manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. LI-COR
  6. •
  7. Lighting Equipment
  8. •
  9. LI-COR 6400-18A Quick start guide

LI-COR 6400-18A Quick start guide

Popular Lighting Equipment manuals by other brands

Life 39.9F70020C quick start guide

Life

Life 39.9F70020C quick start guide

EuroLite LED ML-20 user manual

EuroLite

EuroLite LED ML-20 user manual

LIGMAN OD-50141 installation manual

LIGMAN

LIGMAN OD-50141 installation manual

Home Accents Holiday 1002461144 instructions

Home Accents Holiday

Home Accents Holiday 1002461144 instructions

Experia IRiS Ripple Light instruction manual

Experia

Experia IRiS Ripple Light instruction manual

Erco Gecko Mounting instructions

Erco

Erco Gecko Mounting instructions

Inter-lux ZTA.100.Surface Installation and maintenance instructions

Inter-lux

Inter-lux ZTA.100.Surface Installation and maintenance instructions

Whelen Engineering Company TN Series installation guide

Whelen Engineering Company

Whelen Engineering Company TN Series installation guide

IKEA BJÖRKSPIREA manual

IKEA

IKEA BJÖRKSPIREA manual

Toolland PM 6640 instruction manual

Toolland

Toolland PM 6640 instruction manual

GTD GTD-LP200 user manual

GTD

GTD GTD-LP200 user manual

LIVARNO home 1105-W-UK manual

LIVARNO home

LIVARNO home 1105-W-UK manual

ProLights EclPar IPMFC user manual

ProLights

ProLights EclPar IPMFC user manual

Velvet EVO Series user manual

Velvet

Velvet EVO Series user manual

IDTOLIGHT GENT installation instructions

IDTOLIGHT

IDTOLIGHT GENT installation instructions

MAYTONI S35 installation manual

MAYTONI

MAYTONI S35 installation manual

MaxLite MLFP14DP4535 user manual

MaxLite

MaxLite MLFP14DP4535 user manual

SLV Elektronik 550621 instruction manual

SLV Elektronik

SLV Elektronik 550621 instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

1. Install the 6400-17 or 6400-24 Chamber as per the
instructions included with the chamber.
2. Remove the 4 Phillips head screws on the bottom of
the RGB Light Source. Make sure that there is a
Propafilm covering over the aperture on top of the
chamber top plate. With the Propafilm facing the
bottom of the RGB Light Source, attach the chamber
top plate to the bottom of the light source using the 4
Phillips head screws (Figure 1).
3. Connect one end of the gray control cable to the
Control connector on the side of the light source, and
the other end to the 37-pin Auxiliary connector on the
LI-6400/LI-6400XT console (Figure 2).
4. Connect one end of the power supply cable to the light
source. Connect the power supply to mains power
(Figure 2). When first plugged in, the RGB light
source cooling fan may run momentarily; this is
normal. The power supply will automatically adjust
for varying voltage inputs (100-240VAC, 1.4A max.,
50-60 Hz). The power supply can be attached to the
LI-6400/LI-6400XT console using the supplied Velcro
kit, if desired (Figure 3).
The 6400-18A RGB Light Source is designed to be used
with the 6400-17 Whole Plant Arabidopsis (WPA) Cham-
ber, the 6400-24 Bryophyte Chamber, or with the
LI-6400XT and any clear-topped chamber. The LED
calibration is retained in the light source, making it
possible to switch from instrument to instrument without
the need to enter calibration constants. The red, green and
blue LEDs can be independently adjusted to allow users to
select any desired color combination. Photosynthetic
response differs with illumination wavelength, and is
explained in more detail in Application Note 5.
The assembly requires a Phillips head screwdriver, and
takes about 15 minutes to complete.
■Follow these steps to install the 6400-18A:
6400-18A RGB Light Source
Continued on next page
Installation and Operational Instructions
PPS-258
Figure 2. Connect the gray control cable to the LI-6400/LI-6400XT
console, and the power cable to the AC power supply.
CHAMBER
SAMPLE
REF
INLET
IRGA
!
UNPLUG BATTERIES
BEFORE SERVICING.
RS-232
AUXILIARY
Ol
CHGPWR
BA
TTERY
INPUT-12VDC
CHARGE-14.8VDC0.65AMAX.
INPUT
17-24VDC
72W
OUTPUT
14.8VDC
4.0AMAX.
MODEL6400-70
escape
enterenter
Q
A
Z
1
!@
2
#
3
$
4
SDF
%
5
^
6
&
7
GHJK
*
8
(
9
)
0
_
-
+
=
L;
:"
'
\
space
ctrl
WERTYUIOP{
[
}
]
~
|
shift
XCVBNM,
<>
.
?
/
shift
LI-6400 Portable Photosynthesis System
f1f2f3f
4f5
labels
home
endpgdn
pguphome
endpgdn
pgup
WelcomeConfigCalibNewUtility
LI-6400PhotosynthesisSystem
/User10%full
12.00V
OPEN5.00
MenuMenu
TueJun25200213:31:56
MenuMsmntsMenu
labels
6400-18A
AC Power Supply
To Mains Power
+15V4.8A
Figure 1. Attach the chamber top plate to the bottom of the RGB
Light Source using 4 Phillips head screws.
PPS258, Rev. 2
11/14
Configure the Software
5. The 6400-18A requires OPEN version 6.1 or above.
OPEN 6.1 can be installed on 200 MHz (previous version
OPEN 5.x) or 400 MHz (previous version OPEN 6.x)
digital boards. Older boards require a digital board
upgrade. Contact LI-COR for more details.
6. To complete the installation, choose the Config Menu
(f2) from OPEN’s main screen. Highlight New and press
Enter. Scroll down and choose the 6400-18 RGB Source.
Choose a chamber, adjust settings as needed, and press N
to save the configuration under a new name. See the
LI-6400/LI-6400XT Instruction Manual, Section 8, Light
Sources and Sensors, for more information.
1. Choose
New
from the Config Menu...
2. Scroll down to 6400-18 RGB Source...
3. Choose 6400-17 Whole Plant or 6400-24 Bryophyte Chamber.
© 2014, LI-COR, Inc. LI-COR is a registered trademark of LI-COR, Inc.
LI-COR Ltd., United Kingdom
Serving Denmark, Finland, Ireland, Norway, Sweden, and UK.
LI-COR Biosciences UK Ltd.
St. John’s Innovation Centre
Cowley Road
Cambridge
CB4 0WS
United Kingdom
Phone: +44 (0) 1223 422102
Fax: +44 (0) 1223 422105
envsales-UK@licor.com • envsupport-UK@licor.com
LI-COR Biosciences - Global Headquarters
4647 Superior Street
Lincoln, Nebraska 68504
Phone: +1-402-467-3576
Toll free: 800-447-3576
Fax: +1-402-467-2819
envsales@licor.com • envsupport@licor.com • www.licor.com/env
Regional Offices
LI-COR GmbH, Germany
Serving Andorra, Albania, Belarus, Cyprus, Estonia, Germany,
Iceland, Latvia, Lithuania, Liechtenstein, Malta, Moldova, Monaco,
San Marino, Ukraine, and Vatican City.
LI-COR Biosciences GmbH
Siemensstraße 25A
61352 Bad Homburg, Germany
Phone: +49 (0) 6172 17 17 771
Fax: +49 (0) 6172 17 17 799
envsales-gmbh@licor.com • envsupport-gmbh@licor.com
5. and press
N
to save as a new configuration.
4. Adjust settings as needed...
Figure 3. Affix the power supply to the console, if desired.