LinMot S02-72/1000 User manual

NTI AG / LinMot Dok-Nr. 0185-0118-E_1V0_IG_Power_Supplies_S02_72_1000
Installation Guide Power Supply
ENG
Type S02-72/1000
Power range 1000 W

Installation Guide Power Supply ENG
Page 2 / 17 Type S02-72/1000 NTI AG / LinMot
Content
1General Information ................................................................................................................................. 3
1.1 Introduction........................................................................................................................................ 3
1.2 Explanation of Symbols..................................................................................................................... 3
1.3 Qualified Personnel ........................................................................................................................... 3
1.4 Liability............................................................................................................................................... 3
1.5 Copyright............................................................................................................................................ 3
2Safety Instructions ................................................................................................................................... 4
2.1 Personal Safety ................................................................................................................................. 4
2.2 Application as directed....................................................................................................................... 4
2.3 Transport, Storage............................................................................................................................. 4
2.4 Installation.......................................................................................................................................... 4
2.5 Electrical Connection......................................................................................................................... 5
2.6 Operation........................................................................................................................................... 5
2.7 Protection of Persons ........................................................................................................................ 5
3Mains Connection and Grounding.......................................................................................................... 6
4Description of the Connectors / Interfaces............................................................................................ 7
4.1 PE...................................................................................................................................................... 7
4.2 X30..................................................................................................................................................... 7
4.3 X56..................................................................................................................................................... 7
5LED Blink Codes....................................................................................................................................... 7
6Physical Dimension.................................................................................................................................. 8
7Output Voltage Regulation...................................................................................................................... 9
8Power Boost.............................................................................................................................................. 9
9Ordering Information.............................................................................................................................. 10
10 International Certificates................................................................................................................... 10
11 Declaration of Conformity and CE-marking.................................................................................... 16

Installation Guide Power Supply ENG
NTI AG / LinMot Type S02-72/1000 Page 3 / 17
1 General Information
1.1 Introduction
Observe the following safety instructions and the instructions on the unit (the term "unit" in the following
refers to a single power supply module) as well as all the information in this manual in order to prevent
danger to persons and hazards or damage to the unit and other connected products.
1.2 Explanation of Symbols
Triangular warning symbols warn against a danger.
Round command symbols tell what to do.
1.3 Qualified Personnel
All work such as transport, installation, commissioning and service is only allowed to be carried out by
qualified personnel. Qualified personnel in the sense of the safety instructions in this documentation are
persons who are familiar with the transport, installation, assembly, commissioning and operation of the
product and who have the appropriate qualifications.
This manual must be read carefully before transport, installation, commissioning, service and all safety-
related information must be adhered to.
1.4 Liability
NTI AG (as manufacturer of LinMot linear motors and MagSpring products) excludes all liability for damages
and expenses caused by incorrect use of the products. This also applies to false applications, which are
caused by NTI AG's own data and notes, for example in the course of sales, support or application activities.
It is the sole responsibility of the user to check the information and information provided by NTI AG regarding
their safety-relevant correctness. In addition, the entire responsibility for safety-related product functionality
lies exclusively with the user.Product warranties are void if products are used with stators, sliders, servo
drives or cables not manufactured by NTI AG unless such use was specifically approved by NTI AG.
or replacement as stated in our standard warranty policy as described
in our "terms and conditions" previously supplied to the purchaser of our equipment (please request copy of
same if not otherwise available). Further reference is made to our general terms and conditions.
1.5 Copyright
This work is protected by copyright.
Under the copyright laws, this publication may not be reproduced or transmitted in any form, electronic or
mechanical, including photocopying, recording, microfilm, storing in an information retrieval system, not even
for training purposes, or translating, in whole or in part, without the prior written consent of NTI AG.
LinMot® is a registered trademark of NTI AG.

