manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Leviton
  6. •
  7. Dimmer
  8. •
  9. Leviton VZM10-1L User manual

Leviton VZM10-1L User manual

Single Pole (One location) or 3-Way (Multi-location)
Magnetic Low-Voltage Dimmer
Cat. No. VZM1
Ø
-1L, 1000VA (Lighted)
120VAC, 60Hz
INSTALLATION INSTRUCTIONS
DI-000-VZM10-02C
ONOFF
ONOFF
ONOFF
ONOFF
ONOFF
ONOFF
ONOFFONOFF
ONOFF
ONOFF
ONOFF
ONOFF
2
4
3
1
2
4
1
5
3
3-Way
1. Line or Load
(See IMPORTANT note)
2. Neutral
3. Ground
4. First Traveler – note color
5. Second Traveler – note color
NOTE: For matching remote w/LEDs installation,
the First Traveler becomes Line Hot.
WIRING DIMMER:
Connect wires per WIRING DIAGRAM as follows:
WARNING: CONNECT A MAGNETIC LOW-VOLTAGE
DIMMER ONLY TO THE PRIMARY (HIGH-VOLTAGE) SIDE
OF A MAGNETIC LOW-VOLTAGE TRANSFORMER.
•Green or bare copper wire in wall box to Green dimmer
lead.
• Line Hot wall box wire to Black dimmer lead.
• Load wall box wire to Red dimmer lead.
• Yellow/Red dimmer lead should have Red insulation label
affixed. NOTE: If insulating label is not affixed to Yellow/Red
dimmer lead, use electrical tape to cover.
• Proceed to Step 5.
Hot (Black)
Neutral (White)
Load
Dimmer
Black
Black
White
Red
Green
Ground
Line
120VAC, 60Hz
Yellow/Red
(PRIMARY SIDE OF
MAGNETIC LOW-VOLTAGE
TRANSFORMER)
}
Insulating
Label
4
3
2
1
Insulating Label:
This wire is used in 3-way installations only.
For single pole installations, do not remove this
insulating label.
Black
Green
Red
Yellow/Red
Dimmer
WARNINGS AND CAUTIONS:
• To be installed and/or used in accordance with appropriate electrical codes and regulations.
• If you are unsure about any part of these instructions, consult a qualified electrician.
• To avoid overheating and possible damage to this device and other equipment, do not install to control a receptacle, fluorescent lighting, a motor- or a transformer-
operated appliance.
• Use with magnetic low-voltage transformers, incandescent, or 120V halogen fixtures only. Use a Leviton electronic low-voltage dimmer to control electronic
(solid state) low-voltage transformers.
• When magnetic low-voltage circuits are operated at a dim level, with all lamps inoperative, excess current may flow through the transformer. To avoid possible
transformer failure due to overcurrent, use a transformer that incorporates thermal protection or a fuse at the primary windings.
• Vizia™ dimmers are not compatible with standard 3-way or 4-way switches. They must be used with compatible Vizia™ remotes for multi-location dimming.
WARNINGS AND CAUTIONS:
• Use only one (1) Vizia™ dimmer in a multi-location circuit with up to 9 coordinating remotes without LEDs or up to 4 matching remotes with LEDs.
The remote(s) will turn the light on at the brightness level selected at the dimmer.
• Total minimum load must exceed 40W.
• Dimmer may feel warm to the touch during normal operation.
• Recommended minimum wall box depth is 2-1/2”.
• Maximum wire length from dimmer to all installed remotes cannot exceed 300 ft.
• Disconnect power at circuit breaker or fuse when servicing, installing or removing fixture.
• Use this device only with copper or copper clad wire. With aluminum wire use only devices marked CO/ALR or CU/AL.
Single-Pole
1. Line (Hot)
2. Neutral
3. Ground
4. Load
INSTALLING YOUR DIMMER
NOTE: Use check boxes when Steps are completed.
√
3-Way Wiring with Coordinating Dimming or
Switching Remote (no LEDs) Application:
BK
YL/RDRD
4
3
2
5
Black
Green
Red
Yellow/Red
1
Coordinating Remote
2
4
3
5
1
Dimmer
WIRING DIMMER:
Connect wires per WIRING DIAGRAM as follows:
WARNING: FOR MAGNETIC LOW-VOLTAGE APPLICATIONS, CONNECT
DIMMER ONLY TO THE PRIMARY (HIGH-VOLTAGE) SIDE OF A
MAGNETIC LOW-VOLTAGE TRANSFORMER.
