INSTALLATION & SAFETY INSTRUCTIONS
MODEL: FSTM7
These instructions are for guidance only
Read these instructions fully before using the fitting.
Retain these instructions for future reference.
PLEASE CONSULT A QUALIFIED ELECTRICIAN
General safety instructions
• Ensure mains power is disconnected & switched o when installing the fitting
• To clean: Ensure that the fitting is disconnected from the mains and cannot be unintentionally reconnected.
• Place only upon level and stable surfaces.
• Do not use in areas in which there is a danger of explosion.
• Do not use near flammable materials.
• Do not place in water or other liquids.
• Never operate with wet hands.
• Never cover the equipment.
• Never operate when the casing is open, or when the wiring casing is missing or damaged, or when the casing is defective.
• Never attempt to repair this unit yourself. Repairs should only be carried out by a qualified electrician
• If the supply cord is damaged, stop using the unit immediately & consult a qualified electrician
• If casing is broken, stop using the unit immediately & consult a qualified electrician
Programming the timer to continue through midnight
1. Program the ON time as described above.
2. Program the OFF time as 23:59.
3. Program the first program for the next day to come on at 00:00.
Modifying or Adding Programs
1. Press PROG and hold for 3 seconds.
2. The mode in which it was last programmed will be displayed. (7 Day or 5 Day for instance).
3. The mode can be adjust using the BOOST/ADV buttons from 5 Day to 7 Day or another mode.
4. Press PROG to accept the new mode and advance to adjusting the timer ON/OFF settings.
5. Review the times and adjust as described in ‘Timer Programming’ section.
BOOST Button
1. Press the BOOST button once to switch the load on for 1 hour. BOOST 1displays on the screen.
2. Press the BOOST button twice to switch the load on for 2 hours. BOOST 2displays on the screen.
3. Press the BOOST button three times to turn the load o again.
ADVANCE Button
1. Press the ADV button once to switch the load on continuously until the next Timer OFF setting is reached.
2. Press the ADV button twice to override the timer. The load will stay on permanently until the ADV button is pressed
again, returning the device to timer mode.
Operating voltage 220-240V AC
Operating frequency 50Hz
Load/switch rating
13A (3kW) Max (Resistive), 700W Incandescent/halogen
lighting, 500W Fluorescent lighting, 80W CFL Lighting, 150W
LED
Operating Temperature 0 to 40’C
Battery back-up Up to 4 weeks
Timer type 7 day, 24 hour digital
Contacts Normally Open, not volt-free
Terminals max cable size 2 x 2.5mm or 1 x 4mm
Dimensions 85mm (w) x 85mm (h) x 38mm (d)
Specifications
Correct Disposal of this product
This marking indicates that this product should not be disposed with other household wastes throughout the EU. To prevent possible harm to the
environment or human health from uncontrolled waste disposal, recycle it responsibly to promote the sustainable reuse of material resources. To return
your used device, please use the return and collection systems or contact the retailer where the product was purchased. They can take this product
for environmental safe recycling.
Guarantee
This product is manufactured from high quality components and is quality assured to meet the standards set by the European
Commision and BSI.
This product is covered by a 3 year manufacturer’s guarantee.
In the unlikely event that you experience a fault with the product, please return it to your supplier with proof of purchase for a
replacement.
Faults arising from the use of this product for any reason outside the scope of these instructions and the product’s intended
use, will result in the guarantee being rerndered void.
This product is only suitable for use within the parameters stated in this instruction manual. Any deviation in usage by the customer, installation errors,
overloading of the device or any other misuse will not be covered under the manufacturer’s guarantee. It is the sole responsibility of the installer of the
product to ensure that it is suitable for the application and used and installed within the parameters advised by the manufacturer.

