Linde Warning Projector 85 pro User manual

Linde Warning Projector 85 pro
02/2023


Ergänzende Nutzungsinformationen: Gerätesteuerungsanschluss 3
1. Bestimmungsgemäßer Einsatz ............................................................................................. 4
2. Technische Übersicht............................................................................................................. 4
3. Lieferumfang ........................................................................................................................... 4
4. Anschließen eines potentialfreien Kontakts oder einer 1–10V Ansteuerung ................... 5
4.1 Gebrauch der Steckverbindung .........................................................................................5
4.2 Belegung............................................................................................................................5
4.3 Verschließen der Steckverbindung ...................................................................................5
5. Aktivierung des Taktschwellers ............................................................................................ 6
5.1 Einsatz der Kabelbrücke....................................................................................................6
5.2 Abschluss der Installation ..................................................................................................6
DEUTSCH
Linde Warning Projector 85 pro
Ergänzende Nutzungsinformationen: Gerätesteuerungsanschluss
Inhaltsverzeichnis

4 Linde Warning Projector 85 pro
1
2
4
3
1. Bestimmungsgemäßer Einsatz
Der Gerätesteuerungsanschluss ist für die fol-
genden zwei Einsätze vorgesehen:
1. Steuerung der Helligkeit des Projektors,
einschließlich dem Ein- und Ausschalten,
über einen potentialfreien Kontakt oder
1–10V Ansteuerung. Der Projektor kann
hierüber mit einer externen Anlage gesteu-
ert werden.
2. Aktivierung des eingebauten Taktschwel-
lers, der ein kontinuierliches Ein- und Aus-
blenden der Projektion ermöglicht. Die Ge-
schwindigkeit und die Intervalle sind vorge-
geben und können nicht verändert werden.
ACHTUNG! Der Projektor kann bei unsachge-
mäßer Verwendung des Gerätesteuerungsan-
schlusses beschädigt werden. Verbinden Sie
den Projektor nur mit geeigneten Steuerungen
und folgen Sie dabei den Anweisungen in den
Nutzungsinformationen.
①Ansteuerung potentialfreier Kontakt/1–10V
②Aktivierung des Taktschwellers
③Gerätesteuerungsanschluss
④Kaltgeräte Einbaustecker
2. Technische Übersicht
3. Lieferumfang
• Runde Steckverbindung, Typ Phoenix Con-
tact SACC-M12FS-5PL: zur Verbindung ei-
ner 1–10V Steuerleitung mit dem Linde
Warning Projector 85 pro.
• Kabelbrücke 40 mm mit Schutzkappe: zur
Aktivierung des eingebauten Taktschwel-
lers.
Ansteuerung potentialfreier Kontakt:
geschlossen = 0% | oen = 100% Helligkeit
Verwenden der Ansteuerung über 1-10V DC:

Ergänzende Nutzungsinformationen: Gerätesteuerungsanschluss 5
4.1 Gebrauch der Steckverbindung
1. Wählen Sie eine geeignete Leitung mit min-
destens 2 Leitern entsprechend der Vorga-
ben in der Zeichnung.
2. Entfernen Sie die Isolierung am Leitungsen-
de entsprechend der Vorgaben in der
Zeichnung.
4. Anschließen eines potentialfreien Kontakts
oder einer 1–10V Ansteuerung
4.2 Belegung
HINWEIS: Verwendung des
Push-Lock-Anschlusses
Flexible Leiter ohne Aderendhülse oder Leiter
mit großem Querschnitt lassen sich mit Hilfe
der Hebel einfach anschließen. Dazu wird die
Klemmstelle durch den farbigen Hebel voll-
ständig geönet und verharrt in dieser geöne-
ten Position. Für den Leiteranschluss wird der
Hebel geschlossen. Starre Leiter und Leiter mit
Aderendhülse verdrahten Sie durch direktes
Stecken. Ein vorheriges Önen der Kontakt-
stelle ist nicht erforderlich. Zum Lösen eines
angeschlossenen Leiters wird der Hebel in die
Önungsposition gebracht und die Klemmstel-
le geönet. Der Leiter kann dann ohne
Kraftaufwand gezogen werden.
4.3 Verschließen der Steckverbindung
1. Verschließen Sie die Steckverbindung ent-
sprechend der Vorgaben in der Zeichnung.
2. Schließen Sie die Steuerleitung mit der
Steckverbindung am Gerätesteuerungsan-
schluss des Projektors an und xieren Sie
die Steckverbindung mit der Rändelmutter.
7
Ø 4 - 8 mm
0,14 - 0,75 mm²
AWG 26 - 18
24
0,4 Nm
15
1,5 Nm
15
15 0,4 Nm
4
1 2
5
3
blau
braun
–
+

