Lienuis OL20-D068C User manual

USER MANUAL
MODEL:OL20-D068C
R

USER MANUAL
CONTENTS
1
2
3
4
5
6
7
8
9
10
BEFORE YOU BEGIN.....................................................1
IMPORTANT SAFETY TIPS..........................................3
PRODUCT OVERVIEW...................................................7
INSTALLATION..............................................................8
OPERATION...................................................................10
MAINTENANCE............................................................15
TROUBLE SHOOTING..................................................17
DECOMMISSIONING....................................................18
SAFETY PRECAUTIONS..............................................19
CUSTOMER SERVICE.................................................20

BEFORE FIRST USE:
To prevent any internal damage, it is very important to
keep refrigeration units (like this one) upright throughout
their journey. Please leave it standing upright and outside
the box for 24 HOURS before plugging it in.

BEFORE YOU BEGIN
Please read the operating instructions carefully before using your dehumidifier for the first time.
SYMBOLS FROM THE UNIT AND USER MANUAL
This unit uses a flammable refrigerant.
If refrigerant leaks and comes in contact with fire or heating part,
it will create harmful gas and there is risk of fire.
Read the USER MANUAL carefully before operation.
Further information is available in the USER MANUAL,
SERVICE MANUAL, and the like.
Service personnel are required to carefully read the USER
MANUAL and SERVICE MANUAL before operation.
The dehumidifier is used to remove excessive moisture from the air. The resulting reduction in
relative humidity protects buildings and their contents from the adverse effects of excess humidity.
The environmentally friendly R134a is used as the refrigerant. R134a has no damaging influence on
the ozone layer (ODP), a negligible greenhouse effect (GWP) and is available worldwide. Because
of its efficient energy properties, R134a is highly suitable as a coolant for this application.
Special precautions must be taken into consideration due to the coolant's high flammability.
1
1

2
1.2 THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR SAFETY
FAILURE TO ABIDE BY THIS WARNING COULD RESULT IN AN EXPLOSION,
DEATH, INJURY AND PROPERTY DAMA
This appliance is intended to be used by expert or trained users in shops, in light industry
and on farms, or for commercial use by lay persons.
This appliance can be used by children aged from 8 years and above and persons with
reduced physical, sensory or mental capabilities or lack of experience and knowledge if
they have been given supervision or instruction concerning use of the appliance in a safe
way and understand the hazards involved. Children shall not play with the appliance.
Cleaning and user maintenance shall not be made by children without supervision.
The unit is designed only for use with R-134a(propane) gas as the designated refrigerant.
The refrigerant loop is sealed. Only a qualified technician should attempt to service!
Do not discharge the refrigerant into the atmosphere.
R-134a (propane) is flammable and heavier than air.
It collects first in low areas but can be circulated by the fans.
If propane gas is present or even suspected, do not allow untrained personnel to attempt
to find the cause.
The propane gas used in the unit has no odor.
The lack of smell does not indicate a lack of escaped gas.
If a leak is detected, immediately evacuate all persons from the store, ventilate the room
and contact the local fire department to advise them that a propane leak has occurred.
Do not let any persons back into the room until the qualified service technician has
arrived and that technician advises that it is safe to return to the store.
No open flames, cigarettes or other possible sources of ignition should be used inside
or in the vicinity of the units.
Component parts are designed for propane and non-incentive and non-sparking.
Component parts shall only be replaced with identical repair parts.

IMPORTANT SAFETY TIPS
IMPORTANT NOTICE FOR FIRST TIME USE
Be sure the dehumidifier is properly grounded. To minimize shock and
fire hazards, proper grounding is important. This power cord is
equipped with a three-prong grounding plug for protection against
shock hazards.
Your dehumidifier must be used in a properly grounded wall socket.
If your wall socket is not adequately grounded or protected by a time
delay fuse or circuit breaker, have a qualified electrician install the
proper socket.
Avoid fire hazard or electric shock. Do not use an extension cord or an
adapter plug.
Never unplug the dehumidifier by pulling on the power cord. Always
grip the plug firmly and pull straight out from the receptacle.
Do not pinch, bend, or knot the power cord.
SAVE THESE INSTRUCTIONS / FOR HOUSEHOLD USE ONLY
Your safety is the most important thing we concerned!
Please read this manual carefully and fully understand before operating your
dehumidifier.
2.1 OPERATIONAL PRECAUTIONS
WARNING- to reduce the risk of fire, electric shock or injury to persons or property:
If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or
similarly qualified persons in order to avoid a hazard.
The A-weighted sound pressure level is below 36 dB.
The appliance shall be disconnected from its power source during maintenance.
Always operate the unit from a power source of equal voltage, frequency and rating as
indicated on the product identification plate.
Alwaysusea power outlet thatisgrounded.
Unplug the power cord when cleaning or when not in use.
2
3

4
Do not operate with wet hands. Prevent water from spilling onto the unit.
Do not immerse or expose the unit to rain, moisture or any other liquid.
Do not leave the unit running unattended. Do not tilt or turn over the unit.
Do not unplug while the unit is operating.
Do not unplug by pulling on the power cord.
Do not use an extension cord or an adapter plug.
Do not put objects on the unit.
Do not climb or sit on the unit.
Do not insert fingers or other objects into the air outlet.
Do not touch the air inlet or the aluminum fins of the unit.
Do not operate the unit if it is dropped, damaged or showing signs of product malfunction.
Do not clean the appliance with any chemicals.
Ensure the unit is far away from fire, inflammable, or explosive objects.
The unit shall be installed in accordance with national wiring regulations.
Do not use means to accelerate the defrosting process or to clean, other than those recommended
by the manufacture.
The appliance shall be stored in a room without continuously operation sources (for example: open
flames, an operating gas appliance or an operating electric heater).
The appliance shall be stored so as to prevent mechanical damage from occurring.
Do not piece or burn, even after use.
Be aware that refrigerants may not contain an odour.
Pipe-work shall be protected from physical damage and shall not be installed in an unventilated
space, if that space is smaller than 4m².
Compliance with national gas regulations shall be observed.
Keep any required ventilation openings clear of obstruction.
The appliance shall be stored in a well-ventilated area where the room size corresponds to the room
area as specified for operation.
Any person who is involved with working on or breaking into a refrigerant circuit should hold a
current valid certificate from an industry-accredited assessment authority, which authorizes
their competence to handle refrigerants safely in accordance with an industry, recognized a
ssessment specification.
Servicing shall only be performed as recommended by the equipment manufacturer.
Maintenance and repair requiring the assistance of other skilled personnel shall be carried
out under the supervision of the person competent in the use of flammable refrigerants.
If you don't understand something or need help, please contact the Lienuis services

5
2.2 SAFETY PRECAUTIONS ON SERVICING
Please follow these warnings when to undertake the following when servicing a dehumidifier
with R134a.
Prior to beginning work on systems containing flammable refrigerants, safety checks are necessary to
ensure that the risk of ignition is minimized. For repair to the refrigerating system, the following
precautions shall be complied with prior to conducting work on the system.
Work shall be undertaken under a controlled procedure so as to minimize the risk of a flammable gas
or vapor being present while the work is being performed.
All maintenance staff and others working in the local area shall be instructed on the nature of work
being carried out. Work in confined spaces shall be avoided. The area around the workspace shall be
sectioned off. Ensure that the conditions within the area have been made safe by control of flammable
material.
The area shall be checked with an appropriate refrigerant detector prior to and during work, to ensure
the technician is aware of potentially flammable atmospheres. Ensure that the leak detection
equipment being used is suitable for use with flammable refrigerants, i.e. no sparking, adequately
sealed or intrinsically safe.
If any hot work is to be conducted on the refrigeration equipment or any associated parts, appropriate
fire extinguishing equipment shall be available to hand. Have a dry powder or CO2fire extinguisher
adjacent to the charging area.
No person carrying out work in relation to a refrigeration system which involves exposing any pipe
work that contains or has contained flammable refrigerant shall use any sources of ignition in such
a manner that it may lead to the risk of fire or explosion. All possible ignition sources, including
cigarette smoking, should be kept sufficiently far away from the site of installation, repairing,
removing and disposal, during which flammable refrigerant can possibly be released to the
surrounding space. Prior to work taking place, the area around the equipment is to be surveyed to
make sure that there are no flammable hazards or ignition risks. “No Smoking” signs shall be
displayed.
Ensure that the area is in the open or that it is adequately ventilated before breaking into the system or
conducting any hot work. A degree of ventilation shall continue during the period that the work is
carried out. The ventilation should safely disperse any released refrigerant and preferably expel it
externally into the atmosphere.
①Checks to the area
②Work procedure
③General work area
④Checking for presence of refrigerant
⑤Presence of fire extinguisher
⑥No ignition sources
⑦Ventilated area

