Life BM 66/U User manual

ENGLISH Blood pressure monitor
Instruction manual ................... 2
FRANÇAIS Moniteur de pression artérielle
Mode d’emploi........................ 28
ENGLISH Electromagnetic Compatibility
Information ..................................................56
FRANÇAIS Information sur la compatibilité
électromagnétique .....................................60
BM 66/U
READ THIS MANUAL COMPLETELY AND CAREFULLY
BEFORE USING THIS PRODUCT
Keep this manual in a safe location for future reference
LISEZ CE MODE D’EMPLOI COMPLÈTEMENT ET ATTEN-
TIVEMENT AVANT D’UTILISER CE PRODUIT
Conservez ce manuel en lieu sûr pour y
faire référence ultérieurement
Questions ou commentaires?
Appelez sans frais le 1-800-536-0366
ou écrivez à info@beurer.com
Questions or comments?
Call toll free 1-800-536-0366
or contact info@beurer.com
Manufactured for/Fabriqué pour:
SHOPPERS DRUG MART®
PHARMAPRIXMD
TORONTO, M2J 4W8
®/MD 911979 Alberta Ltd.
Distributed by/Distribué par:
Beurer North America LP
900 N Federal Hwy, Ste 300
Hallandale Beach, FL 33009 USA

2
IMPORTANT SAFETY NOTES
Signs and symbols
The following signs appear in the Safety Section (page 2,3)
and in this manual on pages 7, 8, 10, 11, 12, 16, 17, 18,
22, 23.
READ THIS ENTIRE MANUAL, THE SAFETY SECTION
AND ALL INSTRUCTIONS AND WARNINGS COMPLETE-
LY AND CAREFULLY BEFORE USING THIS PRODUCT.
FOLLOW ALL SAFETY INSTRUCTIONS AND WARNINGS
TO AVOID HAZARDOUS SITUATIONS AND TO MAKE
CORRECT USE OF THIS PRODUCT.
ENGLISH
WARNING WARNING indicates a hazardous situ-
ation which, if not avoided, could re-
sult in death or serious injury.
CAUTION CAUTION indicates a hazardous situa-
tion which, if not avoided, may result
in minor or moderate injury.
NOTICE NOTICE addresses practices not
related to personal injury, such as
product and/or property damage.
Contents
1. Getting to know your instrument.......................................... 3
2. Important information............................................................ 4
3. Package Contents.................................................................. 5
4. Device description.................................................................. 6
5. Getting started........................................................................ 7
5.1 Inserting/Replacing batteries ............................................. 8
5.2 Cuff information ................................................................ 8
5.3 Setting the hour format, date and time.............................. 8
5.4 Operation with AC Adapter ................................................ 9
6. Measuring blood pressure................................................... 10
6.1 Positioning cuff................................................................. 12
6.2 Correct posture ................................................................ 13
6.3 General Notes .................................................................. 14
6.4 Taking measurement........................................................ 15
7. Evaluating results ................................................................. 16
7.1 Irregular heartbeat symbol............................................... 18
7.2 World Health Organization (WHO) classification.............. 18
8. Displaying and deleting measurements............................. 20
9. Care, maintenance and storing the instrument................. 22
10. Error messages/trouble-shooting ...................................... 23
11. Technical Specifications...................................................... 24
12. AC Adapter............................................................................ 26
13. Glossary ................................................................................ 26
14. Warranty and Return Policy................................................. 27

3
WARNING:
•
Please do not share the cuff with other people, to avoid
cross infection.
•
This product is not a toy. Keep it out of reach of chil-
dren, toddlers, and infants.
•
Keep the product out of the reach of pets.
•
Packaging materials are a deadly hazard for children
and can cause suffocation. Remove all packaging ma-
terials immediately and keep them away from children
at all times.
•
This product contains small parts that may present a
choking hazard to children. Keep the unit and all parts
out of reach of children. NEVER LEAVE CHILDREN OR
THOSE WHO REQUIRE CLOSE SUPERVISION UN-
ATTENDED WITH THIS DEVICE.
•
The tubing presents a strangulation hazard. Keep this
product away from children and those who require close
supervision, e.g. people with mental disorders. NEVER
LEAVE CHILDREN OR THOSE WHO REQUIRE CLOSE
SUPERVISION UNATTENDED WITH THIS DEVICE.
SAVE THESE INSTRUCTIONS FOR
FUTURE REFERENCE
If the instruction manual is damaged or if you no longer
have the instruction manual in your possession, please
contact customer service at 1-800-536-0366 or at
info@beurer.com
Dear Customer,
Congratulations on your purchase of this Life Brand Blood
Pressure Monitor.
Please read and understand these instructions completely
and carefully before using this product and keep them for
later reference. Be sure to make them accessible to other
users and observe the information they contain.
1. Getting to know your instrument
The upper arm blood pressure monitor is used for non-inva-
sive measurement and monitoring of adults’ arterial blood
pressure. This allows you to quickly and easily measure
your blood pressure and to display the last recorded meas-
urement. The values determined are classified and graph-
ically evaluated according to World Health Organization’s
(WHO) guidelines.
Blood pressure measurements determined by this mon-
itor are equivalent to those obtained by a trained observer
using the cuff/stethoscope auscultation method, within

