LIFEBOX bluedot B-BM02 User manual

B-BM02
User manual......................................................2
Automatic Digital
BLOOD PRESSURE MONITOR
EN
คูมือการใชงาน..................................................20
เครื่องวัดความดันโลหิตที่ตนแขนTH

EN : AUTOMATIC DIGITAL BLOOD PRESSURE MONITOR
Thank you for purchasing Automatic Digital Blood Pressure Monitor. It is mainly designed for general
home use. Before using the device, please read this manual carefully to ensure proper and safe
operation. Please take good care of the manual for future reference.
We glad to give you advice and support.
Table of Contents
1. Getting to know your device........................................03
2. Important notes..............................................................03
Signs and symbols.................................................03
Notes on use...........................................................04
Instructions for storage and maintenance.......06
Instructions for repairs and disposal.................06
3. Device description..........................................................07
4. Preparing for the measurement...................................08
Inserting the batteries..........................................08
Operation with the mains adapter.....................09
Display Setup Memory Deletion.........................09
Cuff Connection......................................................09
5. Measuring blood pressure............................................10
Attaching the cuff..................................................10
Adopting the correct posture.............................10
Performing the blood pressure
measurement..........................................................11
Reading Memory....................................................12
Deleting all memory values..................................12
Motion detector......................................................12
Evaluating results..................................................12
6. Abnormal phenomenon and Solutions......................14
7. Maintenace and storage................................................14
8. Technical Specifications................................................15
2

Attention
Note
Note on important information
Observe the instructions for use
Application part, type BF
Direct current
Included in delivery
• Blood pressure monitor B-BM02 1 pc.
• Upper arm cuff size 23-33 cm. 1 pc.
• 1.5 V AA batteries 4 pcs.
• USB wire 1 pc.
• Storage bag 1 pc.
• User manual 1 pc.
1. Getting to know your device
Check that the device packaging has not been tampered
and make sure that all contents are present. Before use,
ensure that there is no visible damage to the device or
accessories and that all packaging material has been
removed. If you have any doubts, do not use the device
and contact your retailer or the specified Customer
Services address.
This new digital blood pressure monitor is an automatic
measuring device to be used on the upper arm. It enable
simple, accurate and fast measurement of blood pressure
and pulse rate by use of the oscillometric method and
people-orientated design.
The advantages of this product:
1. LCD Display
2. Intel comfort
3.Irregular heartbeat detection
4.Motion detection
5. 60 Memories / person ( 2 person )
6.WHO Indicator
7. Use with batteries or USB
2. Important notes
Signs and symbols
The following symbols are used in these instructions for
use, on the packaging and on the type plate for the
device and the accessories:
3

Disposal in accordance with the Waste
Electrical and Electronic Equipment EC
Directive – WEEE
Dispose of packaging in an environmen
-
tally friendly manner
Storage/Transport
Permissible storage and transport tem
-
perature and humidity
Operating
Permissible operating temperature and
humidity
Protect from moisture
The CE labeling certifies that the product
complies with the essential requirements
of Directive 93/42/EEC on medical pro
-
ducts.
Notes on use
• In order to ensure comparable values, always measure
your blood pressure at the same time of day.
• Before every measurement, relax for about five minutes.
• If you want to perform several measurements on the
same person, wait five minutes between each measure
ment.
• Do not take a measurement within 30 minutes of eating,
drinking, smoking or exercising.
• Repeat the measurement if you are unsure of the
measured value.
• The measured values taken by you are for your
information only – they are no substitute for a medical
examination. Discuss the measured values with your
doctor and never base any medical decisions on them
(e.g. medicines and their administration).
• Using the blood pressure monitor outside your home
environment or whilst on the move (e.g. whilst travelling
in a car, ambulance or helicopter, or whilst undertaking
physical activities such as playing sport) can influence
the measurement accuracy and cause incorrect
measurments.
• Do not use the blood pressure monitor on newborns or
patients with pre-eclampsia. We recommend consulting
a doctor before using the blood pressure monitor during
pregnancy.
4

