LightwaveRF JSJS LW107 User manual

Professional Series
Instruction manual
PIR Sensor
www.lightwaverf.com
LW107

EC DECLARATION OF CONFORMITY
Responsible Authority:
LightwaveRF PLC,
Innovation Campus Birmingham
Faraday Wharf
Holt Street
Birmingham
B7 4BB
Tel: +44 (0)121 250 3625
Model Number(s): JSJSLW107
Description: PIR Sensor
Directives this equipment
Complies with: 2006/95/EC The Low Voltage Directive N/A
2004/108/EEC The Electromagnetic Compatibility Directive
1999/5/EC R&TTE Directive
93/68/EEC CE Marking Directive
Standards Applied in order to verify compliance
Safety: BS EN 60730-1: 2011
Health:
R&TTE: EN 301 489-1 V1.9.2: (2011-09), EN 301 489-3 V1.4.1: (2002-08)
EN 300 220-1 V2.1.1: 2006, EN 300 220-2 V2.1.2: 2007
EMC: EN 301 489-1 V1.9.2: (2011-09), EN 301 489-3 V1.4.1: (2002-08),
EN 55022: 2010, EN 61000-3-2: 2006 +A1: 2009 +A2: 2009 Class A,
EN 61000-3-3: 2008, EN61000-4-2: 2009,
EN 61000-4-3: 2006 +A1: 2008 +A2: 2010, EN 61000-4-4: 2012,
EN 61000-4-5: 2006, EN 61000-4-6: 2009, EN 61000-4-11: 2004
For and on behalf of LightwaveRF PLC
----------------------------------------
Name J Shermer
Position Managing Director

How does it work?
How do I get started?
Please refer to the following installation and
setup instructions that will guide you through
the installation and setup process.
The PIR will trigger a LightwaveRF device when
it senses movement. It can be positioned
anywhere (indoors). To install it, you will need
simply to apply the adhesive strips provided and
attach the PIR to a wall or flat surface. You can
also mount the PIR to a standard back-box or flat
surface using suitable screws (not included).
Help video & further guidance
For additional guidance, and to watch a video
that will help guide you through the installation
process, please visit the support section on
www.lightwaverf.com
Get Started

IMPORTANT: Please retain these instructions for guidance on how to link
other LightwaveRF receivers. For additional guidance please visit
www.lightwaverf.com
Main sensor lens
(lens cover not
shown)
Main unit
Metal surround
Overview
Installation

NOTE: It is important to install this product in accordance with the following
instructions. Failure to do so may void your warranty.
LightwaveRF is fully legal to install in your own home. However, if in doubt,
always consult a qualified electrician.
Installation
Delay Slider
Screw Mounting
holes
Learn Slider
Lux Slider
Battery
Compartment
Installation

Inserting/replacing batteries & accessing sliders
To insert or replace the batteries, the main PIR unit must be removed from
the base section. Removing the main unit from the base will also allow
access to the rear sliders (which change the PIR settings) without having to
detach the base from the wall once the PIR has been attached.
1. Carefully remove the frame by inserting a flat head screwdriver into the
slot and lift away from the unit.
Installation

2. Insert the screwdriver under
the tab situated at the bottom of
the main unit as shown. Gently
remove the main unit from the
base.
4. Replace the main unit and
clip the faceplate back into
place. Make sure that the
faceplate hooks in from the top
first. A sharp click will indicate
that the plate has been success-
fully replaced.
3. The battery compartment is
located on the rear of the main
unit. Two AAA batteries are
required to power the unit.
Installation

Setting the detection angle
Setting the detection angle will
determine the area in which the
presence of movement will trigger
the PIR. This angle can be altered by
adding the lens covers that partially
cover the sensor lens.
The lens covers can be cut in order to
alter the angle of detection. The
more that is cut away, the wider the
detection angle.
Vertically, the maximum detection
angle is always 65 degrees. Horizon-
tally, the maximum detection angle is
80 degrees without lens covers and
20 degrees with the lens covers.
Installation