NOTE: When using the coordinating remote without LEDs, the dimmer can
be installed on either the Line or Load side of the 3-way circuit.
NOTE: Maximum wire length from dimmer to all installed remotes cannot
exceed 300 ft.
•Green or bare copper wire in wall box to Green dimmer lead.
• Line Hot (common) wall box wire identified (tagged) when removing old
switch to Black dimmer lead.
• First Traveler wall box wire to Red dimmer lead (note wire color). This
traveler from the dimmer must go to the terminal screw on the remote
marked “RD”.
• Remove Red insulating label from Yellow/Red dimmer lead.
• Second Traveler wall box wire to Yellow/Red dimmer lead (note wire
color). This traveler from the dimmer must go to the terminal screw on the
remote marked “YL/RD”.
Hot (Black)
Neutral (White)
Load
Dimmer
Coordinating Remote (no LEDs)
YL/RD Yellow/
Red
RD
WH
Red
Black
BK
Black
Do not use for
incandescent
applications.
White
Line
120VAC, 60Hz
Green
Ground
Green
Ground
(PRIMARY SIDE OF
MAGNETIC LOW-VOLTAGE
TRANSFORMER)
}
(Coordinating Dimming Remote Depicted)
IMPORTANT: For 3-Way applications, note that one of the screw
terminals from the old switch being removed will usually be a
different color (Black) or labeled Common. Tag that wire with
electrical tape and identify as the common (Line or Load) in both the
dimmer wall box and remote wall box.
Step 2 cont’d
• Pull off pre-cut insulation from dimmer leads.
• Make sure that the ends of the wires from the wall box are
straight (cut if necessary).
• Remove insulation from each wire in the wall box as shown.
• For Single-Pole Application, go to Step 4a.
• For 3-Way Coordinating Remote (no LEDs) Application, go
to Step 4b.
• For 3-Way Matching Remote (with LEDs) Application, go
to Step 4c.
WIRE NUT / # OF CONDUCTOR
COMBINATION CHART
1- #12 w/ 1 to 3 #14, #16 or #18
2- #12 w/ 1 or 2 #16 or #18
1- #14 w/ 1 to 4 #16 or #18
2- #14 w/ 1 to 3 #16 or #18
For non-standard wiring applications, refer
to Wire Nut and Conductor Size Chart
Tools needed to install your Dimmer
Slotted/Phillips Screwdriver Electrical Tape
Pliers Pencil
Cutters Ruler
Push in side at
tab to release
Line up tabs and press
in side to attach
Changing the color of your Dimmer:
Your Dimmer includes three color options. The Dimmer ships with
the White frame attached. To change color of frame, proceed as
follows:
If installing Dimmer in a single device application, proceed with
the INSTALLING YOUR DIMMER section. If installing Dimmer in
a multi-device application, proceed as follows:
MULTI-DEVICE APPLICATION
In multi-dimmer installations, the side sections of the mounting
strap may require removal. Use pliers to carefully bend side
sections back and forth until they break off.
Installing Dimmer by itself or with other devices
MAXIMUM LOAD PER DIMMER FOR MULTI-DEVICE
Load
Mag LV 1000VA
Single
800VA
Two Devices
650VA
More than
2 Devices
MAXIMUM BULB WATTAGE
Low-voltage dimmers are rated in Volt-Amps (VA). The maximum bulb
wattage is determined by the efficiency of the transformer in the low-
voltage lighting system. Transformer efficiencies will vary from different
manufacturers; consider 75% efficient as average. Use the chart to
determine maximum bulb wattage for typical transformer efficiency ratings.
WARNING: TO AVOID FIRE, SHOCK, OR DEATH;
TURN OFF POWER at circuit breaker or fuse and test
that power is off before wiring!
Step 2 Identifying your wiring application
(most common):
NOTE: If the wiring in the wall box does not resemble any
of these configurations, consult a qualified electrician.
Step 1
MAXIMUM BULB WATTAGE AT 75% EFFICIENCY
Rating
1000VA 750W
Single
600W
Two Gang
525W
More than
2 Gang
Strip Gage
(measure bare
wire here or use
gage on back of
the dimmer)
Preparing and connecting wires:
