Step 4 Connect Power and Camera Control Cables
1. Untighten the right cable gland, insert the AC power cable
through the hole and connect to AC INPUT terminal. Then,
tighten the cable gland(FIG.8).
Warnings & Cautions
Please read the manual before attempting installation or operation
1. Do not use any chemical detergent to clean the machine surface; use a
damp cotton cloth only. Regularly clean the dome cover to ensure
focusing accuracy.
2. Install the Fast Dome in a dry area. Water and high humidity may damage
internal parts. External housing should be used for outdoor installation.
3. Use parts supplied by the manufacturer only; use of unqualified part will
void the warranty.
4. Avoid installing the equipment on an unstable surface. Make sure the
installation location is solid and stable. Falling equipment may injure
personnel and damage the equipment.
5. Do not install the equipment near any flammable gas. Violation may
cause fire or injury.
6. Avoid running video and signal cables through or passing interference
sources such as electromagnetic wave, broadcast station, power
generator, elevator motor, or high voltage area, etc. Interference may
cause the equipment not to function properly.
7. Make sure the power cable is properly connected. Loosened power
cables may cause serious short circuit or fire.
8. Make sure all cables are properly connected. Do not place any object on
the cables. Replace the cable if damaged. Violation may cause short
circuit, fire, and injury.
9. Make sure all wires and cables are properly grounded to avoid damage
caused by lightning.
10. Do not put any foreign objects inside the equipment and do not spray
any liquid on the equipment to avoid short circuit and subsequent
damage.
11. Do not touch power connection with wet hands to avoid short circuit or
electric shock.
12. Do not apply external force on the equipment. Violation may cause
damage.
13. Do not expose the equipment directly to sunlight. Violation may cause
color fading or damage.
14. Do not install the equipment in high or low temperature environment to
avoid damage. The operating temperature is between -40°C - +50°C.
15. The Fast Dome consists of highly sensitive electronic parts inside. Do
not try to repair the equipment. Only a qualified technician may
disassemble and repair the equipment. Shut off the power before
disassembling the equipment and do not power it on unless the casing
is completely closed.
16. Turn off the power immediately and contact the technician when the
following occurs:
A. Damage on power cable or plug.
B. Water leak into the equipment.
C. Fast Dome does not function normally.
D. Equipment falling on the ground or damage on external casing.
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
CAUTION
TO REDUCE THE RISK OF ELECTRIC SHOCK,
DO NOT REMOVE FRONT OR BACK COVER.
NO USER SERVICEABLE PARTS INSIDE.
FOR MAINTENANCE, CONTACT QUALIFIED
SERVICE PERSONNEL.
CAUTION
RISK OF EXPLOSION IF BATTERY IS REPLACED
WITH AN INCORRECT TYPE.
DISPOSE OF USED BATTERIES ACCORDING
TO THE INSTRUCTIONS
[FIG.8]
EARTH
DC24V
DC OUTPUT
AC INPUT
AC100~240V
2. Untighten the left cable gland, insert the camera control cables
through the hole. Then, insert the control cables, DC power
cable and safety strap through the bracket to connect to the
camera. Then, tighten the cable gland(FIG.9).
For camera control cables connection method and
installation, please refer to the camera instruction manual.
Note:
[FIG.9]
CAUTI O N
When running a cable, please insert one cable through one
cable gland only for better waterproofing. (Recommended)
Cable diameter for the cable gland: 5~12mm
If necessary to insert two cables through one cable gland,
please fill the gap between cables with waterproof glue, for a
reliable waterproof performance.
Step 5 Complete Installation
Tighten the 4 screws back into the PSU box, the installation is now
complete(FIG.10&FIG.11).
[FIG.10] [FIG.11]