• Cardiovascular diseases may lead to incorrect
measurements or have a detrimental effect on
measurement accuracy. The same also applies to very
low blood pressure, diabetes, circulatory disorders and
arrhythmias as well as chills or shaking.
• This device is not intended for use by people (including
children) with restricted physical, sensory or mental
skills or a lack of experience and/or a lack of knowledge,
unless they are supervised by a person who is
responsible for their safety or are instructed by such a
person in how to use the device. Supervise children
around the device to ensure they do not play with it.
• The blood pressure monitor must not be used in
connection with a high-frequency surgical unit.
• Only use the device on people who have the specified
upper arm measurement for the device.
• Please note that when inflating, the functions of the
limb in question may be impaired.
• During the blood pressure measurement, the blood
circulation must not be stopped for an unnecessarily
long time. If the device malfunctions remove the cuff
from the arm.
• Do not allow sustained pressure in the cuff or frequent
measurements. The resulting restriction of the blood
flow may cause injury.
• Make sure that the cuff is not placed on an arm in which
the arteries or veins are undergoing medical treatment,
e.g. intravascular access or intravascular or therapy, or
an arteriovenous (AV) shunt.
• Do not use the cuff on people who have undergone a
mastectomy.
• Do not place the cuff over wounds as this may cause
further injury.
• Place the cuff on your upper arm only. Do not place the
cuff on other parts of the body.
• The device is only intended for the purpose described in
these instructions for use. The manufacturer is not
liable for damage resulting from improper or careless
use.
5

Instructions for storage and maintenance
• The blood pressure monitor is made from precision and
electronic components. The accuracy of the measured
values and service life of the device depend on its
careful handling:
– Protect the device from impacts, humidity, dirt,
marked temperature fluctuations and direct sunlight.
– Do not drop the device.
– Do not use the device in the vicinity of strong
electromagnetic fields and keep it away from radio
systems or mobile telephones.
– Only use the cuff included with the delivery or original
replacement parts. Otherwise incorrect measured values
will be recorded.
• We recommend that the batteries be removed if the
device will not be used for a prolonged period of time.
Notes on handling batteries
• If your skin or eyes come into contact with battery fluid,
rinse the affected areas with water and seek medical
assistance.
Choking hazard! Small children may swallow and
choke on batteries. Store the batteries out of the reach
of small children.
• Observe the plus (+) and minus (-) polarity signs.
• If a battery has leaked, put on protective gloves and
clean the battery compartment with a dry cloth.
• Protect batteries from excessive heat.
Risk of explosion! Never throw batteries into a fire.
• Do not charge or short-circuit batteries.
• Use identical or equivalent battery types only.
• Always replace all batteries at the same time.
• Do not use rechargeable batteries.
• Do not disassemble, split or crush the batteries.
Instructions for repairs and disposal
• Batteries do not belong in household waste. Please
dispose of empty batteries at the collection points
intended for this purpose.
• Do not open the device.
Failure to comply will result in voiding of the warranty.
• Do not repair or adjust the device yourself. Proper
operation can no longer be guaranteed in this case.
• Repairs must only be carried out by Customer Services
or authorised suppliers. Before making a claim, please
check the batteries first and replace them if necessary.
6