Step 3
5/8”
(1.6 cm)
Single-Pole Wiring Application:
Step 4a Step 4b
Typically, removal of the side sections in multi-dimmer
installations requires a reduction of the dimmer’s capacity. Refer
to the chart for maximum load per dimmer.
Remove
all inner
side
sections
Do not
remove
outer
side
sections
Bend back and
forth to remove
side section
To Program:
NOTE: Have a flashlight handy if
this dimmer controls the only light
source in the room.
1. On the dimmer only, engage the
air-gap switch by gently pulling
the bottom of the push pad
until it lifts completely out of the
frame and a click is heard and
all LED’s are OFF.
2. Press push pad back into
frame and hold push pad for 7
seconds until the locator light
and the top LED (LED 1) starts
blinking.
3. Upon releasing the push pad, the locator light will continue to
blink once per second indicating the dimmer is in Mode 1, Set
Minimum Brightness mode. To change the current Minimum
Brightness level from 1-50%, use the DIM/BRIGHT Bar. This
setting will automatically be saved.
4. Tap the push pad to change to Mode 2, Set Dim-Lock
Level mode. The locator light will blink twice per second. To
change the current Set Dim-Lock level from 1-100%, use the
DIM/BRIGHT Bar. If this feature is not desired, press and hold
the lower half of the DIM/BRIGHT Bar until no LED is lit. This
setting will automatically be saved.
5. Tap the push pad to change to Mode 3, Set Fade Rate mode.
The locator light will blink 3 times per second. To change the
current Fade Rate, use the DIM/BRIGHT Bar to move the LED
to the desired preset level. This setting will automatically be
saved by tapping the push pad to exit programming mode.
The LED Brightness Display is separated into 7 segments. Each
LED represents a preset level with LED 1 (Preset 1) located at the
top and LED 7(Preset 7) located at the bottom. Refer to chart for
settings and defaults.
NOTE: The dimmer will exit program mode after 3 minutes of
inactivity.
LIMITED 5 YEAR WARRANTY AND EXCLUSIONS
Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale by Leviton is free of defects in materials and workmanship under normal and proper use for five years from the purchase date. Leviton’s only obligation is to correct such defects by repair or replacement, at its option, if within such five year period the product is returned prepaid, with proof
of purchase date, and a description of the problem to Leviton Manufacturing Co., Inc., Att: Quality Assurance Department, 59-25 Little Neck Parkway, Little Neck, New York 11362-2591. This warranty excludes and there is disclaimed liability for labor for removal of this product or reinstallation. This warranty is void if this product is installed improperly or in an improper environment, overloaded, misused,
opened, abused, or altered in any manner, or is not used under normal operating conditions or not in accordance with any labels or instructions. There are no other or implied warranties of any kind, including merchantability and fitness for a particular purpose, but if any implied warranty is required by the applicable jurisdiction, the duration of any such implied warranty, including merchantability and fitness
for a particular purpose, is limited to five years. Leviton is not liable for incidental, indirect, special, or consequential damages, including without limitation, damage to, or loss of use of, any equipment, lost sales or profits or delay or failure to perform this warranty obligation. The remedies provided herein are the exclusive remedies under this warranty, whether based on contract, tort or otherwise.
Hot (Black)
Neutral (White)
Dimmer
Matching Remote
(with LEDs)
YL/RD
Yellow/
Red
Red
WH BK
Black Black
White
Line
120VAC, 60Hz
Green
Ground
