SPECIFICATIONS
DuraComm®Corporation
6655 TROOST AVENUE
KANSAS CITY, MO. 64131
816-472-5544
www.duracomm.com
LP-18BC
User’s Guide
(These instructions are intended for use by a technician
familiar with electronic products)
Desk Top Power Supply
Features:
•-Extreme operating temp (-10 ~ +70℃)
•-Universal AC input (90~132/190~264VAC)
•-Built in Battery Backup/Charging Circuit/Low Voltage Disconnect
AC Input Voltage 115 or 230 VAC Switch selectable
DC Output Voltage Ch. 1= 13.8 VDC Ch. 2 = 13.6 VDC
Output Ripple 120 mV P-P @ full load
Rated Current (max.) 13.5 amps (15 amps - No Batt) 18A Int.=CH. 1
1.5 amps = CH. 2
Duty Cycle Continuous = 100% Industry Continuous
Comm. Service (CCS)
Overload 120~160% (CH. 1), 1.51~1.7A(CH. 2) rated output
Fold back, repower on to recover.
UPS mode: Protected by internal fuse
Over Voltage 15.87~18.63V max. Shut down- re-power on to
recover
Over Temperature 75℃(+-10℃) Shut down, Auto recover
Load Regulation 1.0% No load to full load
Line Regulation 0.5%
Inrush Current (max.) Cold Start 35A/230VAC
AC Current 4.6A/115VAC 2.6A/230VAC
Rated Power 250 Watts
Cooling Forced air, Fan on = 45℃
Working Temperature - 10 ~ 70℃
Efficiency 80 % typical
Safety UL 60950-1, 2nd:2011 UL/CUL recognized
Quality Assurance ISO 9001 standards
Dimensions 217 x 180 x 50 mm
Weight 3.5 lbs. / 1.6 Kgs.
WARNING: The individual user should take care to determine prior to use or installation
whether this device is suitable, adequate, or safe for the use intended. Since applications
are subject to great variation, DuraComm makes no representation or warranty as to the
merchantability, suitability, or fitness of these units for any specific application. Failures
require investigation as to the cause and/ or repair of the unit. THIS UNIT DOES NOT
HAVE ANY USER SERVICEABLE PARTS. SERVICE AND REPAIR MUST BE
REFERRED TO QUALIFIED PERSONNEL.
DESCRIPTION:The LP-18BC desktop power supply is UL & CUL recognized and
manufactured to ISO 9001 quality assurance standards. These power supplies convert AC
or DC input into low noise and ripple, regulated 13.8 volt DC output. The LP-18BC has
a built in battery back up and charging circuit with diode isolation for seamless transfer to
battery if input power is disrupted. Once input power is restored the LP-18BC will
automatically recharge the battery with 1.5 amps of trickle charging.
The LP-18BC contains a low voltage cutoff circuit which provides for low voltage
disconnect when the battery reaches 11.0 volts to prevent battery & load damage.
Note: Diagram reflects LP-18BC with Battery & Load
INSTALLATION
1. LOAD- Connect your 12 volt DC device using UL wiring to the LP-18BC
terminal output marked V (-) and V (+). Be certain to connect Positive (+) to
Positive (red) and Negative (-) to Negative (black).
2. BATTERY- Connect your 12 volt DC battery using UL wiring to the LP-18BC
terminal marked B (+) and B (-). Be certain to connect Positive (+) to Positive
(red) and Negative (-) to Negative (black).
Note: It is not recommended to connect 2 or more batteries as this will delay
charging time and if one battery fails it may cause other to malfunction.
OPERATION:Insert Power cord into an outlet of the proper voltage.
Press the ON/OFF (- / O) switch to the “ON” (-) position and observe if indicator
light on front of unit illuminates. If the indicator fails to light, re-check the
equipment installation.
LIMITED WARRANTY
DuraComm warrants to the initial end user, each power supply manufactured by DuraComm
to be free from defects in material and workmanship when in normal use and service for a
period of two years from the date of purchase from an authorized DuraComm dealer.
Should a product manufactured by DuraComm fail or malfunction due to manufacturing
defect, or faulty component, DuraComm, at its option, will repair or replace the faulty product
or parts thereof, which, after examination by DuraComm, prove to be defective or not
operational according to specifications in effect at the time of sale to the initial end user.
The product that is replaced or repaired under the provisions of this warranty will be
warranted for the remainder of the original warranty period, only, and will not extend into a
new two year warranty period.
The limited warranty does not extend to any DuraComm product which has been subject to
misuse, accidental damage, neglect, incorrect wiring not associated with manufacture,
improper charging voltages, or any product which has had the serial number removed,
altered, defaced, or changed in any way.
DuraComm reserves the right to change, alter, or improve the specifications of its products at
any time, and by so doing, incurs no obligation to install or retrofit any such changes or
improvements in or on products manufactured prior to inclusion of such changes.
DuraComm requires any product needing in or out of warranty service to be returned to
DuraComm. All requests for warranty service must be accompanied by proof of purchase,
such as bill of sale with purchase date identified. DuraComm is not responsible for any
expenses or payments incurred for the removal of the product from its place of use,
transportation or shipping expenses to the place of repair, or return expenses of a repaired or
replacement product to its place of use.
The implied warranties which the law imposes on the sale of this product are expressly
LIMITED, in duration, to the two (2) year time period specified herein. DuraComm will not be
liable for damages, consequential or otherwise, resulting from the use and operation of this
product, or from the breach of this LIMITED WARRANTY.
Some states do not allow limitations on the duration of the implied warranty or exclusions or
limitations of incidental or consequential damages, so said limitations or exclusions may not
apply to you. This warranty gives you specific legal rights which vary from state to state.
This warranty is given in lieu of all other warranties, whether expressed, implied, or by law.
All other warranties, including WITHOUT LIMITATION, warranties of merchantability and
fitness or suitability for a particular purpose, are specifically excluded. DuraComm reserves
the right to change or modify its warranty and service programs without prior notice.
NOTE: This device complies with part 15 of the FCC rules. Operation is subject to the
following 2 conditions; 1) This device may not cause harmful interference, and 2) This device
must accept any interference received, including interference that may cause undesired
operation.