Setup Instructions
Before programming the device, it is recommended that you press the RESET button
using a pointed object such as a paper clip or pencil. The screen will display CODE.
Setting Date and Time
1. Hold the TIME button until the year setting appears flashing.
2. Select the year by using the BOOST/ADV buttons.
3. Press the TIME button to move on to the month setting.
4. Set the correct month using the BOOST/ADV buttons.
5. Press the TIME button to move on to the day of the month setting.
6. Set the correct date using the BOOST/ADV buttons.
7. Press the TIME button to move on to the time setting.
8. Set the correct hour using the BOOST/ADV buttons.
9. Press the TIME button to move on to the minute setting.
10. Set the correct minutes using the BOOST/ADV buttons.
11. Press the TIME button and the time/date settings are complete.
Timer Programming
1. Hold the PROG button for 3 seconds. The 7 Day Program mode will display.
2. Press the ADV button to scroll through the program modes, as follows:
3. Once selected, press the PROG button to advance to setting the ON time for program 1.
4. Adjust the hour using the BOOST/ADV buttons, then press the PROG button and do the same again
to set the minutes.
5. Press the PROG button again to advance to setting the OFF time for program 1.
6. Repeat processes 4&5 to set the OFF timings.
7. Press PROG to advance to program 2 and repeat the process again.
8. There are 4 programs available per day that can be set or left blank if not required.
9. Press PROG to exit programming mode. The PROG button can be pressed and held for 3 seconds
at any point during programming to return to operating mode.
10. NOTE: The main switch needs to be set to the down position with the red line showing on top (ON)
for the programmer to work and switch the load.
• Mo Tu We Th Fr Sa Su - 7 Day mode - Enables setting the same timer ON/OFF settings for
each week day.
• Mo Tu We Th Fr - 5 Day mode - Enables setting the same timer ON/OFF settings for each
week day.
• Sa Su - Weekend mode - Enables setting the timer ON/OFF settings for weekend days only.
• Mo - Individual day mode - Enables setting dierent timer ON/OFF settings for each day of
the week.
Pack Contents
• Instruction leaflet
• 7 Day programme time switch
• Cable clamp set
• 2 x 3.5mm x 35mm socket box screws
Display screen
Programme Set
Time and
date set
Reset Button
Power Indicator
Output Indicator
Boost button will
override current
programme in hour
increments as selected.
2 hours max.
Advance button
will move to
the next set
programme
Features / Specifications
Switched fused spur with programmable timer with display, 1 or 2 hour boost function & override
facility.
•Program settings: 7 Day, 5 Day (Week days only), 2 Day (Weekend only)
•Up to 4 x ON/OFF switch timings per day.
•Battery back-up in case of mains power failure
•LED indicators for Mains Power ON & Output Power ON
•1 or 2 hour ‘Boost’ function
•‘Advance’ override boost - switches o at next programed timer event
•Front cable outlet for connection of load with cable clamp
•Double pole switch
•Fits 25mm back box
•Replaceable BS1362 fuse at front
•220-240V A.C
Double pole switch BS 1362 (1” x 1/4”) fuse
Installation
•This unit should only be installed by a qualified electrician, adhering to the local regulations and
guidance covering the installation.
•The spur is designed to fit a 1 gang 25mm deep (min) back box.
•The unit can be used as part of a ring main and can accept 2 x 2.5mm T&E conductors per terminal.
•An earth loop through connector is supplied if required.
•If the unit is installed in a metal back box, earthing of the back box is necessary.
•Switch o the mains power supply at the fuse board before connecting the unit.
•Connect the supply to L IN & N IN. Connect the load to L OUT & N OUT.
•The load cable can be fed through the front cable exit and should be clamped using the supplied
cable clamp.
Suitable for use with:
•Resistive loads (3kW max) - such as Immersion Heaters
•Incandescent / Halogen Lighting (700W max)
•Fluorescent Lighting (500W max)
•CFL Compact Fluorescent Lighting (80W max)
•LED Lighting (150W max)
•Not suitable for use with discharge lighting
Note:
The time is a 24hr clock.
Holding down the ‘BOOST’ or
‘ADV’ button will advance or
decrease the settings more
Important Information
This timer is only suitable for installation in systems where it is constantly powered. It may not be suitable
for installation into a system where the mains supply is regularly lost or switched o such as Economy 7
or 10 systems. It can be used on Economy 7 or 10 systems where the power is not switched o at any
point, but just switched between taris.
Regular loss of power to the timer may result in the battery becoming over-discharged and errors may
occur in the programming and with the reliability of the internal clock.
The battery within this product is designed to retain the clock timing and program setting during the
event of an occasional power cut.
Popular Lighting Equipment manuals by other brands

Elation
Elation ELED STRIP 100 User instructions

Sentiotec
Sentiotec LED-FLS Instructions for installation and use

Starway
Starway DAYTONA user manual

Larson Electronics
Larson Electronics EPL-150LED-RT-SP0010-200C Series instruction manual

Ikan
Ikan Rayden RB5 quick start guide

p-light
p-light Hydro 880 Installation and instructions for use