LightLife DMX2DIM User manual

User Manual
DMX2DIM
©LightLife Gesellschaft für audiovisuelle Erlebnisse mbH
DMX 512/1990 controllable 6 channel
trailing-edge dimmer for
ohmic and capacative loads
(6 x 300 VA) Art.-No.: 10001099

Technical Specications
Important note!
Power
Number of channels
Frequency
Current Consumption
Maximum switching losses
Shut-down speed
Total power dissipation
Efciency
Connection terminal
Fan
Protection class
Overvoltage category
IP protection class
Ambient temperature
Connection type
Fuse
Dimensions L x W x H
Weight
230 VAC
6 x 300 VA / 230 VAC (3 x 600 VA)
40 Hz - 70 Hz (usual 50 Hz/60 Hz)
approx. 150 mA without load (apparent current 230 VAC without
load), Power consumption without load approx. 4 W,
Inductive power consumption without load approx. 35 VA
6 x 12 mW (66 mW)
approx. 34 µs
28 W (6 x 300W load, 230 VAC)
98,5 % (at full load)
Cross section of 0.5 mm² bis 2.5 mm²
Noise @ 1m 19 dB (A)
1
2
IP20
max. 40 degree celsius at full load
Y
externally via line circuit breaker 10 A - 16 A
(Characteristic B, maximum of 5 Dimmer per line circuit breaker)
212 x 105 x 68 mm
0,8 kg
The main electrical input of the dimmer has NO Fuse. It is only required to operate the dimmer
with an external fuse. In addition, a circuit breaker with a maximum of 16 A must be provided
(Characteristic B).
LightLife Gesellschaft für audiovisuelle Erlebnisse mbH
Robert-Perthel-Straße 47,50739 Köln
Tel. +49 (0) 221 – 977 654 0,Fax +49 (0) 221 – 977 654 29
www.lightlife.de

Thanks!
Modifying of the QR Code
Content
2
3
4
6
7
8
10
12
13
14
15
Technical Specications/Important notes regarding commissioning
Table of contents
Device Overview
Shipment/General device description
Operating instructions/Installation
DIP-Switch Settings
DMX Addressing
Selection of dimmer curves
Miscellaneous and troubleshooting
Installation of the load circuit
Channel bundle
Thank you for purchasing our DMX2DIM dimmer. We appreciate your trust at this early stage
and wish you a successful installation.
Ex-works each DMX2DIM dimmer is labeled with a QR Code. This QR Code directs you
directly to the online user manual. We strongly recommend to exchange the standard Code
with your own QR Code. Thus, in the event of fault you have direct access to the system for
troubleshooting - even on the weekends.
3

DMX IN/DMX OUT
(Connector Block)
Control circuits (terminal) Channel 1-6
Jumper for the DMX
Terminator (120 Ohm)
E
B
A

DMX IN/DMX
OUT (RJ45) DMX Start-Address
data switch
Code switch (basic functions)Power supply
Device Overview
GF
DC
5

The LightLife DMX2DIM is a 6 Channel Dimmer for Din Rail mounting.
The dimensions of the dimmer t to 12 TE DB. To ensure enough cooling, you might adjust the
cover of the housing.
The mounting depth has to be at least 48 mm (distance from Din Rail to Cover). The DMX
interface handles USITT DMX 512/1990 with 3 or 6 channels. You cannot use the dimmer for
inductive loads (for example conventional ballast).
The maximal ohmic or capacative work load for the trailing-edge dimmer is max. 1800
VA / 230 VAC. To adjust output for consumer load, two output channel can be operated
simultaneously to control each 600 VA over three DMX channels. MOSFETs are being used
as switching elements. You can use up to ve dimmers (DMX2DIM) on a 16 A circuit breaker
(Characteristic B). The ESD protected in-and outputs are electrically isolated from the CPU
control. In addition to the manual addressing, the dimmer can also be operated in automatic-
addressing mode.
If the DMX2DIM is at the end of the DMX data line, it is possible to terminate the line via the
internal 120 Ohm Jumper (A). The DMX IN-/OUTPUT is usable as a RJ45 plug (building layout
according to e:cue Standard, www.ecue.de) or as terminal connection with spring terminals.
1 pcs DMX2DIM
1 pcs User Manual
Shipment
General Discription