Other DuraComm Power Supply manuals

DuraComm LPB-12M Specification sheet

DuraComm

DuraComm LPB-12M Specification sheet

DuraComm LPB-24 Specification sheet

DuraComm

DuraComm LPB-24 Specification sheet

DuraComm EH-30 User manual

DuraComm

DuraComm EH-30 User manual

DuraComm PSRM-5012NFPMU User manual

DuraComm

DuraComm PSRM-5012NFPMU User manual

DuraComm RU1-4012 User manual

DuraComm

DuraComm RU1-4012 User manual

DuraComm HE1U-5012-MU User manual

DuraComm

DuraComm HE1U-5012-MU User manual

DuraComm LP-14N User manual

DuraComm

DuraComm LP-14N User manual

DuraComm LP-14 User manual

DuraComm

DuraComm LP-14 User manual

DuraComm LPB-15 Specification sheet

DuraComm

DuraComm LPB-15 Specification sheet

DuraComm LP-10 User manual

DuraComm

DuraComm LP-10 User manual

DuraComm LPX Series User manual

DuraComm

DuraComm LPX Series User manual

DuraComm LPB-12H User manual

DuraComm

DuraComm LPB-12H User manual

DuraComm RLP-2024-BBSCLVD User manual

DuraComm

DuraComm RLP-2024-BBSCLVD User manual

DuraComm RM-10012 User manual

DuraComm

DuraComm RM-10012 User manual

DuraComm LPB-12 User manual

DuraComm

DuraComm LPB-12 User manual

DuraComm RLP-2024BBSCLVD-MU User manual

DuraComm

DuraComm RLP-2024BBSCLVD-MU User manual

DuraComm HE1U-2548 User manual

DuraComm

DuraComm HE1U-2548 User manual

DuraComm HE1U Series User manual

DuraComm

DuraComm HE1U Series User manual

DuraComm HE1U-1248-BBLVD User manual

DuraComm

DuraComm HE1U-1248-BBLVD User manual

DuraComm RMF-4012 User manual

DuraComm

DuraComm RMF-4012 User manual

Popular Power Supply manuals by other brands

Antec CP-850 user manual

Antec

Antec CP-850 user manual

TONGHER TH-Mars 2 Installation and user manual

TONGHER

TONGHER TH-Mars 2 Installation and user manual

Vertiv NetSure 2100 A31-S2 user manual

Vertiv

Vertiv NetSure 2100 A31-S2 user manual

Toshiba Power TS4 Specifications

Toshiba

Toshiba Power TS4 Specifications

ENERMAX PRO80PLUS datasheet

ENERMAX

ENERMAX PRO80PLUS datasheet

Bentel Security BXM24/25-U manual

Bentel Security

Bentel Security BXM24/25-U manual

Antelope Voltikus owner's manual

Antelope

Antelope Voltikus owner's manual

Seasonic ARCH Q5 Series installation guide

Seasonic

Seasonic ARCH Q5 Series installation guide

Teledyne T3PS13206 user manual

Teledyne

Teledyne T3PS13206 user manual

Thermal Dynamics CE CutMaster 50 instruction manual

Thermal Dynamics

Thermal Dynamics CE CutMaster 50 instruction manual

Pulsar HPSB 10A24D manual

Pulsar

Pulsar HPSB 10A24D manual

Allen-Bradley 1606-XLS240F Reference manual

Allen-Bradley

Allen-Bradley 1606-XLS240F Reference manual

Pulsar MSRK 2512 manual

Pulsar

Pulsar MSRK 2512 manual

Test Equipment Depot PS-1303C user manual

Test Equipment Depot

Test Equipment Depot PS-1303C user manual

ORTEC 4002D Operating and service manual

ORTEC

ORTEC 4002D Operating and service manual

Block BR 1000 instruction manual

Block

Block BR 1000 instruction manual

XFX XPS-750W-BES Brochure & specs

XFX

XFX XPS-750W-BES Brochure & specs

Eaton Power Xpert 9395 UPS Installation and operation manual

Eaton

Eaton Power Xpert 9395 UPS Installation and operation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.