LinkAYL LK-CP7 Series User manual

LK‐CP7SERIESEXTERNALPOWERSUPPLYCONTROLPANEL
LK‐CP711/721S/731S/741SLK‐CP722/742SLK‐CP744
Feature
Consistsofamotherboardandamembraneswitch
Reset,Open/Stop/Close&channelselectionbuttonsandLEDindicators
Singlechannel,dualchannel,4channelorcascadecontrol
Built‐insynchronizerof2‐way,3‐way,4‐wayortwin2‐way
UnlimitedcascadecontrolcanbecascadedwithLK‐CP8,LK‐CP63controlpanel
andLK‐FP3,LK‐UFP2firecontrolpanelthatachievesanynumberofwindowsof
zonecontrolandgroupcontrol
CompatiblewithhandheldandwalltyperemoteLK‐RT11/LK‐RT12/LK‐WT21
CanhandleexternalinputsignalofManualSwitch,RemoteControl,Timer
Smoke/Gas/Wind&Rain/Temperature&HumiditySensors
Inchingmodeandcontinued‐runmodesettable
Withstrokememoryfunction
Externalpowersupply35W/72W/150W/300W
ModelList
ModelControlMethod
Input
Volt
(V)
Output
Volt
(V)
Freq
(MHz)
Temp
(℃)
Size
(mm)
LK‐CP7111waysingle
LK‐CP7222waysingle/group
LK‐CP721S2‐waysync
LK‐CP7444waysingle/group
LK‐CP731S3‐waysync
LK‐CP741S4‐waysync
LK‐CP742STwin2‐waysync
DC24
DC24
DC12
433.92
‐20
~
+65
160(L)
110(W)
40(H)
Application
ModelExternal
PowerLK‐SCE‐DLK‐LCD LK‐TC LK‐LLK‐L‐SLK‐L38A
600N/1KN
LK‐L38A
1500N
60W2Sets2Sets1Set 2Sets 2Sets 2Sets1Set
LK‐CP711
150W4Sets4Sets2Sets 4Sets 4Sets 4Sets2Sets
60W2Sets2Sets/2Sets 2Sets 2Sets/
150W4Sets4Sets2Sets 4Sets 4Sets 4Sets2Sets
LK‐CP722
300W8Sets8Sets4Sets 8Sets 8Sets 8Sets4Sets
60W2Sets2Sets/2Sets 2Sets 2Sets/
LK‐CP721S
150W//2Sets ///2Sets
LK‐CP744150W 4Sets4Sets/4Sets 4Sets 4Sets/
LK‐CP731S150W 3Sets3Sets/3Sets 3Sets 3Sets/
LK‐CP741S150W 4Sets4Sets/4Sets 4Sets 4Sets/
LK‐CP742S150W 4Sets4Sets/4Sets 4Sets 4Sets/

PanelDescription
LED/KEYColorStatusFunction
L1/K1BlueOn/OffACpowerindicator,Reset
L2/K2GreenOn/Off/FlashOpen
L3/K3RedOn/Off/FlashStop
L4/K4YellowOn/Off/FlashClose
L5/K5BlueOn/Off/FlashChannel1
L6/K6BlueOn/Off/FlashChannel2
L7/K7BlueOn/Off/FlashChannel3
L8/K8BlueOn/Off/FlashChannel4

WiringConnecting
TerminalSymbol DescriptionPriority Remark
V+DC24V+
DCInput
V‐ DC24‐
Externalpowersupplyinput
M1+M1Positive
M1‐ M1Negative
M2+M2Positive
M2‐ M2Negative
M3+M3Positive
M3‐ M3Negative
M4+M4Positive
Motor
M4‐ M4Negative
M+/M‐isalsocascadeoutput
connectingwithS+/S‐
24VDC24V+
12VDC12V+
DC
Output
GNDDCGND
MUManualOpen1
MSManualStop1
MDManualClose1
MGManualSwitchGND
S+CascadeOpen1
S‐ CascadeClose1
FSFireSignal2FireSignal,Smoke/GasSensor
WRDW/RSensorOpen3
TUTimerOpen4‐1
TDTimerClose4‐2
Input
Signal
T/HTemp/Humidity5MUSTbeblockedwithoutSensor