To mount the PIR, insert
suitable screws into the
mounting holes and
screw to the wall. The
main unit must be
removed from the base in
order to perform this task.
Alternatively, place the
adhesive strips along the
rear sides of the surround
and attach to the wall.
Wall mounting the PIR
The PIR is designed to be wall mounted (although it can be positioned
anywhere indoors) using the adhesive strips provided or suitable screws.
NOTE: Before permanently mounting the PIR, it is important to ensure
that the location is suitable for the nature of the operation required and
that the unit is setup and working as desired.
Installation

The PIR sensor will trigger any LightwaveRF receiver, such as a dimmer
switch or a power socket, to which it is ‘linked’. It is possible to link a PIR to
as many LightwaveRF devices as desired as long as they are within its range
(approx. 10-15m indoors under normal conditions).
Setup
Linking the PIR to a
LightwaveRF device
1. Place the LightwaveRF device that you
wish to control in ‘linking’ mode. For
information on how to do this please refer
to the instruction manual for that specific
LightwaveRF device.
2. Whilst the LightwaveRF device is in
linking mode, move the slider marked
‘Learn’ on the rear of the PIR to its
opposite position. The LED light on the
target device will flash to confirm that the
PIR is linked. This process can be repeated
to control multiple devices from one PIR.
Learn
slider
Device setup

Sending ‘on’ or ‘on & o’ commands
Once the PIR is linked, moving the ‘learn’ slider to the position marked ‘1’
will turn on any linked devices when the PIR is triggered. Moving the slider
to the ‘1/0’ position will turn on linked devices, but also send an ‘o’
command after a customisable delay period (see next section).
Unlinking the PIR from a
LightwaveRF device
1. Place the LightwaveRF device that you
wish to remove in ‘linking’ mode. For
information on how to do this please refer
to the instruction manual for that specific
LightwaveRF device.
2. Whilst the LightwaveRF device is in
linking mode, move the slider marked
‘learn’ on the rear of the PIR to its opposite
position. The LED light on the target
device will flash to confirm that the PIR is
unlinked.
Learn
slider
Device setup

If the learn slider is set to ‘1/0’, then an ‘o’
command will be sent to a linked Lightwa-
veRF device after the initial ‘on’ command
sent by the PIR. The period of time between
these two commands can be customised
using the ‘Time delay’ slider. It has 4
positions: 5 sec/1 min/5 min/10 min. The
delay countdown will begin once movement
is no longer detected after the initial ‘on’
command has been sent.
Setting the ‘o’ command delay
Time
delay
slider
Setting the light sensitivity
Setting the light sensitivity on the PIR
sensor determines the light level at which
the PIR sensor will become active. The
sensitivity can be set by moving the position
of the lux slider marked ‘H/M/L’.
Lux
slider
Device setup

The slider has 3 positions: ‘H/M/L’.
• In position ‘H’ the PIR will be active at all light levels.
•In position ‘M’ the PIR will only become active at low daylight levels.
•In position ‘L’ the PIR will only become active in darkness (or very low light).
NOTE: When adjusting the Lux setting it may take up to 30 seconds for the
PIR to acclimatise to the new light setting.
Finalising setup
Once the PIR has been linked to its target LightwaveRF devices and the
settings adjusted, it can be mounted in its final position. Once in position, it
is important to allow at least 30 seconds for the PIR to acclimatise to the
light level in its new environment. Until this process has taken place, the unit
may not perform as expected.
Battery low indicator
The ‘battery low’ indicator is positioned inside the sensor lens. If the battery
is low, the indicator will blink after the PIR has sent a command to inform
that the batteries need changing.
Device setup

1. (Easy): Nighttime safety
Required: PIR / plug-in sockets or dimmer
A PIR can be set to be active only during the hours of darkness. You can
therefore position the sensor on an upstairs landing or in a hallway and use
it to automatically turn on a LightwaveRF dimmer or plug-in at night. If the
kids get up to use the bathroom in the middle of the night, the sensor will be
triggered and the hall light and bathroom can be set to automatically light
up. Best of all, once they are safely back in bed, the PIR will automatically
turn those lights o again.
Creative ideas