6 Linde Warning Projector 85 pro
5. Aktivierung des Taktschwellers
5.1 Einsatz der Kabelbrücke
1. Entnehmen Sie den Anschlussblock aus
der mitgelieferten runden Steckverbindung,
Typ Phoenix Contact SACC-M12FS-5PL.
2. Setzen Sie die mitgelieferte Kabelbrücke
wie in der Abbildung dargestellt ein.
HINWEIS: Verwendung des
Push-Lock-Anschlusses
Flexible Leiter ohne Aderendhülse oder Leiter
mit großem Querschnitt lassen sich mit Hilfe
der Hebel einfach anschließen. Dazu wird die
Klemmstelle durch den farbigen Hebel voll-
ständig geönet und verharrt in dieser geöne-
ten Position. Für den Leiteranschluss wird der
Hebel geschlossen. Starre Leiter und Leiter mit
Aderendhülse verdrahten Sie durch direktes
Stecken. Ein vorheriges Önen der Kontakt-
stelle ist nicht erforderlich. Zum Lösen eines
angeschlossenen Leiters wird der Hebel in die
Önungsposition gebracht und die Klemmstel-
le geönet. Der Leiter kann dann ohne
Kraftaufwand gezogen werden.
5.2 Abschluss der Installation
1. Verschließen Sie den Anschlussblock mit
der mitgelieferten Schutzkappe.
2. Stecken Sie den Anschlussblock in den Ge-
rätesteuerungsanschluss des Projektor und
xieren Sie ihn mit der Rändelmutter.
3. Nach dem Einschalten des Projektors wird
die Projektion dauerhaft ein- und ausge-
blendet.
HINWEIS: Die Geschwindigkeit und die Inter-
valle des Taktschwellers sind vorgegeben und
können nicht verändert werden.
4
1 2
5
3
grau
braun

Supplementary usage information: device control connections 7
ENGLISH
Linde Warning Projector 85 pro
Supplementary usage information: device control connections
Contents
1. Intended Use ........................................................................................................................... 8
2. Technical Overview................................................................................................................. 8
3. Scope of Delivery.................................................................................................................... 8
4. Connecting a Potential-free Contact or a 1-10V Control.................................................... 9
4.1 Use of the Connector.........................................................................................................9
4.2 Assignment ........................................................................................................................9
4.3 Closing the Connector .......................................................................................................9
5. Activation of the Automatic Dimmer................................................................................... 10
5.1 Inserting the Cable Jumper..............................................................................................10
5.2 Completing the Installation ..............................................................................................10

8 Linde Warning Projector 85 pro
1
2
4
3
1. Intended Use
The device control connection is intended for
the following two applications:
1. Controlling the brightness of the projector,
including switching it on and o, via a po-
tential-free contact or 1-10V control. This al-
lows the projector to be controlled with an
external system.
2. Activation of the built-in automatic dimmer,
which allows the projection to fade in and
out continuously. Speed and intervals are
pre-set and cannot be changed.
ATTENTION! The projector may be damaged
if the control connector is used improperly..
Only connect the projector to suitable control-
lers and follow the instructions in the informa-
tion for use.
①Control via potential-free contact / 1-10V
②Activation of the automatic dimmer
③Control port
④Cold-device built-in plug
2. Technical Overview
3. Scope of Delivery
• Round connector, type Phoenix Contact
SACC-M12FS-5PL: for connecting a 1-10V
control cable to the Linde Warning Projector
85 pro.
• Cable jumper 40 mm with protective cap:
for activating the built-in automatic dimmer.
Control via potential-free contact:
closed = 0% | open = 100% brightness
Control via 1-10V DC:

