Lionel 180-Watt PowerHouse User manual

Lionel
180-Watt PowerHouse
Power Supply
Owner’s Manual
Lionel
180-Watt PowerHouse
Power Supply
Owner’s Manual
72-2983-250
10/06
CAUTION—ELECTRICALLY OPERATED PRODUCT
NOT RECOMMENDED FOR CHILDREN UNDER EIGHT YEARS OF AGE. AS WITH
ALL ELECTRIC PRODUCTS, PRECAUTIONS SHOULD BE OBSER ED DURING
HANDLING AND USE TO PRE ENT ELECTRIC SHOCK.
TRAN FORMER RATING —INPUT: 120 AC; 60 HZ ONLY.
AC OUTPUT: 18 ; 180 A

Congratulations on your purchase of the Lionel 180-Watt PowerHouse Power Supply! The
PowerHouse Power Supply generates a brawny 180 watts (ten amps) of alternating current.
Designed for use with the T CC Power aster, the Track Power Controllers, the modern ZW, or
the Direct Lockon, this power supply features an ON/OFF switch and a circuit breaker for safe
operation.
2
Congratulations!
Table of contents
Operating your PowerHouse Power Supply safely 3
Powering the T CC Power aster 4
Powering the Track Power Controller 4-6
Powering the ZW Transformer 7
Installing your T CC Direct Lockon 8-9
Resolving short circuits 10
Notes 11
Limited Warranty/Lionel Service 12
The following Lionel marks may be used throughout this instruction manual and are protected under law.
All rights reserved.
Lione ®, TrainMaster®, Odyssey®, Rai Sounds®, CrewTa k™, TowerCom™, DynaChuff™,
StationSounds™, Pu mor®, E ectroCoup er™, Magne-Traction®, CAB-1®Remote Contro er,
PowerMaster®, Lione ZW®, ZW®, PowerHouse®, TMCC®, Lione vi e™, Lockon®, Wire ess Tether™,
LionMaster®, FatBoy™, American F yer®, TrainSounds™, PowerMax™
The name FasTrack®is used with permission from Pitsco, Inc.

3
Operating your PowerHouse Power upply safely
When using electrical products, follow these basic safety precautions:
• Read these instructions thoroughly before using this device.
• The PowerHouse Power Supply is not recommended for children under eight years of age.
• Parents should periodically inspect the PowerHouse Power Supply for potential hazards and
have them repaired by an authorized Lionel Service Center. In the event that such a
condition exists, the PowerHouse Power Supply should not be used until it has been properly
repaired.
• The PowerHouse Power Supply is intended to be used indoors. Do not use the PowerHouse
Power Supply if water is present. Serious or fatal injuries may result.
• Do not use the PowerHouse for anything other than its intended purpose. This unit was
designed to operate with select Lionel controllers only.
• The PowerHouse Power Supply was designed to operate on 120-volt, 60-Hz power. Do not
connect the PowerHouse Power Supply to any other source of power.
• Do not operate the PowerHouse Power Supply with a damaged cord, plug, or case.
• To avoid the risk of electrical shock, do not disassemble the PowerHouse Power Supply.
There are no user-serviceable parts inside. If damaged, take the unit to an authorized Lionel
Service Center. A list of authorized Service Centers is included.
Do not operate your railroad unattended. Obstructed accessories or stalled trains
may overheat, resulting in damage to your layout.
• If the circuit breaker trips, turn the PowerHouse Power Supply OFF. Reset the circuit breaker,
then turn the power ON and resume operation. Resetting the circuit breaker during
operation may cause the train to surge forward.
• Unplug the PowerHouse Power Supply from the power source when not in use.
Warning!
Caution!

