338F.BRSLSTD User manual

LG
LG LDG4313 Series User manual

LG
LG LSSE3026 Series User manual

LG
LG LSSE3027 Series User manual

LG
LG LREL6325 Series User manual

LG
LG LRG3021ST User manual

LG
LG LRE3021ST User manual

LG
LG LRE30757ST/01 User manual

LG
LG LREL6323 Series User manual

LG
LG LRE3012S Use and care manual