ControlMode
Controllerhasinchingmodeandcontinued‐runmodewhichisdefault
Inthecontinued‐runmode,presstheup/downkeylessthan1.5seconds,the
motorwillruncontinuously,presstheup/downkeymorethan1.5seconds,the
motorwillstopafterrunning160ms
Intheinchingmode,presstheup/downkeylessthan1.5seconds,themotor
willstopafterrunning160ms,presstheup/downkeymorethan1.5seconds,
themotorwillruncontinuously
Onlythemanualbuttonsonthepanel,manualswitch,remotecontroland
cascadesignalhaveinchingmode
KeeppressingbothofUPandSTOPbuttononthecontrollerfor5seconds,L2and
L3flash3timesandturnoffit’sinchingmodeforthecontroller,repeatthe
operationthecontrollerturnstocontinued‐runmode
Manualcontrol
AfterpoweronalltheLEDslightfor1secondandturnoff,thepowerindicator
lightL1normallyon
PressK1,alltheLEDslightfor1secondandturnoff,resetsuccessfully
L2willbeexplosion‐flashingaftercontrollerreceivesfiresignal
Externalmanualswitchisequivalenttocontrollerpanelswitch
Themaximumrunningtimeofthemotoris5minutes
Themotorup/downswitchingtimeis500ms
GroupControl
Bydefault,L1isnormallyon,therestLEDsareoffasgroupcontrolstatus
PressK2,L2turnson,thewindowsopen,L2turnsoffafter5seconds
PressK4,L4turnson,thewindowsclose,L4turnsoffafter5seconds
PressK3,L3turnson,themotorsstop,L3turnsoffafter1second
SingleChannelControl
PresschannelselectionkeysK5,K6,K7,orK8,thecorrespondingLEDlights,
channelselected
PressthechannelselectionbuttonagainornooperationonK2,K3orK4within
10seconds,LEDturnsoff,channelunselected
Intheprocessofopening/closingthecurrentwindow,youcanselectanother
channel(s)todrivethewindow
Remotecontrol
Thecontrollerencodesby433MHzlearningcode,canstore10setsof
transmissioncodes
Thecontrollerdefaultstomultiplechannel,singlechannelcontrollerhasthe
samewayasmultiplechannelone
MatchingCode
Powerthecontrolleron,choosethechannel(s)youwanttoset,canbesettoany
combinationofchannel1‐4
KeeppressingK3onthecontrollerfor5seconds,L3flashes3timesandturnsoff
Choosethechannelyouwanttosetontheremote,press[UP]within15seconds
LEDflashes3timesandturnsoff,codematchedsuccessfully
ClearingSingleCode
Powerthecontrolleron
KeeppressingK3onthecontrollerfor5seconds,L3flashes3timesandturnsoff
Press[DOWN]ontheremotewithin15seconds
LEDflashes3timesandturnsoff,codeclearedsuccessfully
ClearingAllCodes
Powerthecontrolleron,keeppressingK3&K4onthecontrollerfor5seconds
L3andL4flash3timesandturnoff
Allthecodeswillbedeletedafterthisoperation