• Please dispose of the device in accordance with EC
Directive – WEEE (Waste Electrical and Electronic
Equipment). If you have any questions, please
contact the local authorities responsible for
waste disposal.
Notes on electromagnetic compatibility
• The device is suitable for use in all environments listed
in these instructions for use, including domestic
environments.
• The use of the device may be limited in the presence of
electromagnetic disturbances. This could result in issues
such as error messages or the failure of the display/
device.
• Avoid using this device directly next to other devices or
stacked on top of other devices, as this could lead to
faulty operation. If, however, it is necessary to use the
device in the manner stated, this device as well as the
other devices must be monitored to ensure they are
working properly.
• The use of accessories other than those specified or
provided by the manufacturer of this device can lead to
an increase in electromagnetic emissions or a decrease
in the device’s electromagnetic immunity; this can result
in faulty operation.
• Failure to comply with the above can impair the
performance of the device.
3. Device description
1. Cuff
2. Cuff line
3. Cuff connector
4. Display
5. Connection for cuff connector
6. Risk indicator (WHO standard)
7. Intel comfort Symbol
8. Memory button
9. START/STOP button
10. Setting button
11. USB port
7
5
7
8 9 10
11
1 2 3
6
4

Information on the display:
1. Systolic pressure (SYS) (mmHg)
2. Diastolic pressure (DIA) (mmHg)
3. Calculated pulse value
4. Time and date
5. Cardiac arrhythmia symbol
6. User memory
7. Motion detector
8. Battery replacement symbol
9. Pulse symbol
10. Risk indicator (WHO standard)
4. Preparing the measurement
Inserting the batteries
Press the indicator on the battery cover and
slide the cover off in the direction of the arrow
Insert 4 “AA” size batteries, align the polarities of
the battery.
Note: If the low battery indicator appears
on the display, the batteries must be replaced.
This monitor can also be operated with USB
charging
WARNING Please purchase USB charging and
Power adapter with CE certification. Do not plug
or unplug the power cord into the electrical
outlet with wet hands.
8
1
2
3
4
7
6 5
8
9
10

Display Setup Memory Deletion
It is essential to set the date and time.
Otherwise, you will not be able to save your measured
values correctly with a date and time and access them
again later.
• Before initial use and after each time you replace the
battery: When inserting batteries into the device, you will
be taken to the relevant menu automatically.
• If the batteries have already been inserted:
Press and hold the settings button SET on the device
when switched off for approx. 3 seconds.
Enter into the setup interface, the content of setup will be
displayed by flashing. Press the SET button , it will
enter into the switch of setup content:
“memory deletion -> year -> month -> day -> hour ->
minute.”
• Press memory button to revise setup value.
• Press ON/OFF button to store the setup content.
Note: This monitor displays one unit mmHg.
Cuff Connection
Insert the air tube plug into the socket by revolving it.
If the low battery indicator is permanently displayed,
you can no longer perform any measurements and must
replace the batteries. Once the batteries have been
removed from the device, the time must be set again.
Battery disposal
• The empty, completely flat batteries must be disposed
of through specially designated collection boxes,
recycling points or electronics retailers. You are legally
required to dispose of the batteries.
Operation with the USB
You can also operate this device with a USB charging.
When doing so, there must not be any batteries in the
battery compartment.
• To prevent possible damage to the device, the blood
pressure monitor must only be used with the USB
charging described here.
• Insert the USB wire into the connection provided for this
purpose on the blood pressure monitor. Power adapter
must only be connected to the mains voltage that is
specified on the type plate.
• Then insert the mains plug of the Power adapter into the
mains socket.
• After using the blood pressure monitor, unplug the
Power adapter from the mains socket first and then
disconnect it from the blood pressure monitor.
9

Blood pressure may vary between the right and left arm,
which may mean that the measured blood pressure
values are different. Always perform the measurement on
the same arm. If the values between the two arms are
significantly different, please consult your doctor to
determine which arm should be used for the measure-
ment.
Important: The unit may only be operated with
the original cuff. The cuff is suitable for an arm
circumference of 23 to 33 cm.
Adopting the correct posture
5. Measuring blood pressure
Ensure the device is at room temperature before
measuring. The measurement can be performed on the
left or right arm.
Attaching the cuff
Place the cuff onto the bare
upper arm. The circulation of
the arm must not be hindered
by tight clothing or similar.
The cuff must be placed on the
upper arm so that the bottom
edge is positioned 1 – 2 cm.
above the elbow and over the
artery. The line should point
to the centre of the palm.
Now tighten the free end of the
cuff, but make sure that it is
not too tight around the arm
and close the hook-and-loop
fastener. The cuff should be
fastened so that two fingers can
fit under the cuff.
The arm cuff should be at the
same level as your heart.
Sit upright with
your back straight.
Take off thick clothes, wear
thin clothes or bare your
upper arm for measurement
10