6
⑧Checks to the refrigeration equipment
⑨Checks to electrical devices
Where electrical components are being changed, they shall be fit for the purpose and to the correct
specification. At all times the manufacturer’s maintenance and service guidelines shall be followed.
If in doubt consult the manufacturer’s technical department for assistance.
The following checks shall be applied to installations using flammable refrigerants:
– The charge size is in accordance with the room size within which the refrigerant containing parts
are installed;
– The ventilation machinery and outlets are operating adequately and are not obstructed;
– If an indirect refrigerating circuit is being used, the secondary circuit shall be checked for the
presence of refrigerant;
– Marking to the equipment continues to be visible and legible. Markings and signs that are illegible
shall be corrected;
– Refrigeration pipe or components are installed in a position where they are unlikely to be exposed
to any substance which may corrode refrigerant containing components, unless the components are
constructed of materials which are inherently resistant to being corroded or are suitably protected
against being so corroded.
Repair and maintenance to electrical components shall include initial safety checks and component
inspection procedures. If a fault exists that could compromise safety, then no electrical supply shall
be connected to the circuit until it is satisfactorily dealt with. If the fault cannot be corrected
immediately but it is necessary to continue operation, an adequate temporary solution shall be used.
This shall be reported to the owner of the equipment so all parties are advised.
Initial safety checks shall include:
-Those capacitors are discharged: this shall be done in a safe manner to avoid possibility of sparking;
-That there no live electrical components and wiring are exposed while charging, recovering or
purging the system;
-That there is continuity of earth bonding.

PRODUCT OVERVIEW
3
7
3.1 Parts Diagram FRONT
BACK
Front shell
Back shell
Handle
Control Panel
Air Outlet
Water tank
Air filter
Casters

INSTALLATION
4
8
4.1 LOCATION
WARNING
NOTE
1.Place the unit on a firm, level surface in an area with at least 30cm of free space around it
to allow for proper air circulation.
2.Never install the unit where it could be subject to:
Heat sources such as radiators, heat registers, stoves or other products that products that
produce heat.
In an area where oil or water may be splashed
Direct sunlight
Mechanical vibration or shock
Excessive dust
Lack of ventilation, such as cabinet or bookcase
Uneven surface
Install the unit in rooms which exceed 4 m².
Do not install the unit in a place where inflammable gas may leak.
The manufacture may provide other suitable example or may provide additional information
about the refrigerant odour.

9
Check the device after unpacking for any damages or scratches on it.
Operate this unit in an ambient temperature from 41°Fto 95°F.
Do not use in the outdoors. This dehumidifier is intended for indoor residential applications only.
Do not operate in close proximity to walls, curtains, or other objects that may block inlet and outlet.
Keep the air inlet and outlet free of obstacles.
Adjusting the wind deflector in the upward direction prior to start up.
If tipped more than 45°, allow the unit to set upright for at least 24 hours before start up.
Keep doors and windows close for better energy saving.
Do not operate or store the unit in direct sunlight or rain.
It is normal for air outlet to feel warm to touch after continuous operation on hot days.
Empty the water tank before moving the device.
Make sure the Water tank is correctly fitted otherwise the unit will not operate properly.
The dehumidifier starts up in the mode selected when the unit was last used.
The dehumidifier starts dehumidifying if the room humidity is 3% higher than the selected humidity.
There is a protective 3-minutes time delay of the compressor. Wait 3 minutes for the dehumidifier
to resume dehumidification.
4.2 OPERATING THE DEVICE SAFELY