Powering the Track Power Controller
The PowerHouse Power Supply connections are made on the back panel of the Track Power
Controller (TPC) unit. These terminals are labeled HOT and NEUT under POWER IN. Your
PowerHouse Power Supply will power both the TPC unit and the track to which the TPC is
connected. Keep in mind that you may power the TPC unit with two PowerHouse Power
Supplies. Be sure to use two of the same type of PowerHouse Power Supplies (e.g., two 180-watt
units).
Powering the TMCC PowerMaster
As illustrated in Figure 1, connect the plug from the PowerHouse Power Supply to the
corresponding receptacle on the Power aster unit. Note that the plug and the receptacle
are keyed to fit only one way.
Plug in your PowerHouse Power Supply to a standard wall outlet and switch on the
PowerHouse Power Supply. The Power aster’s green power-on indicator illuminates to indicate
that it is receiving power. If the indicator does not illuminate, check the connection and be sure
that the PowerHouse Power Supply is plugged in. Refer to the Power aster Owner’s anual for
additional information.
Be sure to throw the Power aster’s power switch to 180 if the Power aster is
equipped with the switch.
4
Figure 1. Power aster connection
PowerMaster
receptable
PowerMaster Unit
PowerHouse
plug
Note!

5
Wiring the TPC unit with a sing e PowerHouse Power Supp y
To wire the TPC unit with a single PowerHouse, you will need to use the cables with
the two adapters from the T CC TPC Cable Set (available separately, 6-14194).
1. Plug the power output cable on the PowerHouse Power Supply into the adapter on the T CC
TPC Cable.
2. Attach the black wire to the HOT terminal on the TPC unit, located under the POWER IN
label.
3. Attach the white wire to the NEUT terminal on the TPC unit.
Powering your Track Power Controller (continued)
Figure 2. Powering your TPC with a single PowerHouse Power Supply
Note!
TPC
180-Watt PowerHouse
Power Supply
Hot
Neut
POWER IN
TRACKOUT
COMM
HOT
U
DATNEUT
A
COM
AUX+
AUX-

6
Wiring the TPC unit with two PowerHouse Power Supp ies
To wire the TPC unit with two PowerHouses, you will need to use the cable with two
adapters from the T CC TPC Cable Set (available separately, 6-14194).
1. Plug the power output cables on the PowerHouse Power Supplies into the adapters on the
T CC TPC Cable.
2. Attach the black wire to the HOT terminal on the TPC unit, located under the POWER IN
label.
3. Attach the white wire to the NEUT terminal on the TPC unit.
Wire similar PowerHouse Power Supplies only. Do not wire a 135-Watt PowerHouse
with a 180-Watt PowerHouse.
Powering your Track Power Controller (continued)
12
NEUT
HOT
TPC
180-Watt PowerHouse
Power Supplies
1
2
Figure 3. Powering your TPC with two PowerHouse Power Supplies
Note!
Note!
POWER IN
TRACK OUT
COMM
HOT
U
DATNEUT
A
COM
AUX+
AUX-

Powering the ZW Transformer
You may also use the PowerHouse Power Supply with your modern ZW Transformer. Remove
a jumper and connect the PowerHouse Power Supply as illustrated in Figure 4. Refer to the
ZW Transformer’s Owner’s anual for additional information.
7
COMMON
PROGRAM
U
A
U
B
U
C
U
D
Insert 180-Watt PowerHouse Power Supply connector
plug into ZW input jack.
Jumpers
Rear view of ZW Transformer
Figure 4. Powering the ZW Transformer with the PowerHouse Power Supply

8
Installing your TMCC Direct Lockon
The PowerHouse Power Supply and Command Base connections are found inside of the
structure. Follow these steps and refer to Figure 5 as you make these connections.
1. R mov th four scr ws from th bottom of th Lockon structur .
2. R mov th bas and lift th structur off of th circuit board.
3. Ins rt th Pow rHous plug into th r c ptacl on th circuit board.
4. Attach th Command Bas wir to th spring clip t rminal.
Press down on the top of the terminal clip so that a metal loop is formed. Slide the bare end
of the wire into the exposed loop. Release pressure on the terminal clip, allowing the
crimped metal to pinch the end of the wire in the metal loop. Give a little tug on the wire to
be sure that the hold is secure.
5. Us th switch to s l ct th typ of Pow rHous that you ar using.
Slide the switch to 180 for the 180-Watt PowerHouse.
6. Rout th Pow rHous cord and th Command Bas wir through th slot
as illustrat d in Figur 5 on pag 9.
7. R plac th structur and th bas , s curing th m with th four scr ws.
8. Conn ct th Dir ct Lockon to your track as d scrib d in th Own r’s
Manual.