SignalControl
Manualsignal.Controlthewindowbythebuttonsonitself,externaldrycontact
manualswitchandRFremote
Cascadedsignal.Asamastercontrollersendssignaltotheslavecontroller,can
alsobeusedasslavecontrollertoreceivethesignalfromthemastercontrollerto
drivethewindow
Firesignal.Capableofreceivingasignalfromfirecenter,smokesensor,gas
detectoropenthewindowautomatically
Wind/Rainsignal.Afterreceivingthesignalofwind/rainsensorclosethewindow
Temperature/humiditysignal.Controlthewindowbyprocessingexternal
temperature/humiditysensor
Timesignal.Controlthewindowbyworkingwithexternaltimer
SignalandPriority
SignalManualSignal FireSignalW/RSignal TimeSignal T/HSignal
Priority12345
Manualsignalincludesthesignalfrombuttonsonthecontroller,externaldry
contactmanualswitch,walltransmitter,handheldremote,wirelessW/Rsensor,
wirelesstimerandcascadedsignal
Firesignalincludesthesignalfromfirecentre,smokesensorandgasdetector
W/Rsignalincludesthesignalfromwiredwindandrainsensor,NOTincluding
wirelessW/Rsensor
TimesignalisonlythesignalfromWIREDtimer
T/Hsignalincludesthesignalfromtemperatureorhumiditysensor
ResetandShielding
Aftermanualsignalprocessedcontrollerresets&receivesinputsignalinreal
time
Afterprocessingthesignalfromfirecentre,smokesensororgasdetector,the
controllerimmediatelyshieldsalltheinputsignals,thecontrollermustbereset
bypressingK1manually.
AfterwiredW/Rsensorsignalprocessed,thecontrollershieldslowerpriority
signal,onlyreceivesthehigherprioritysignaluntilresetormanualsignal
processed
Afterwiredtimersignalprocessed,thecontrollershieldslowerprioritysignal,
onlyreceivesthehigherprioritysignaluntilresetormanualsignalprocessed
AfterT&Hsensorsignalprocessed,thecontrollerisintheresetstate
Optionswitchonthecontrolboardisforselectionofshieldingpriority3‐5signal
Option1‐3priorities3‐5respectively.Thesettingtakeseffectafterresetorrestart
SwitchOptionFunction
YWind/Rainsensorshielded
Option1
NNotshieldWind/Rainsensor
YT&Hsensorshielded
Option2
NNotshieldT&Hsensor
YTimershielded
Option3
NNotshieldTimer
CascadedControl
LK‐CP711/722/744canbeusedasamastercontroller,aslavecontrollerorplay
adualroleofmaster&slavecontrolleratthesametime.
LK‐CP721S/731S/741S/742Scanonlybeaslavecontroller
Asamastercontroller,connectstothemotorsorslavecontrollerstodrivethem
Asaslavecontroller,inputterminalsS+andS‐ areconnectedtotheoutput
terminalsM+andM‐ofthemastercontrollertoreceivetheinstructionstodrive
motors,ordrivethemotorsindependently
Playadualroleofmaster&slavecontroller,notonlycontrolledbyhigher‐level
controller,butalsodrivemotorsorlower‐levelcontrollersindependently
Nomattermaster,slaveorboth,itcanprocessalltheexternalsignalssuchas
manualswitch,remoteandsensors

Synchronouscontrol
Detectsthecurrentofeachmotorinrealtimeautomatically,onceoneormore
motorsinthegrouprunabnormally,allthemotorwillstoptoprotectthe
windows
Overloadcurrentandsynchronizationdelaycanbesetaccordingtoneed,protect
thewindowsandensurethatthewindowsarecompletelyclosed
LK‐CP721S
Supportsagroupoftwomotorsforsynchronization
Motorcurrentcanbesetfrom0.7Ato3A
Thesynchronizationdelaycanbesetfor0‐7seconds
LK‐CP731S/741S/LK‐CP742S
LK‐CP731Ssupportsagroupofthreemotorssynchronization
LK‐CP741Ssupportsagroupoffourmotorssynchronization
LK‐CP742Ssupportstwogroupsofmotorsynchronization,twomotorsinone
group,eachgroupofindependentcontrol,blockingcurrentandsynchronization
delaycanbesetseparately
Motorcurrent0.7/1.0/1.3/1.5A,synchronousdelay0/2/3/5seconds
StrokeMemory
Thecontrollercansetandmemorizetheopeningstroke.Uponthestrokeset,the
windowopeningsignalistriggeredonce,themotorwillrunthememorized
strokeonetime
Thedefaultmemorizedstrokerunsfor5minutes
Presstheupanddownkeysonthecontrollerfor3seconds,L2andL4flash3
timesandoff,successfullyenteredthestrokememorysettingstate
Inthestrokememorysettingstate,themanualkeysareforcedtothe
continued‐runmode,theremotecontrolkeysareforcedtotheinchingmode
Selectthechannel(S)tobeset,thedefaultisallselected,allthechannel
indicatorslight.Pressthechannelselectionkey(S),theindicatorslight,pressthe
channelselectionkey(S)againtheindicatorisoff,itisdeselected.Thesettingis
invalidwithoutoperationin15seconds
ON
123
ON
123
0.7A1.0A1.3A1.5A1.8A2.0A2.5A3.0A
ON
123
ON
123
ON
123
ON
123
ON
123
ON
123
Afterthechannelisselected,determinethestrokethatneedstobememorized
bypressingthemanualkeyortheremotecontrolkeybymovingorjogging
Thememorizedstrokecanbesettoonechanneloranycombinationofchannel,
upto4groups
ON
123
ON
123
0S1S2S3S4S5S6S7S
ON
123
ON
123
ON
123
ON
123
ON
123
ON
123
Afterthememorizedstrokesdetermined,turnonallthechannelindicatorsfor
settingthememorizedstroke.Presstheupanddownkeysonthecontrollerfor3
seconds,L2andL4flash5timesandoff,thememorizedstrokesofallchannels
setsuccessfullyandexitthestrokememorysettingstate,manualbuttonsand
remotecontrolbuttonsrestoredtotheoriginalmode
Instrokememorysettingstate,nooperationisperformedwithin15seconds,L2
andL4flash3timesslowlyandoff,thestrokememorysettingstateis
automaticallyexited,andthelastmemorizedstrokeisretained
Strokememorycanbesetrepeatedly.Thecontrolleronlyretainsthelast
successfulstrokevalueandautomaticallyclearsthepreviousone
Instrokememorysettingstate,pressupanddownbuttonsonthecontrollerfor3
secondsL2andL4flash3timesthememorizedstrokeisdeletedandrestoredto
thedefaultoutputfor5minutes