OPERATION
5
10
CONTROL PANEL
SETTINGS
POWER
MODE
In the standby state, press the power button to turn on, the operation indicator lights up and the
default fan speed is high, and the default humidity is 50%. In the power-on state, press the power
button to turn off, the running indicator light goes off and the compressor stops immediately, and
then the fan shut down after 30 seconds delay.
Press the mode button to switch between Auto and Continuously dehumidify mode.
Auto mode - continuously dehumidify mode cycle, press once to switch the mode from one to
another, the corresponding indicator will light up.
Auto mode: when environmental humidity ≥set humidity +3%, the fan starts working and
compressor starts working after 3 seconds. When environmental humidity ≤set humidity -3%,
the compressor stops working and fan stops working after 30 seconds’ delay.
Both fan speed and humidity setting can be adjusted under Auto mode.
●Continuously dehumidify mode: In this mode,The machine will continue to run in high fan speed ,
fan speed is adjustable,humidity setting can not be adjusted.

11
Sleep mode:In sleep mode , the target humidity is 60%, and after no operation for 10 seconds,
except sleeping mode indicator light , power indicator light and child lock indicator light will dark,
other the indicator lights and display screen will be off .
When room humidity ≤57%RH,the compressor & fan will stop working .
When room humidity ≥63%RH,the fan&compressor will start working .
In sleeping mode, when the water tank is full , the machine will not alarm , but the water tank
full indicator light will be on (red color) to remind that the water tank is full and you need to
empty the water tank.
TIMER
FAN
HUM
CHILD-LOCK
Press the timing key to set timing / check timing / cancel timing
A.In the non timing state: press the timing key to enter the timing setting state. The digital screen
flashes to display the timing time. During the flashing period of the digital screen, press the
adjustment key to adjust the timing time (0 ~ 24h).
B.In the timing state: press the timing key, and the digital screen flashes to display the remaining
timing time. Press the timing key again during the flashing period of the digital screen to
cancel the timing.
Press this button to switch the fan speed between high and low fan speed cycle, and the
corresponding indicator light will be on .
The fan speed can be adjusted only in Auto mode.
Press this button to set humidity and timing time;
To humidity adjusting , press one time to add 5% humidity value, the humidity adjusting follow the
order as below : 30% - 35% - 40% - 45% - 50% - 55% - 60% - 65% - 70% - 75% - 80% - 30% cycle.
To timing,press one time to add 1 hours timing value, the timing follow the order as below:
00-01-02-03-04-05-06-07-08-09-10-11-12-13-14-15-16-17-18-19-20-21-22-23-24-00 cycle.
Press and hold this button for 3 seconds to open the child lock function ,the indicator light will
be on and you can not operate other buttons except this one . Press and hold this button for 3
econds again to close the child-lock function ,the indicator light will be off.

12
DRAINAGE
There are two ways of removal collected water produced by the unit.
A. Manual draining: Empty water tank by manual.
B. Continuous draining: Use gravity to drain condensate water by attaching a drain hose.
1.Pull out the water tank 2.Empty the water tank 3.Replace the empty tank back
into the unit
The water tank built in unit will fill up and shut the unit down once it is full. It will run again once
you empty the water tank and installed properly.
1. When the tank is full, The machine will buzz for 5 times, and the “Water Tank Full” indicator light
will light up.
2.Press the POWER button to turn off the unit.
3.Pull on the water tank and simply slide out of the body of the dehumidifier.
4. Empty the water into an area with a drain or outside.
5. Clean the inside of the tank as well as the outside.
6.Replace the empty tank back into the unit.
7.Press the POWER button to resume operating.
8.If the Water Full light does not extinguish, check that the float is correctly in place.
WARNING
1.Do not discard the magnets and plastic rivets in the tank. Otherwise, the dehumidifier cannot
be started, or the machine will not automatically stop working when the water tank is full,
and the condensed water overflow will damage the floor of the room.
A.EMPTYING THE WATER TANK