The DMX2DIM is an electrical device and is not prepared for use in an explosive or humid
environment. LightLife Gesellschaft für audiovisuelle Erlebnisse mbH is not liable for damages
or malfunctions due to improper use. The product DMX2DIM may not modi ed or changed.
Operating Instructions
Before installing your dimmer, be beware of the general electrical standard, rules and
regulations in your country. You will nd tips and hints in the user manual.
The installation and commissioning is only allowed by authorized personal. The dimmer is
actively cooled via fan and needs suf cient clearance to enclosure. The minimal distance to
other devices and ambient temperature are required to be in the indicated tolerances.
The dimmer has Block clamps until 2.5 mm². At a size 2.5 mm² the cable end sleeve has to
have a length of 15 mm. To unlock the cable from the block clamps, please don´t use force or
gripper. Please use a smal screw driver and push the spring clamp gentle to release the wires
from the block. On the ground plate you will nd a holding system to mount the dimmer on a
35 mm Din Rail. The housing of the dimmer must be grounded separately. To lock the Dimmer
on the Din Rail hold the ground plate with the spring mechanism to the lower end of the rail
and push the dimmer gently upwards to the top of the rail. The dimmer will immediately snap
in into the rail. You can still adjust the dimmer vertical on the din rail. The dimmer housing is
internally wired to the ground connector.
In the case of long cabling or electrical interferences you have to set the DMX Terminator with
the Jumper A.
Installation
A
7

ON
OFF
Each dimmer channel (non-dim) is switched off until DMX Level 127. On the DMX
Level 128 the dimmer will interconnect. The dimmer will be used as NON dim. The
dimmer will switch like a standard I/O Switch.
On channel bundle 3 x 600 W all dip switches are connected. At this case you have
to put at least one dip switch on Position ON.
Normal dimmer function on each channel according to the dimmer curve.
DIP-Switch 1-6
DIP-Switch Settings
ON
OFF
Channel bundle activated: Channel 1,2 / Channel 3,4 / Channel 5,6 will be
connected each to one channel. Thereby, the max. work load will increase to 600 W
per bundle dimmer. The channels have to connected simultaneously at the output.
Now, 3 DMX addresses are in use.
Channel bundle is off. The dimmer is operating in the 6 channel mode with a
maximal work load of 300 W per output. Now, 6 DMX addresses are in use.
DIP-Switch 7
ON
OFF Dimmer curve 2
Dimmer curve 1
DIP-Switch 8
1 2 3 4 5 6 7 8 9 10
ON Channel 1
interconnect at
DMX Level 128
Channel 2
interconnect at
DMX Level 128
Channel 3
interconnect at
DMX Level 128
Channel 4
interconnect at
DMX Level 128
Channel 5
interconnect at
DMX Level 128
Channel 6
interconnect at
DMX Level 128
3 Channel modus
at 600 W
max. workload
dimmer curve
2Auto Frequence 60 Hz
OFF Channel 1 dims
between DMX-
Level 0-255
Channel 2 dims
between DMX-
Level 0-255
Channel 3 dims
between DMX-
Level 0-255
Channel 4 dims
between DMX-
Level 0-255
Channel 5 dims
between DMX-
Level 0-255
Channel 6 dims
between DMX-
Level 0-255
6 Channel modus
at 300 W
max. workload
dimmer curve
1Fixed frequency 50 Hz
G

ON
OFF
Auto Frequency.The dimmer automatically interpolates the frequency. Additionally,
the duration of 50 half-waves is measured and averaged. To ensure a trouble free
operation the frequency has to be between 45 - 65 Hz. Line failures during measuring
could perhaps falsify the result.
The dimmer is set to a xed frequency of 50 Hz or 60 Hz (Dip switch 10).
DIP-Switch 9
ON
OFF
Fixed Frequency: 60 Hz
Fixed Frequency: 50 Hz
DIP-Switch 10
1 2 3 4 5 6 7 8 9 10
ON Channel 1
interconnect at
DMX Level 128
Channel 2
interconnect at
DMX Level 128
Channel 3
interconnect at
DMX Level 128
Channel 4
interconnect at
DMX Level 128
Channel 5
interconnect at
DMX Level 128
Channel 6
interconnect at
DMX Level 128
3 Channel modus
at 600 W
max. workload
dimmer curve
2Auto Frequence 60 Hz
OFF Channel 1 dims
between DMX-
Level 0-255
Channel 2 dims
between DMX-
Level 0-255
Channel 3 dims
between DMX-
Level 0-255
Channel 4 dims
between DMX-
Level 0-255
Channel 5 dims
between DMX-
Level 0-255
Channel 6 dims
between DMX-
Level 0-255
6 Channel modus
at 300 W
max. workload
dimmer curve
1Fixed frequency 50 Hz 9

DMX-Addressing
You can set your DMX-Start-Address via the 3 address switches. The start address will be set
decimally. For example, if you put the wheels on the position „1“, „5“, „3“ - you set the dimmer
start address on DMX channel 153.
If all 3 address switches are set on 0you are in the Auto-Addressing Mode.
The Auto Addressing will be discoverd only once during the boot sequence of the dimmer. Any
changes will be effective only after a restart of the dimmer.
At the Auto Addressing mode the needed 6 DMX Channel (channel bundle mode are only 3
DMX channels are ltered) are not shown on the DMX output.
Auto Addressing
Manual DMX Addressing
D