Strokememoryandsyncdelayfunctionarevalidonlyincontinued‐runoperation
Whenthememorizedstrokesofmastercontrollerandslavecontrollerarenot
thesame,theslavecontrollerwillrunitsownmemorizedstrokewhenitreceives
thecascadesignalfromthemastercontroller
Thememorizedstrokesetforeachchannelisretainedincasethecontrolleris
powereddownorreset
Whenclosingthewindow,theoutputtimeis5minutes,whichisindependentof
thememorizedstroke
OutputPower
Externalpowersupply35W/72W/150W/300Woptional
Thepowerofthecontrollerconnectedtothewindowopenermustmatchthe
ratedpowerofthecontrollerandcannotbeusedinexcesspower
Installationinstruction
Pleasereadthefollowinginstallationinstructionscarefullybeforeinstallingthis
product
Theinstallationofthisproductmustcomplywiththeeffectivelocalelectricity
specifications
Thecontrolsystemmustbeinstalledbytheprofessional
Themaximumoutputpowerofthecontrollercannotexceedtheratedtotal
power
Themainpowermustbecutoffbeforewiringtoensuresafeoperation
Donotusemetalobjectstotouchorcoverthecontroller,otherwiseitwillaffect
theremotecontrolsignalreception
Themaximumtransmissiondistanceofthewirelesssignalcanreach50metersor
moreintheopencondition
Thedistancebetweenthecontrollerandthegroundshouldbegreaterthan1.5
meters
Thedistancebetweenthecontrollerandtheceilingshouldbegreaterthan0.3
meters
Thedistancebetweenthecontrollerandthemotorshouldbegreaterthan1.5
meters
Avoidstaticinterferenceandpreventstaticdamagetoelectroniccomponents
Pleaseusethesoftwireandcable,afterinstallationensurethatthecablecarrier
isnotaffectedbythelongitudinaltension
Anexternalsensormustuseaproductthatiscompatiblewiththiscontroller
Cascadeuseofthecontroller,ifthemastercontrollerconnectedtoan
externalsensor(suchassmokesensor,windandrainsensor,etc.),
theslavecontrollerMUSTNOTuseinchingmode,incasethemaster
controllerreceivedthesmokesignaltoopenthewindow,theslave
controllerwillopenthewindowfor160msandstop
Ifthecontrollerisnotconnectedtoatemperatureandhumiditysensor,theT/H
portmustbeshielded(putoptionswitchoption3to“Y”position),otherwiseit
willaffectthecontrolofotherinputsignal
WhenusingLK‐CP721S/731S/741S/742S,alloutputportsmustbeconnectedto
themotors,otherwisethecontrollercannotworkproperly
Non‐professionalsisnotallowedtodisassemblethecontroller.Ifanyfunctionis
abnormal,pleasecontactyourlocaldealer
Troubleshooting
No. SymptomSolution
1LEDflashes,receivershutdown1.Checktheconnectionofwires
2.Checkthereceiversetting
2LEDonthetransmitterisofforweak
1.Makesuretherightinstallationof
thebattery.
2.Changethebattery
3Thetransmitterandthereceiver
workwell,themotordoesnotwork
1.Checkthewiringofmotor
2.Makesurethemotornofailure
This manual suits for next models
7
Table of contents
Popular Power Supply manuals by other brands

EVGA
EVGA 80 PLUS BRONZE BP Series manual

Electro Plastics
Electro Plastics EPI-LX-R Series quick start guide

Puls
Puls DIMENSION CP10.361 instruction manual

Assa Abloy
Assa Abloy ADAMS RITE PS-SE Owner's manual and installation instructions

Raycap
Raycap PowerPlus System 100-3-1U Series Installation instructions operations manual

BIO RAD
BIO RAD PowerPac HV Series instruction manual