Green
Ground
Load
(PRIMARY
SIDE OF
MAGNETIC
LOW-VOLTAGE
TRANSFORMER)
}
Gently lift bottom
of push pad out
• Restore power at circuit breaker or
fuse.
• Press pad until locator light is OFF.
Lights should turn ON. If lights do
not turn ON, press the upper half of
the DIM/BRIGHT Bar until the lights
brighten.
If lights still do not turn ON, refer to
the TROUBLESHOOTING section.
3-Way Wiring with Matching Remote
(w/LEDs) Application:
BK
YL/RD
WH
4
3
2
5
Additional
Neutral Wire
Matching Remote Dimmer
4
3
5
1
2
Black
Green
Red
Yellow/Red
1
DI-000-VZM10-02C
NOTE: Dress wires
with a bend as shown
in diagram in order to
relieve stress when
mounting device.
•Position all wires to provide room
in outlet wall box for device.
• Ensure that the word “TOP” is
facing up on device strap.
• Partially screw in mounting screws
in wall box mounting holes.
Push Pad (Default settings)
Turn ON from OFF position:
Tap – Lights turn ON to preset level.
Press and Hold – Lights turn ON to full
bright.
Turn OFF from ON position:
Tap – Lights turn OFF.
DIM/BRIGHT Bar
BRIGHTEN:
Press upper half of DIM/BRIGHT Bar
– Lights brighten to desired level.
DIM:
Press lower half of DIM/BRIGHT Bar
– Lights dim to desired level.
If you continue to hold, the lights will DIM
to minimum level and then turn OFF.
NOTE: When lights are OFF, the turn ON
light level can be changed by using the
DIM/BRIGHT Bar.
If there is a power outage, when the
power is restored the lights will return
to the last setting before the power
interruption.
LED Brightness
Display
DIM/BRIGHT
Bar
Push
Pad
Locator
Light
Mode Description Range Default
1 Set Min. Brightness 1-50% 25%
2 Set Dim-Lock Level 0-100%, 0=no lock 0
3 Select Fade Rate 1, 2, 3, 4, 5, 6 or 7 Preset #1
Advanced Features Summary
* default
** LED #1 is located at the top
Preset LED** Fade On Fade Off
1*1 Approx. 1.5s from full off Approx. 3s from full on
2 2 No Fade No Fade
3 3 No Fade Approx. 3s from full on
4 4 Approx. 0.5s from full off Approx. 3s from full on
5 5 Approx. 0.5s from full off Approx. 1.5s from full on
6 6 Approx. 1.5s from full off Approx. 5s from full on
7 7 Approx. 1.5s from full off Approx. 10s from full on
Fade Rate Presets
1
2
3
4
5
6
7
LED
Brightness
Display
WIRING DIMMER (wall box with Load connection):
Connect wires per WIRING DIAGRAM as follows:
WARNING: FOR MAGNETIC LOW-VOLTAGE APPLICATIONS,
CONNECT DIMMER ONLY TO THE PRIMARY (HIGH-VOLTAGE)
SIDE OF A MAGNETIC LOW-VOLTAGE TRANSFORMER.
•Green or bare copper wire in wall box to Green dimmer lead.
• Load wall box wire identified (tagged) when removing old switch to
Red dimmer lead.
• First Traveler Line Hot to Black dimmer lead.
• Remove Red insulating label from Yellow/Red dimmer lead.
• Second Traveler wall box wire (note color as above) to Yellow/
Red dimmer lead. This traveler from the dimmer must go to the
terminal screw on the remote marked “YL/RD”.
• Proceed to Step 5.
WIRING COORDINATING REMOTE:
Connect wires per WIRING DIAGRAM as follows:
NOTE: Maximum wire length from dimmer to last remote is 300ft.
•Green or bare copper wire in wall box to Green terminal screw.
• Load wall box wire identified (tagged) when removing old switch
to terminal screw marked “BK”.
• First Traveler wall box wire (note color as above) to terminal
screw marked “RD”. This traveler from the remote must go to
the Red dimmer lead.
• Second Traveler wall box wire (note color as above) to
terminal screw marked “YL/RD”. This traveler from the remote
must go to the Yellow/Red dimmer lead.
• Remote terminal screw marked “WH” should have White
insulation label affixed. NOTE: If insulating label is not affixed to
terminal screw marked “WH”, use electrical tape to cover.
• Proceed to Step 5.
TROUBLESHOOTING
• Lights Flickering