• Before the initial blood pressure measurement, make
sure always to rest for about 5 minutes. Otherwise
deviations can occur.
• Furthermore, if you want to take several measurements
in succession, make sure always to wait for at least 3-5
minute between the individual measurements.
• You can take the measurement while sitting or lying.
Always make sure that the cuff is at heart level.
• To carry out a blood pressure measurement, make sure
you are sitting comfortably with your arms and back
leaning on something. Do not cross your legs. Place your
feet flat on the ground.
• To avoid falsifying the measurement, it is important to
remain still during the measurement and not to speak.
Performing the blood pressure measurement
1. Press SET button to choose user A or user B.
2. Attaching the cuff
3. Press ON/OFF button to power on, The pump starts
to inflate the cuff.
4. After having reached the anticipated value of inflation,
the monitor starts to deflate automatically with a
constant speed to detect your blood pressure and pulse.
5. When the measurement is completed,
your blood pressure and pulse rate
will be displayed.
Example:
SYS : 128 mmHg
DIA : 78 mmHg
Pulse : 72 bmp
The result will be stored automatically.
The storage series number is “0”, doesn’t have memory.
The previous measurement serial number is “1,2,3,...,60”
6. To shut off the monitor, press ON/OFF buttom.
Note: Once you feel uncomfortable with inflation
or the inflation becomes ceaseless, please loosen the cuff
and pull out the air tube immediately.
Don’t talk, move your arm or body during the measure-
ment.
11

The monitor will be automatically shut off in 2 minutes
without operation. When the monitor can’t measure the
value correctly, the screen will display “E” icon.
Press ON/OFF button to shut off the monitor and wait for
4 to 5 minutes to start a new measurement.
At the same time, follow the following suggestions during
the measurement to avoid “E” icon display again.
1. Keep quiet and correct posture.
2. Fit the cuff correctly.
3. Connect the air tube correctly.
4. Avoid the electromagnetic interference.
Reading Memory
Press memory button to read memory.
Press memory button or SET button to cycle switch.
Note: The monitor can memorize 60 data. The
monitor will delete the earliest data automatically when
the number of data is beyond 60.
Deleting all memory values
Press SET button for about 3 seconds to enter the
setting mode. All memory values show flashing status.
Press Memory to select Delete. “0” will delete all
memory values and press the On/Off button to
confirm.
Motion detector
The icon will show on display when device detect
movement during measurement.
Evaluating results
Cardiac arrhythmia:
This device can identify potential disruptions of the heart
rhythm when measuring and if necessary, indicates this
after the measurement with the symbol . This can be
an indicator for arrhythmia. Arrhythmia is an illness in
which the heart rhythm is abnormal because of flaws in
the bioelectrical system that regulates the heartbeat. The
symptoms (skipped or premature heart beats, pulse being
slow or too fast) can be caused by factors such as heart
disease, age, physical make-up, excess stimulants, stress
or lack of sleep. Arrhythmia can only be determined
through an examination by your doctor. If the symbol
is shown on the display after the measurement has been
taken, repeat the measurement. Please ensure that you
rest for 3-5 minutes beforehand and do not speak or
move during the measurement. If the symbol appears
frequently, please consult your doctor. Self diagnosis and
treatment based on the measurements can be dangerous.
Always follow your GP’s instructions.
12