Important: All daisy chained DMX devices must be setted on „auto address“ mode.
DMX of the lighting control
DMX of the lighting control
Address
0, 0, 0
Address
1, 5, 3
Address
0, 0, 0
Address
1, 5, 9
Example for Auto Addressing
Example for Manual DMX Addressing
11

Dimmer Curves
Dimmer Curve 1
Dimmer Curve 2
To set dimmer curve 1 you have to put the DIP switch 8on position OFF.
To set dimmer curve 2 you have to put the DIP switch 8on position ON.
G

„Start-Up“ Test Sequence
On each start-up the DMX2DIM runs a self-test sequence. The fan will start-up shortly to check
its function. Each channel is equipped with bicolor LED (green/red).
The Green LED is showing the actually load in coherence to the DMX signal.
Fan control
According to the compact dimmer housing and the resulting power loss the DMX Dimmer
needs an active Cooling System realized with a fan. The fan only turns on if required.
Additionally, temperature within the housing is measured. If the dimmer temperature rises
above 50 Degree Celsius the fan will be turned on. If temperature is below 40 degrees celsius
the fan will be turned off. Therefore, the hysteresis has a temperature of 10 degrees celsius.
Emergency Shutdown
To avoid any damages on the dimmer caused by over heating, the DMX dimmer has an
“emergency shutdown“ sequence. If the PCB temperature rises above 70 Degree Celsius, the
DMX dimmer will locked and all output channels will be shut down. When the PCB cools down
below 55 degree celsius, the dimmer will unlock all channels again. Therefore, the hysteresis
has a temperature of 15 degrees celsius. During the Emergency Shut down Sequence the RED
LED will be on!
Short Circuit Protection
The dimmer is equipped with an internal electronic fuse which protects the dimmer on the
outputs against overload and short circuit. If there is an overload or short circuit on a single
output channel, the dimmer will shut down and lock this channel immediately. To unlock these
channels you have to reboot the cimmer again.
Limited Warranty
We guarantee this product for 24 months.
Miscellaneous and Trouble-Shooting
13

Power
K 1 K 2 K 3 K 4 K 5 K 6
www.lightlife.de
DMX
1
DMX
10
DMX
100
RJ-45
DMX IN RJ-45
DMX OUT
120
Ohm
DMX2DIM
Kanal 1
! AC 230V 50/60 Hz, max. 6 x 300 VA Nicht für induktive Last - not for inductive load !
PE ~` ~ PE ~` ~
Netz DIP/Funktion
1 10
6 Kanal Dimmer-/Switchpack
Kanal 2
PE ~` ~
Kanal 3
PE ~` ~
Kanal 4
PE ~` ~
Kanal 5
PE ~` ~
Kanal 6
PE ~` ~
+ +- -
DMX IN DMX OUT
dimmer_label_messe_ohne_luefter.indd 1 26.10.2010 17:50:08
Connection of load circuits
Maximal load of 6 Channel Mode on each output is 300 VA.
Not for use of inductive loads!
Power feed in via DB with accordingly
switch gear (Breaker 16A B).
The neutral cores from feed in are not
allowed to connect with the neutral core
of the dimmer channel.
E

Power
K 1 K 2 K 3 K 4 K 5 K 6
www.lightlife.de
DMX
1
DMX
10
DMX
100
RJ-45
DMX IN RJ-45
DMX OUT
120
Ohm
DMX2DIM
Kanal 1
! AC 230V 50/60 Hz, max. 6 x 300 VA Nicht für induktive Last - not for inductive load !
PE ~` ~ PE ~` ~
Netz DIP/Funktion
1 10
6 Kanal Dimmer-/Switchpack
Kanal 2
PE ~` ~
Kanal 3
PE ~` ~
Kanal 4
PE ~` ~
Kanal 5
PE ~` ~
Kanal 6
PE ~` ~
+ +- -
DMX IN DMX OUT
dimmer_label_messe_ohne_luefter.indd 1 26.10.2010 17:50:08
To create more work load on the dimmer you can set the dimmer to the bundle mode.
Hereby, two channels which lay side by side will be combined to one single channel. Thus, the
following channels will be combined: channel 1/2, channel 3/4 and channel 5/6.
This function will be activated to “ON” via DIP-switch 7.
On Activation you have 3output channels with a maximal work load of 600W per Channel.
Thereby, the maximal work load will be doubled.
Important: On Bundle Mode the connected output channels have to be wired simultaneously on
their outputs.
Channel bundle
15

Cologne
Berlin
Vienna
LightLife Gesellschaft für audiovisuelle Erlebnisse mbH
Engerthstraße 150/9/3,1020 Vienna
Phone +43 (0) 1 – 218 17 68,Fax +43 (0) 1 – 216 02 33
www.lightlife.at
LightLife Gesellschaft für audiovisuelle Erlebnisse mbH
Urbanstr. 64,2. Hinterhof, 1. OG,10967 Berlin
Phone +49 (0) 30 – 695 678 37,Fax +49 (0) 30 – 695 678 39