Problem: The PIR will not link to LightwaveRF devices.
Solution: The PIR may be encountering interference or may be at the edge
of its reliable range of operation. First, ensure that there are no large pieces
of metal, very thick walls or bodies of water in the path of the transmission.
If the problem persists, try moving the PIR closer to the socket, or consider
using a LightwaveRF Signal Booster to extend the range by relaying the
signal between the PIR and target device.
Problem: The PIR will not / no longer triggers any LightwaveRF devices.
Solution: Change the batteries. A weak battery signal is indicated by a red
LED light on the sensor lens illuminating after triggering. Please note: if the
battery is totally expended, the red light may not illuminate so checking the
batteries is always advisable even if no red light is visible.
Problem: The PIR triggers randomly / unexpectedly.
Solution: Check the battery strength: if the battery strength is low, the PIR
can behave erratically. Alternatively, ensure that the field of vision of the
sensor is not interrupted by anything that could move and/or emit heat (e.g.
animals / spider on lens / heat rise from nearby radiator).
Troubleshooting

Problem: The PIR still operates in daylight despite being set to only
operate in darkness.
Solution: The PIR sensor may be located in a dark or shadowy place despite
the general light level being high. Consider repositioning the PIR.
Problem: The PIR does not send the ‘o’ command after the specified
delay period.
Solution: The delay period countdown is only started once no more
movement (heat based) is detected. It may be the case that the ‘o’
command is not being sent because the delay period is constantly being
reset by further movement.
Problem: A LightwaveRF device has been turned o manually after being
triggered by the PIR, however, the PIR is now not working.
Solution: Is there an automatic time delay set on the PIR? If so, even though
the linked LightwaveRF devices have been turned o manually, the PIR will
still be waiting to send an ‘o’ command. It will not turn on any devices again
until the ‘o’ command has been sent after the set delay period has ended.
Troubleshooting

Q. How long does the PIR battery last?
A. This depends on use, but 9-12 months is a reliable average.
Q. How do I know if the battery needs changing?
A. A red light in the sensor lens will flash after the PIR has sent a command.
Q. Can I control multiple devices with one PIR?
A. Yes, you can link as many LightwaveRF receiver devices (such as
dimmers and sockets) as you wish to the same PIR.
Q. Can i have more time delay and light settings?
A. No, only the settings denoted by the sliders are possible.
Q. Can the PIR be mounted outdoors?
A. The PIR is not waterproof, therefore this is not recommended.
Q. Is it legal for me to install LightwaveRF devices myself?
A. Yes, Lightwave products are fully legal to install in your own home.
Q. Is it common for the sensor to be accidentally triggered?
A. All PIR sensors can be accidentally triggered, however they work by
detecting heat, rather than movement, so people and larger animals will
trigger the sensor, whereas other objects generally will not.
FAQs

Specification
RF frequency: 433.92 MHz
Output rating: 3V
Batteries: 2x AAA
Mounting: Standard single back-box, sticky pads or screw to wall
Dimensions: Width 88mm, Height 88mm, Depth 27mm
Warranty: 2 year standard warranty
Technical Specification

www.lightwaverf.com
Innovation Campus Birmingham
Faraday Wharf
Holt Street
Birmingham
B7 4BB
Version 2.3
Other manuals for JSJS LW107
1
Table of contents
Other LightwaveRF Accessories manuals
Popular Accessories manuals by other brands

Vega
Vega VEGASON 62 operating instructions

EVERSPRING
EVERSPRING SP818 user manual

American DJ
American DJ EURO FOG JUICE Material safety data sheet

Artillian
Artillian 1RMBCH Installation & owner's manual

Seifert
Seifert SlimLine Pro KG 8412 instruction manual

Summer
Summer TUB TIME BUBBLE MAKER instruction manual