- Lamp has a bad connection.
- Dimmer wires not securely fastened and/or wires not secured
firmly under terminal screws of remote.
• Light does not turn ON and Locator LED does not
turn ON
- Circuit breaker or fuse has tripped.
- Lamp is burned out.
- Lamp Neutral connection is not wired.
• Intermittent dimmer operation
- Minimum load is under 40W.
• Remote does not operate lights
- Ensure that total wire length does not exceed 300 ft.
For additional information, contact Leviton’s
Techline at 1-800-824-3005 or visit Leviton’s
website at www.leviton.com
Covered by one or more US & Foreign
Patents and patents pending
Copyright©2006 Leviton Manufacturing Co., Inc.
All Rights Including Trade Dress Rights Reserved
This equipment has been tested and found to comply with the limits
for a Class B Digital Device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment
generates, uses, and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause
harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the
equipment OFF and ON, the user is encouraged to try to correct
the interference by one or more of the following measures:
• Reorient or relocate the receiving Antenna.
• Increase the separation between the equipment and the
receiver.
• Connect the equipment into an outlet on a circuit different from
that to which the receiver is connected.
• Consult the dealer or an experienced radio/tv technician for
help.
FCC COMPLIANCE STATEMENT
Mode 1 – Set Minimum Brightness: Set the minimum brightness
level that the lights can dim to prior to turning full OFF.
Mode 2 – Set Dim-Lock: Set the brightness level that the lights will
turn on to regardless of the previous light level at which they were
turned OFF.
Mode 3– Set Fade Rate: Set the amount of time (in seconds) that the
lights will have to turn ON or OFF. Fade rates can be set to one of five
different settings.
ADVANCED PROGRAMMING FEATURES
NOTE: The locator light will illuminate when the load is in the OFF
position to facilitate access in the dark.
NOTE: If using the dimmer in a 3-way application, the lights will turn
Air-Gap Switch: On the dimmer only,
engage the air-gap switch by gently pulling
the bottom of the push pad until it lifts
completely out of the frame and a click
is heard and all LED’s are OFF (refer to
Figure). This will cut power to the fixture to
replace the bulb. After servicing is complete,
push the push pad back for normal
operation.
Cleaning: Clean with a damp cloth. DO
NOT use chemical cleaners.
OPERATION
Testing your Dimmer prior to mounting in
wall box:
Step 5
Installation may now be completed by
tightening mounting screws into wall box.
Attach wallplate.
Dimmer Mounting:
TURN OFF POWER AT CIRCUIT BREAKER OR FUSE.
Step 6
Restore Power: Restore power at circuit breaker or
fuse. Installation is complete.
Step 7
NOTE: The dimmer must be installed in a wall box that has a Load
connection. The matching remote must be installed in a wall box
with a Line Hot connection and a Neutral connection. A Neutral
wire to the matching remote needs to be added as shown.
If you are unsure about any part of these instructions, consult a
qualified electrician.
NOTE: Maximum wire length from dimmer to all installed remotes
cannot exceed 300 ft.
WIRING MATCHING REMOTE (wall box with Line Hot
connection):
Connect wires per WIRING DIAGRAM as follows:
• Line Hot (common) wall box wire identified (tagged) when
removing old switch and First Traveler to dimmer terminal screw
marked “BK”.
• Second Traveler wall box wire from dimmer to remote terminal
screw marked “YL/RD” (note wire color). This traveler from the
remote must go to the terminal screw on the dimmer marked
“YL/RD”.
• Line Neutral wall box to remote terminal screw marked “WH”.
Step 4c