Installation Guide Power Supply ENG
Page 4 / 17 Type S02-72/1000 NTI AG / LinMot
2 Safety Instructions
2.1 Personal Safety
For your personal safety
Disregarding the following safety measures can lead to severe injury to persons and
damage to material:
•Only use the product as directed.
•Never commission the product in the event of visible damage.
•Never commission the product before assembly has been completed.
•Do not carry out any technical changes on the product.
•Only use the accessories approved for the product.
•Only use original spare parts from LinMot.
•Observe all regulations for the prevention of accidents, directives and laws applicable on site.
•Transport, installation, commissioning and maintenance work must only be carried out by qualified
personnel.
oObserve IEC 364 and CENELEC HD 384 or DIN VDE 0100 and IEC report 664 or
DIN VDE 0110 and all national regulations for the prevention of accidents.
oAccording to the basic safety information, qualified, skilled personnel are persons
who are familiar with the assembly, installation, commissioning, and operation of the
product and who have the qualifications necessary for their occupation.
•Observe all specifications in this documentation.
o
specified product features.
oThe procedural notes and circuit details described in this documentation are only
proposals. It is up to the user to check whether they can be transferred to the
particular applications. NTI AG / LinMot does not accept any liability for the
suitability of the procedures and circuit proposals described.
•LinMot servo drives, power supplies and the accessory components can include live and moving parts
(depending on their type of protection) during operation. Surfaces can be hot.
o
installation or operation create the risk of severe injury to persons or damage to
material assets.
oFor more information, please see the documentation.
•High amounts of energy are produced in the power supply. Therefore, it is required to wear personal
protective equipment (body protection, headgear, eye protection, hand guard).
2.2 Application as directed
•LinMot power supplies are components, which are designed for installation in electrical systems or
machines. They are not to be used as domestic appliances, but only for industrial purposes according to
EN 61000
•When power supplies are installed into machines, commissioning (i.e. starting of the operation as
directed) is prohibited until it is proven that the machine complies with the regulations of the EC Directive
2006/42/EG (Machinery Directive); EN 60204 must be observed.
•Commissioning (i.e. starting of the operation as directed) is only allowed when there is compliance with
the EMC Directive (2014/30/EU).
•The technical data and supply conditions can be obtained from the nameplate and the documentation.
They must be strictly observed.
2.3 Transport, Storage
•Please observe the notes on transport, storage, and appropriate handling.
•Observe the climatic conditions according to the technical data.
2.4 Installation
•The power supply must be installed and cooled according to the instructions given in the corresponding
documentation.
•The ambient air must not exceed degree of pollution 2 according to EN IEC 61800-5-1.

Installation Guide Power Supply ENG
NTI AG / LinMot Type S02-72/1000 Page 5 / 17
•Ensure proper handling and avoid excessive mechanical stress. Do not bend any components and do
not change any insulation distances during transport or handling. Do not touch any electronic
components and contacts.
•Power supplies contain electrostatic sensitive devices, which can easily be damaged by inappropriate
handling. Do not damage or destroy any electrical components since this might endanger your health!
2.5 Electrical Connection
When working on live power supplies, observe the applicable national regulations for the
prevention of accidents.
The electrical installation must be carried out according to the appropriate regulations (e.g.
obtained from the documentation.
This product can cause high-frequency interferences in non-industrial environments, which
can require measures for interference suppression.
2.6 Operation
•If necessary, systems containing switching power supplies must be equipped with additional monitoring
and protective devices in accordance with the applicable safety regulations (e.g. law on technical
equipment, regulations for the prevention of accidents).
•After the power supply has been disconnected from the supply voltage, all live components and power
connections must not be touched immediately because capacitors can still be charged. Please observe
the corresponding stickers on the power supply. All protection covers and doors must be shut during
operation.
2.7 Protection of Persons
The power terminals L1, L2, L3 and PWR+, PGND remain energized for a maximum of five
minutes after the power supply has been disconnected.
Before servicing, disconnect supply, wait 5 minutes and measure between PWR+ and
PGND to be sure that the capacitors have discharged below 42 VDC.
The housing of the power supply can have an operating temperature of > 80 °C: Contact
with the heat sink results in burns.

Installation Guide Power Supply ENG
Page 6 / 17 Type S02-72/1000 NTI AG / LinMot
3 Mains Connection and Grounding
Figure 1: Mains connection, grounding and overvoltage category (OVC)
In order to assure a safe and error free operation, and to avoid severe damage to system
components, all system components must be well grounded to protective earth PE.
This includes both LinMot and all other control system components on the same ground
bus.
Each system component should be tied directly to the ground bus (star pattern). Daisy
chaining from component to component is forbidden.
Power supply connectors must not be connected or disconnected while DC voltage
is present. (Capacitors in the power supply may not fully discharge for several minutes
after input voltage has been disconnected). Failure to observe these precautions may result
in severe damage to electronic components in LinMot motors and/or drives.
Integral solid state short circuit protection does not provide branch circuit protection. Branch
circuit protection must be provided in accordance with the National Electrical Code /
Canadian Electrical Code, and any additional local codes.
Do not switch Power Supply DC Voltage. All power supply switching and E-Stop breaks
should be done to the AC supply voltage of the power supply. Failure to observe these
precautions may result in severe damage to the power supply unit.

Installation Guide Power Supply ENG
NTI AG / LinMot Type S02-72/1000 Page 7 / 17
4 Description of the Connectors / Interfaces
4.1 PE
PE
Protective Earth
1
PE
PE, Protective Earth
- Use min 4 mm2(AWG 11)
- Tightening Torque 2 Nm (18 lbin)
4.2 X30
X30
Supply Mains
2, 3, 4
1
L1, L2, L3
PE
3x400-480 VAC 50/60 Hz
PE, Protective Earth
- Tightening torque: 0.8 Nm (7 lbin)
- Use 60/75°C copper conductors only
- Conductor cross-section 2.5 - 4 mm2/ AWG 24 - 12
- Stripping length: 10 mm
- external circuit breaker (16 A Type C UL listed) required
- total conductor length must be 10 m or less
4.3 X56
X56
DC Output
4, 5
1, 2, 3
PWR+
PGND
Positive output
Negative output
- Tightening torque: 0.8 Nm (7 lbin)
- Use 60/75°C copper conductors only
- Conductor cross-section 2.5 - 4 mm2/ AWG 24 - 12
- Stripping length: 10 mm
- total conductor length must be 10 m or less
5 LED Blink Codes
LED Blink Codes
enabled
error
Description
On
Off
Power supply is enabled
Off / On
On
Error occurred