Risk indicator:
The measurements can be classified and evaluated in
accordance with the following table. However, these
standard values serve only as a general guideline, as the
individual blood pressure varies in different people and
different age groups etc. It is important to consult your
doctor regularly for advice. Your doctor will tell you your
individual values for normal blood pressure as well as the
value above which your blood pressure is classified as
dangerous.
Table for Classifying Blood Pressure Values (mmHg): WHO
Life Guide for Hypertension Patients
• High blood pressure (Hypertension);
A blood pressure of 140/90 or higher is considered high
blood pressure. High blood pressure (HBP) is a serious
condition that can lead to coronary heart disease, heart
failure, stroke, kidney failure, and other health problems.
Blood pressure tends to rise with age. Following a healthy
lifestyle helps some people delay or prevent this rise in
blood pressure.
The following measures can be regarded as a life guide
for hypertension patients:
1) Consult your doctor about your blood pressure in daily
life.
2) Maintain a normal weight.
3) Avoid excessive consumption of common salt. Avoid
high cholesterol foods and fatty foods. Eat more fruits,
vegetables and high-fiber foods.
4) Avoid smoking, alcohol and reviver.
5) Moderated exercise.
6) Relax and reduce stress. Stress can increase the blood
pressure suddenly. Relax and reduce stress is a good
habit for your health.
Optimal
High-normal
Normal
SYS
mmHg
DIA
mmHg
<120
Action
< 80 self-monitoring
80-84
120-129
85-89
130-139
90-99140-159 regular monitor-
ing by doctor
regular monitor-
ing by doctor
self-monitoring
100-109
160-179
≥110
≥180 seek medical
attention
seek medical
attention
Severe
Hypertension
Moderate
Hypertension
Mild
Hypertension
Blood Pressure
Classification
13

Troubleshooting
14
Abnormal
Phenomenon Potential cause Solutions
Power on
doesn’t work
Low battery or wrong
polarities of batteries aligned
Replace old batteries with new
ones; Align the polarities of the
battery correctly.
Cuff leakage Replace old cuff with new one
No inflation
Air tube plug is not correctly
connected
Check the connection of the
air tube and connect properly
if necessary.
Abnormal value
Cuff is not fitted on the arm
correctly
Talk during the measurement Keep quiet during measurement
Fit the cuff correctly see page 10.
Roll-up sleeve pressed
on the arm
Nervous or excited Keep quiet, take a deep breath
Take off the clothes on the arm,
restart measuring
to calm down
Symbol Cause Solutions
E
Air tube plug is not
correctly connected
Keep your body still, never move
the monitor. Restart measuring
Manually inflate to meet the
requirement. Restart measuring
The inflation is 30 mmHg lower
than expected systolic value
Failure inflation
Failure measurement
Fit the cuff correctly
Check the connection of the air
tube and connect it properly
if necessary. Restart measuring.
Check the connection of the air
tube, keep quiet and restart
measuring
E1
The monitor or arm is moved
during the measurement
The device will deflate automaticly
E4
E5
The inflation is above 300
mmHg
6. Abnormal phenomenon and Solutions
Error Indicators