Supplementary usage information: device control connections 9
4.1 Use of the Connector
1. Choose a suitable cable with at least 2 con-
ductors according to the specications in
the drawing.
2. Remove the insulation at the end of the
cable according to the specications in the
drawing.
4. Connecting a Potential-free Contact
or a 1-10V Control
4.2 Assignment
NOTE: Using the Push-Lock connection
Flexible conductors without ferrules or con-
ductors with large cross-sections can be easily
connected using the levers. The terminal point
is completely opened by the coloured lever and
remains in this open position. The conductor
connection is made by closing the lever. Wire
rigid conductors and conductors with ferrules
easily: through direct insertion. The contact
point does not have to be opened rst. To dis-
connect a connected conductor, the lever is
moved to the open position and the terminal
point is opened. The conductors can then be
removed with ease
4.3 Closing the Connector
1. Close the connector according to the spe-
cications in the drawing.
2. Connect the control cable with the con-
nector to the projector's control port and x
the connector with the knurled nut.
7
Ø 4 - 8 mm
0.14 - 0.75 mm²
AWG 26 - 18
24
0.4 Nm
15
1.5 Nm
15
15 0.4 Nm
4
1 2
5
3
blue
brown
–
+

10 Linde Warning Projector 85 pro
5. Activation of the Automatic Dimmer
5.1 Inserting the Cable Jumper
1. Remove the terminal block from the sup-
plied round connector, type Phoenix Con-
tact SACC-M12FS-5PL.
2. Insert the supplied cable jumper as shown
in the illustration.
NOTE: Using the Push-Lock connection
Flexible conductors without ferrules or con-
ductors with large cross-sections can be easily
connected using the levers. The terminal point
is completely opened by the coloured lever and
remains in this open position. The conductor
connection is made by closing the lever. Wire
rigid conductors and conductors with ferrules
easily: through direct insertion. The contact
point does not have to be opened rst. To dis-
connect a connected conductor, the lever is
moved to the open position and the terminal
point is opened. The conductors can then be
removed with ease.
5.2 Completing the Installation
1. Close the terminal block with the protective
cap supplied.
2. Insert the terminal block into the projector's
control port and secure it with the knurled
nut.
3. When the projector is switched on, the pro-
jection fades in and out continuously.
NOTE: The speed and intervals of the auto-
matic dimmer are pre-set and cannot be
changed.
4
1 2
5
3
grey
brown

Contact details
Manufacturer
Derksen Lichttechnik GmbH
Johannes-Rau-Allee 4
45889 Gelsenkirchen, Germany
Telephone: +49 (0) 209 98070-0
Fax: +49 (0) 209 98070-60
Email: [email protected]
Website: https://www.derksen.de/en/
Sales and service by:
Linde Material Handling GmbH
Carl-von-Linde-Platz
63743 Aschaenburg, Germany
Telephone: +49 (0) 6021 99-0
Fax: +49 (0) 6021 99-1570
Email: [email protected]
Website: http://www.linde-mh.de
Kontaktdaten
Hersteller
Derksen Lichttechnik GmbH
Johannes-Rau-Allee 4
45889 Gelsenkirchen, Germany
Telefon: +49 (0) 209 98070-0
Telefax: +49 (0) 209 98070-60
E-Mail: [email protected]
Website: https://www.derksen.de/
Vertrieb und Service über:
Linde Material Handling GmbH
Carl-von-Linde-Platz
63743 Aschaenburg, Germany
Telefon: +49 (0) 6021 99-0
Telefax: +49 (0) 6021 99-1570
Email: [email protected]
Website: http://www.linde-mh.de

Linde Material Handling GmbH
02/2023
Table of contents
Languages:
Popular Lighting Equipment manuals by other brands

Impos
Impos 30936728 manual

ML Accessories
ML Accessories T8BLED12 Installation & maintenance manual

EuroLite
EuroLite ACCU Bar-160 RGBA user manual

Saber Compact
Saber Compact ATD-80335 instruction manual

olympia electronics
olympia electronics GR-60 manual

Chauvet Professional
Chauvet Professional Ovation E-190WW Quick reference guide

Neoterics
Neoterics BLASTER 1000 instructions

Cameo
Cameo LED MINI PAR CAN user manual

ProLights
ProLights MOVING HEAD user manual

schmalenberger
schmalenberger fluvo luchs NT Spot Assembly manual

Light Mandalas
Light Mandalas Mandala Violet Shield user manual

Blizzard Lighting
Blizzard Lighting Tournado SKY W-DMX user manual