9
180W
135W
Insert
PowerHouse
plug here
Lionel
Command Base
Lionel
PowerHouse
Figure 5. Direct Lockon connections and switch location
Connect Command Base
wire here
Installing your TMCC Direct Lockon (continued)

10
Resolving short circuits
Derailments, metal objects on the track, and improper wiring may cause a short circuit.
Short circuits will trip the circuit breaker on the PowerHouse Power Supply. If the circuit
breaker is tripped, turn off the PowerHouse Power Supply and then correct the short circuit.
After the short circuit has been corrected, press in the circuit breaker and turn on the
PowerHouse Power Supply.
Do not attempt to operate the PowerHouse Power Supply until the short circuit
has been removed.
Caution!

Notes
11

Limited Warranty/Lionel ervice
This Lionel product, including all mechanical and electrical components, moving parts, motors and
structural components, except for light bulbs, is warranted to the original consumer-purchaser, for on
y ar against original defects in materials or workmanship when purchased through an authorized Lionel
merchant.
This warranty does NOT cover normal wear and tear, light bulbs, defects appearing in the course of
commercial use, or damage resulting from abuse or misuse of the product by the purchaser. Transfer of this
product by the original consumer-purchaser to another person voids this warranty. odification of this product
voids this warranty.
Any warranted product which is defective in original materials or workmanship and is delivered by the
original consumer-purchaser to Lionel L.L.C. or an authorized Lionel L.L.C. Service Center, together with proof of
original purchase will, at the option of Lionel L.L.C., be repaired or replaced, without charge for parts or labor. In
the event the defective product cannot be repaired, and a replacement is not available, a refund of the original
purchase price will be granted. Any products on which warranty service is sought must be sent freight or postage
prepaid, as transportation and shipping charges are not covered by the warranty.
In no event shall Lionel L.L.C. be liable for incidental or consequential damages.
Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above
exclusion may not apply to you.
This limited warranty gives you specific legal rights, and you may have other rights which vary from state
to state.
Instructions for Obtaining ervice
If service for this Lionel L.L.C. product is required, bring the item, along with your dated sales receipt and
completed warranty information to the nearest Authorized Lionel Service Center. Your nearest Lionel Service
Center can be found by calling 1-800-4-Lionel, or by accessing our Website at www.lionel.com.
If you prefer to send your product back to Lionel L.L.C. for repair in ichigan, you must first call
586-949-4100 or FAX 586-949-5429, or write to Customer Service, P.O. Box 748, New Baltimore, I
48047-0748, stating what the item is, when it was purchased and what seems to be the problem. You will be sent
a return authorization letter and label to ensure your merchandise will be properly handled upon receipt.
Once you have received your return authorization and label, make sure that the item is packed to prevent
damage during shipping and handling. We suggest that you use the product’s original packaging. This
shipment must be prepaid and we recommend that it be insured.
Please make sure you have followed all of the above instructions carefully before returning any
merchandise for service. You may choose to have your product repaired by one of our Authorized Lionel Service
Centers after its warranty has expired. A reasonable service fee will be charged.
Warranty Information
Please complete the information below and keep it, along with your dated sales receipt. You must present
this and your dated sales receipt when requesting warranty service.
Name ________________________________________________________________________
Address ______________________________________________________________________
Place of Purchase ________________________________________________________________
Date of Purchase ________________________________________________________________
Product Number ________________________________________________________________
Product Description ______________________________________________________________
©2006 LIONEL L.L.C., CHESTERFIELD, I 48051-2493
UNITED STATES OF AERICA
PRINTED IN CHINA
Other manuals for 180-Watt PowerHouse
1
Table of contents
Other Lionel Power Supply manuals