7. Maintenance and storage
1. Do not subject the monitor and package to shocks,
such us dropping it onto the floor.
2. Do not submerge the device or any of the components
in water. Do not subject the monitor to extreme
temperatures, dust, humidity, corrosive gas and drect
sunlight, do not use it in an oxygen rich environment.
3. Use the cuff carefully. The cuff contains a sensitive
gasbag and should not be forcely bended.
4. Clean the monitor with soft and dry cloth. Don’t use
gasoline, thinners or similar solvents.
5. Carefully remove spots on the cuff with a damp cloth
and soapsuds. It should not be washed with detergent
powder and other detergents.
6. Use only approved parts and accessories. Not
approved parts and accessories may damage the unit.
7. Store the device and the components in a clean, safe
location.
8. About batteries: If the monitor is not to be used for a
long time, remove the batteries to prevent battery
leakage.
15
8. Technical Specifications
Model No. B-BM02
System Fully Automatic inflation and
deflation
Measuring Range Cuff Pressure: 0-290 mmHg
Pulse: 40~180 bpm
Accuracy Pressure: ± 3 mmHg
Pulse: ± 5% of the reading
Display LCD digital display
65 x 90 mm.
Memory 2 x 60 memory spaces
Dimension 110 x 150 x 74 mm.
Weight 330 g (without batteries)
Cuff size 23-33 cm
Operating Condition Temperature: 5°C~40°C
Humidity: 15% RH~85% RH
Air Pressure: 860 hPa~1060 hPa
Storage Condition Temperature: -20°C~70°C
Humidity: 10% RH~95% RH
Air Pressure: 860 hPa~1060 hPa
Power source 4 x 1.5V “AA” batteries or
AC adapter DC6V

16
Guidance and Manufacturer’s Declaration
Important information regarding Electro Magnetic
Compatibility (EMC)
This product needs special precautions regarding EMC
and needs to be installed and put into service according
to the EMC information provided, and this unit can be
affected by portable and mobile RF communications
equipment.
a)* Do not use a mobile phone or other devices that emit
electromagnetic fields, near the unit. This may result in
incorrect operation of the unit.
b) Caution: This unit has been thoroughly tested and
inspected to assure proper performance and operation!
c)* Caution: this machine should not be used adjacent to
or stacked with other equipment and that if adjacent or
stacked use is necessary, this machine should be
observed to verify normal operation in the configuration
in which it will be used.

17

18

19

TH : เครื่องวัดความดันโลหิตที่ตนแขน
ขอขอบคุณที่เลือกใชผลิตภัณฑเครื่องวัดความดันโลหิตแบบอัตโนมัติของเรา ตัวเครื่องถูกออกแบบมา สําหรับใชงาน
ภายในบาน กอนใชอุปกรณโปรดอานคูมือนี้อยางละเอียดเพื่อใหแนใจวาใชงานถูกตอง และปลอดภัย โปรดเก็บคูมือการ
ใชงานนี้เพื่อเปนขอมูลสําหรับผูใชงานอื่นๆ และการศึกษาเพิ่มเติมในครั้งตอไป เรายินดีใหคําแนะนํา
และสนับสนุนการใชงานของคุณ
สารบัญ
1. ทําความรูจักกับอุปกรณ....................................................21
2. คําอธิบายความปลอดภัย..................................................21
เครื่องหมายและสัญลักษณ.......................................21
คําแนะนําการใชงาน...................................................22
คําแนะนําในการเก็บและดูแลรักษา..............................23
คําแนะนําในการซอมแซมและกําจัด............................24
3. คําอธิบายอุปกรณ.............................................................25
รายละเอียดสัญลักษณที่แสดงบนหนาจอ.................25
4. การเตรียมอุปกรณ.............................................................26
การใสแบตเตอรี่.........................................................26
การใชงานผานอแดปเตอร.........................................26
การตั้งคาการลบหนวยความจํา...............................27
การเชื่อมตอผาพันตนแขนกับเครื่อง........................27
5. การวัดความดันโลหิต.........................................................27
การสวมผาพันตนแขน..............................................27
การใชทาทางที่ถูกตอง..............................................28
การเริ่มทํางานของเครื่องวัดความดันโลหิต.............28
การอานคาหนวยความจํา.........................................29
การลบคาหนวยความจํา.........................................29
เครื่องสามารถตรวจจับความเคลื่อนไหวได..............29
การประเมินผลลัพธ...................................................30
6. ขอความแสดงความผิดพลาดและวิธีแกไข.........................31
7. การบํารุงรักษาและการเก็บรักษา.......................................31
8. ขอมูลทางเทคนิค...............................................................32
20
Table of contents
Languages:
Other LIFEBOX Blood Pressure Monitor manuals