13
B.CONTINUOUS DRAINAGE
2.Please make sure to clean the condensed water in the tank and put the tank in the
original position.
3.If the water tank is dirty, please rinse it with clean water. Avoid using detergents,
steel wire balls, chemical dust removers, diesel, benzene, diluents or other solvents.
Otherwise, it can damage the tank and cause leaks.
4.Put the water tank in its original position. Otherwise, the indicator light will always be red
and the machine cannot start working again.
1.Take out the PVC pipe, Straighten the drain pipe.
2.Insert one end of the drain pipe into the drain outlet at the top of the tank and connect the
other end to the bathroom, floor drain, outdoor or bucket like container or defined drain area.
1.Please do not block the drainage outlet or drainage pipe, if blocked, condensed water may
overflow and result to water leakage.
2.Please do not bend the drain pipe. The height of the drainage pipe should be lower than
the drainage outlet.
3.The drainage pipe must be firmly connected to the drainage outlet.
Do not submerge the end of drainage pipe into water; otherwise it may cause "Air Lock"in
the pipe ,the water may not flow smoothly and result to water leakage.
WARNING
Drainage pipe

14

MAINTENANCE
6
15
Note: before cleaning and maintaining the machine, please be sure to turn off the machine and
unplug the power to avoid electric shock.
CLEANING THE AIR FILTER (every two weeks)
Dust collects on the filter and restricts the airflow. The restricted airflow reduces the efficiency
of the system and if it becomes blocked it can cause damage to the unit.
The air filter requires regular cleaning. The air filter is removable for easy cleaning.
Do not operate the unit without an air filter, or the evaporator may be contaminated.
1.Switch off the unit and remove air filter
2.Rinse under a running water or using the vacuum to clean the dust
3.Reassemble the air filter

Picture Name Quantity
Dehumidifier 1PCS
Drain Hose 1PCS
User Manual 1PCS
16

TROUBLE SHOOTING
7
17
1.FUNCTIONING TEMP
2.BEFORE CONTACTING FOR SERVICE
41°F Ambient Temp. 95°F
When the ambient temp is lower or higher than the functioning temp, the dehumidifier stops.
When 41°F Ambient temp. 60°F, the compressor automatically defrosts at intervals; during
defrosting, the compressor stops and the fan keeps running.
Before contacting professional service, please review the trouble shooting list that includes
common occurrences that are not the result of a defect in workmanship or materials.
SYMPTOM INSPECTION SOLUTION
The unit is not
operating.
Check the power
connection in securely.
Insert the power cord securely into the
wallOutlet.
Check if the water level
indicator lights up?
Empty the water tank and reinstall
correctly.
Check the room
temperature.
The range of operating temperature is
41- .
95°F
There is little
formation of
condensate.
Check if the air filter the air
filter clogged by dust
Clean the air filter
Check if the air inlet or air
outlet obstructed
Remove the obstruction from the air inlet or
air outlet
Check if the room
temperature is below 68°F.
This is normal. Machine will defrost in low
temperature environment.
Set humidity level is higher
than currentHumidity value.
Set the humidity level below current
humidity value.
Water Leakage
Overflow while moving the
unit. Empty the water tank before transport.
Check if the drain hose is
kinked or bends. Straighten the hose to avoid a trap existing.
Excessive Noise
Check if the unit is securely
positioned.
Place the unit on horizontal and firm
ground.
Check if any loose,
vibrating parts. Secure and tight the parts.
Noise sounds like water
flowing.
Noise comes from flowing refrigerant. This
is normal.
Error
code
E2 Humidity sensor dampened
or failure. To clean or replace the humidity sensor.
CL Display when Room
temperature is below41 °F
Normal. The compressor and fan will stop
working under this condition
CH Display when Room
temperature is above 95°F
Normal. The compressor and fan will stop
working under this condition
LO
Display when Room
relative humidity is bellow
20%RH.
Normal. The compressor and fan will stop
working under this condition
HI
Display when Room
relative humidity is above
90%RH.
Normal. The compressor and the fan will
keep running under this condition
Table of contents