Installation Guide Power Supply ENG
Page 8 / 17 Type S02-72/1000 NTI AG / LinMot
6 Physical Dimension
in mm
Figure 2: Drawing of the power supply
S02-72/1000-xS Power Supplies
Width
mm
67
Height
mm
240
Height with fixings
mm
272
Depth
mm
193
Weight
kg
2.6
Mounting screws
Mounting distance
mm
up to M5
257 - 262
Case, degree of protection
IP
20
Storage temperature
°C
-
Transport temperature
°C
-
Operating temperature
°C
Relative humidity
< 95% (non-condensing)
Pollution
Pollution degree 2 acc. EN IEC 61800-5-1
Altitude
< 2000 m above sea level
Max. power dissipation
W
100
Mounting place
Control cabinet with minimum protection class IP54
Mounting position
vertical
Minimum distance between
surrounding components and air
admission and air exit holes
mm
50

Installation Guide Power Supply ENG
NTI AG / LinMot Type S02-72/1000 Page 9 / 17
7 Output Voltage Regulation
8 Power Boost
The power supply has a power boost functionality which provides up to 300% of the nominal load for up to 2
seconds.
After a power boost longer than 0.5 seconds, or if the total boost time in the last 4 seconds was longer than
0.5 seconds, the current is limited to the nominal current until a cooldown period has passed. The cooldown
period can be calculated with Figure 3. Below 0.5 seconds, no boost break is necessary.
Figure 3: Boost time versus required break time

Installation Guide Power Supply ENG
Page 10 / 17 Type S02-72/1000 NTI AG / LinMot
9 Ordering Information
Item
Description
Item-No.
S02-72/1000
Power Supply 72 V/1000 W, 3x400-480 VAC
0150-4535
10 International Certificates
Europe
See chapter Declaration of Conformity and CE-marking
IECEE
CB SCHEME
Ref. Certif. No. CH-11541
USA / Canada
All products marked with this symbol are tested and listed by Underwriters
Laboratories and the production facilities are checked quarterly by an UL
inspector. This mark is valid for the USA and Canada and eases certification
of your machines and systems in these areas.
File number E316095
UL 61800-5-1 Power Conversion Equipment
CSA C22.2 Industrial Control Equipment

Installation Guide Power Supply ENG
NTI AG / LinMot Type S02-72/1000 Page 11 / 17

Installation Guide Power Supply ENG
Page 12 / 17 Type S02-72/1000 NTI AG / LinMot

Installation Guide Power Supply ENG
NTI AG / LinMot Type S02-72/1000 Page 13 / 17

Installation Guide Power Supply ENG
Page 14 / 17 Type S02-72/1000 NTI AG / LinMot

Installation Guide Power Supply ENG
NTI AG / LinMot Type S02-72/1000 Page 15 / 17

Installation Guide Power Supply ENG
Page 16 / 17 Type S02-72/1000 NTI AG / LinMot
11 Declaration of Conformity and CE-marking
Wir
We
Nous NTI AG
Bodenaeckerstrasse 2
8957 Spreitenbach
erklären in alleiniger Verantwortung, dass das Produkt
declare under our sole responsibility that the product
déclarons sous notre seule responsabilité que le produit
Product
Item-No.
S02-72/1000
0150-4535
konform ist mit den Anforderungen der Richtlinien,
is conform to the provisions of directives,
est conformé aux exigences des directives,
Low Voltage Directive 2014/35/EU
EMC Directive 2014/30/EU
gestützt auf die folgenden Normen,
based on the following standards,
base aux normes suivants,
EN 61800-5-1: 2007
EN 61000-6-2: 2005 (Immunity for industrial environments)
EN 61000-6-4: 2007 (Emission for industrial environments)
Spreitenbach, 29.12.2021
Dr.-Ing. Ronald Rohner Dr.-Ing. Marco Hitz
CEO NTI AG RESPONSIBLE FOR DOCUMENTATION

© 2022 NTI AG / LinMot Subject to alterations
ALL LINEAR MOTION
FROM A SINGLE SOURCE
Europe / Asia Headquarters
NTI AG - LinMot & MagSpring
Bodenaeckerstrasse 2
CH-8957 Spreitenbach
Switzerland
Sales / Administration: +41 56 419 91 91
Tech. Support: +41 56 544 71 00
Web: https://www.linmot.com/
North / South America Headquarters
LinMot USA Inc.
N1922 State Road 120, Unit 1
Lake Geneva, WI 53147
USA
Sales / Administration: 262.743.2555
Tech. Support: 262.743.2555
Web: https://www.linmot-usa.com/
Visit https://linmot.com/contact/ to find a distributor near you.
Table of contents
Other LinMot Power Supply manuals