Other Leviton Dimmer manuals

Leviton VZH06-7L User manual

Leviton

Leviton VZH06-7L User manual

Leviton DDS 6000+ User manual

Leviton

Leviton DDS 6000+ User manual

Leviton LumaCan DRDDP User manual

Leviton

Leviton LumaCan DRDDP User manual

Leviton i Series e User manual

Leviton

Leviton i Series e User manual

Leviton a-2000 User manual

Leviton

Leviton a-2000 User manual

Leviton I 24 Manual

Leviton

Leviton I 24 Manual

Leviton VZX12-7L User manual

Leviton

Leviton VZX12-7L User manual

Leviton DDS8800 Operating instructions

Leviton

Leviton DDS8800 Operating instructions

Leviton 06674 User manual

Leviton

Leviton 06674 User manual

Leviton Lumina ZS057-ALZ User manual

Leviton

Leviton Lumina ZS057-ALZ User manual

Leviton Vizia RF RZI06-1L User manual

Leviton

Leviton Vizia RF RZI06-1L User manual

Leviton Decora Mural MDE03-1 User manual

Leviton

Leviton Decora Mural MDE03-1 User manual

Leviton 6628 User manual

Leviton

Leviton 6628 User manual

Leviton NSI DS8 Operating instructions

Leviton

Leviton NSI DS8 Operating instructions

Leviton VZE04-1L User manual

Leviton

Leviton VZE04-1L User manual

Leviton Acenti ACX10-1L User manual

Leviton

Leviton Acenti ACX10-1L User manual

Leviton LumaCan DRDDP User manual

Leviton

Leviton LumaCan DRDDP User manual

Leviton RZP03-1LW Installation instructions

Leviton

Leviton RZP03-1LW Installation instructions

Leviton DDS5300 Operating instructions

Leviton

Leviton DDS5300 Operating instructions

Leviton RZCZ1 User manual

Leviton

Leviton RZCZ1 User manual

Leviton Decora Illumatech IPI06-1L User manual

Leviton

Leviton Decora Illumatech IPI06-1L User manual

Leviton decora IP710-LF User manual

Leviton

Leviton decora IP710-LF User manual

Leviton Vizia RZI6-1L User manual

Leviton

Leviton Vizia RZI6-1L User manual

Leviton QuickPort User manual

Leviton

Leviton QuickPort User manual

Popular Dimmer manuals by other brands

QUBINO ZMNHWD1 user manual

QUBINO

QUBINO ZMNHWD1 user manual

City Theatrical QolorFLEX 5809 quick start guide

City Theatrical

City Theatrical QolorFLEX 5809 quick start guide

Chauvet COLORado 6 Quick reference guide

Chauvet

Chauvet COLORado 6 Quick reference guide

RC4 Wireless LumenDimM6 quick start guide

RC4 Wireless

RC4 Wireless LumenDimM6 quick start guide

Sunricher Universal Series quick start guide

Sunricher

Sunricher Universal Series quick start guide

Candeo Zigbee C201 quick start guide

Candeo

Candeo Zigbee C201 quick start guide

Zennio Lumento X2 v2 quick start guide

Zennio

Zennio Lumento X2 v2 quick start guide

Anslut 400-821 User instructions

Anslut

Anslut 400-821 User instructions

Megaman Connect JSJSLW450 instruction manual

Megaman

Megaman Connect JSJSLW450 instruction manual

CHERUBINI A510073 instructions

CHERUBINI

CHERUBINI A510073 instructions

Yokis MTV150EBRP manual

Yokis

Yokis MTV150EBRP manual

Elation PRO BAR 4 User instructions

Elation

Elation PRO BAR 4 User instructions

LSC ePRO DMX512 Operator's manual

LSC

LSC ePRO DMX512 Operator's manual

thomann StairVille DDS 405 user manual

thomann

thomann StairVille DDS 405 user manual

IKEA RODRET manual

IKEA

IKEA RODRET manual

AMX Dual Incandescent Dimmer Module RDM-2INC Installation sheet

AMX

AMX Dual Incandescent Dimmer Module RDM-2INC Installation sheet

Dove Lighting Systems DimmerMaster user manual

Dove Lighting Systems

Dove Lighting Systems DimmerMaster user manual

WorkPro WD 2012 DMX user manual

WorkPro

WorkPro WD 2012 DMX user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.