4
the limits prescribed by the American National Standard
Institute, Electronic or automated sphygmomanometers.
It is recommended the performance should be checked every
2 years or after repair. Please contact customer service.
2. Important information
Signs and symbols
The following symbols are used in these instructions for
use, on the packaging and on the type plate for the device
and accessories:
Caution
Note
Note on important information
Follow instructions for use
Type BF applied parts
The cuff is type BF applied part
Direct current
Manufacturer
Storage
RH ≤90%
-20°C
55°C
Permissible storage temperature and
humidity
Operating
10°C
40°C
RH ≤90%
Permissible operating temperature and
humidity
Keep dry
SN Serial number
0483
The CE labelling certifies that the product
complies with the essential requirements
of Directive 93/42/EEC on medical prod-
ucts.
Advice on use
•
In order to ensure comparable values, always measure
your blood pressure at the same time of day.
•
Before every measurement, relax for about five minutes.
•
If you want to perform several measurements on the same
person, wait five minutes between each measurement.
•
Do not take a measurement within 30 minutes after eat-
ing, drinking, smoking or exercising.
•
Repeat the measurement if you are unsure of the meas-
ured value.

5
•
The measurements taken by you are for your information
only – they are not a substitute for a medical examination!
Discuss the measurements with your doctor, and never
base any medical decisions on them (e.g. medicines and
their administration)!
•
Do not use the blood pressure monitor on newborns,
pregnant women or patients with preeclampsia.
•
Cardiovascular diseases may lead to incorrect measure-
ments or have a detrimental effect on measurement ac-
curacy. The same also applies to very low blood pres-
sure, diabetes, circulatory disorders and arrhythmias as
well as chills or shaking.
•
The blood pressure monitor must not be used in connec-
tion with a high-frequency surgical unit.
•
Only use the device on people who have the specified
upper arm measurement for the device.
•
Please note that when inflating, the functions of the limb
in question may be impaired.
•
During the blood pressure measurement, blood circula-
tion must not be stopped for an unnecessarily long time.
If the device malfunctions, remove the cuff from the arm.
•
Avoid any mechanical restriction, compression or bend-
ing of the cuff line.
•
Do not allow sustained pressure in the cuff or frequent
measurements. The resulting restriction of the blood flow
may cause injury.
•
Ensure that the cuff is not placed on an arm in which the
arteries or veins are undergoing medical treatment, e.g.
intravascular access or therapy, or an arteriovenous (AV)
shunt.
•
Do not use the cuff on people who have undergone a
mastectomy.
•
Do not place the cuff over wounds as this may cause fur-
ther injury.
•
You can either use the blood pressure monitor with bat-
teries or with an electricity wall outlet. Please note that
data transfer and data storage is only possible when your
blood pressure monitor is supplied with power. As soon
as the batteries are empty or the electricity cable is dis-
connected from the power supply, the blood pressure
monitor loses the date and time.
•
To conserve the batteries, the monitor switches off auto-
matically if no buttons are pressed for one minute.
•
The device is only intended for the purpose described in
these instructions for use. The manufacturer is not liable
for damage resulting from improper or careless use.
3. Package Contents
•
Blood Pressure Monitor Model BM 66/U
•
Arm cuff (arm circumference 22–42 cm / 8.7” to 16.5”)
•
Instruction manual
•
Log Book
•
Storage bag
•
4 x 1.5 V AAA alkaline batteries
•
AC Adapter
Table of contents
Languages: