Lite-Puter DP-PIR01 User manual

ISO 9001 CERTIFIED www.liteputer.com.tw
Lite-Puter
DP-PIR01 [EUM-A]
DP-PIR01
Wall-Mounted IR Human Body Sensor
【User Manual】
Lite-Puter Enterprise Co., Ltd.
Website:www.liteputer.com.tw
E-mail:sales@liteputer.com.tw

ISO 9001 CERTIFIED www.liteputer.com.tw
Lite-Puter
DP-PIR01 [EUM-A]
Index
CHAPTER 1 BEFORE INSTALLATION ............................................................................................................1
CHAPTER 2 INTRODUCTION.............................................................................................................................1
2-1 FUNCTION............................................................................................................................................................ 1
2-2 SPECIFICATION ....................................................................................................................................................1
2-3 DIMENSION.......................................................................................................................................................... 2
2-4ABOUT SENSOR ...................................................................................................................................................3
2-5 SYSTEM DIAGRAM...............................................................................................................................................4
CHAPTER 3 OPERATION ....................................................................................................................................5
3-1 ID SETTING.......................................................................................................................................................... 5
3-2 TIME READING/WRITING....................................................................................................................................6
3-3 ZONE READING/WRITING...................................................................................................................................6
3-4 MODE SELECT .....................................................................................................................................................6
3-5 BRIGHTNESS MODE SETTING.............................................................................................................................. 7
3-6 MODE SETTING ................................................................................................................................................... 8
LIMITED WARRANTY........................................................................................................................................... 11

ISO 9001 CERTIFIED www.liteputer.com.tw
Lite-Puter
DP-PIR01 [EUM-A]
1
Chapter 1 Before Installation
■ Ventilation environment is required,if in poor ventilation, thetemperaturein sensor
will be too high to be normally operated.
■ Can be continuously used in a year.
Chapter 2 Introduction
2-1 Function
1. Built-in IR sensing probe, sense the objection within 5m.
2. Sensing mode: brightness induction mode and occupancy sensor.
3. EDX-607 or other EDX control systems are compatible.
4. The zones should be the same when external device is used
5. Up to 255 sensors can work at the same time.
2-2 Specification
1.Protocol: EDX(RS-485)
2.Installation: wall mounted
3.Power: DC12V
4.Dimension: 60(W)* 104(H)* 42(D)mm
5.Weight: 75g

ISO 9001 CERTIFIED www.liteputer.com.tw
Lite-Puter
DP-PIR01 [EUM-A]
2
2-3 Dimension

ISO 9001 CERTIFIED www.liteputer.com.tw
Lite-Puter
DP-PIR01 [EUM-A]
3
2-4 About Sensor
2.4.1 Temperature range:-20℃~ +60℃
2.4.2 Detection angle and range:90℃
2.4.3 Detection range: 5m
2.4.4 Note for Using
2.4.4.1 When dust is adhesive to the lens, detection performance will be effected.
2.4.4.2 The lens is made of soft materials. After the load or shock is imposed on lens,
performance deterioration will happen.
2.4.4.3 It will be destroyed by imposing static electricity over +/-200V, thus, be avoid to
touch terminal etc. by hands during operation.
2.4.4.4 Do not clean the sensor by water, otherwise, the liquid poured into the lens will lead
to performance deterioration.
2.4.5 Precautions
DP-PIR01 is only required to be installed inside room, as the location and way of
installation matters the accuracy. The correct way of installation should be required as
below:
2.4.5.1 The sensor should be 2--2.2m far from the ground.
2.4.5.2 Far from the place where there is a temperature variation such as air-condition,
refrigerator and stove.
2.4.5.3 There should not be substances such as furniture, big-sized plant, glass and curtain
between DP-PIR01 and the detested person.
2.4.5.4 Forbidden to be directly facing the window, otherwise, false alarm will occur by heat
and persons outside.
In addition, degree of sensitivity to human body also matters direction of body movement.
The sensor is not sensitive to radial movement, but sensitive to transverse direction
movement (shown as below).
So, it is very important to install the sensor in an appropriate position to get the bestdetection.

ISO 9001 CERTIFIED www.liteputer.com.tw
Lite-Puter
DP-PIR01 [EUM-A]
4
2.4.6 Standard reference table of Lux
lux
Location
1500~5000
park, plaza;
750~1500
hotel reception desk, lobby;
300~750
conference room, office, classroom, restaurant and guest room
150~300
entertainment room, lavatory;
75~150
corridor/stairs, duty room, rest room, dressing room, illumination at
store
30~75
garage, warehouse
2-5 System diagram
……
Router
DP-104E
ID. 1
DP-PIR
01
ID. 2
DP-PIR
01
ID. 255
DP-PIR01
DP-PIR01 Graph
control
EDX BUS
EDX-607or other EDX
control systems

ISO 9001 CERTIFIED www.liteputer.com.tw
Lite-Puter
DP-PIR01 [EUM-A]
5
Chapter 3 Operation
3-1 ID Setting
When DP-PIR01 is in BUS, click Read ID list and left blanket will display all DP-PIR01
connected to the current BUS:
After reading ID NO. of all DP-PIR01, to select the desired ID (click ID NO. of ID list):
The current ID of upper right corner is displayed as below:
DP-PIR01(ID NO.=31) can be read or written.
ID setting of DP-PIR01:
Set ID NO. by DIP, and the detailed meaning of each DIP is as below:
ID NO. of DP-PIR01
connected to BUS
Rate of progress for reading ID list

ISO 9001 CERTIFIED www.liteputer.com.tw
Lite-Puter
DP-PIR01 [EUM-A]
6
DIP.1 and DIP.4 is ON as above, means ID NO. of DP-PIR01 is 9.
3-2 Time Reading/Writing
The date and time as shown is for PC, click Write to write time in DP-PIR01.
Click Read of upper left corner, then the current time will be displayed.
3-3 Zone Reading/Writing
Click Read to read the current zone:
Enter 3 to set zone of DP-PIR01 and click Write, and then click Read to show the digit
in input box (range of zone setting is 0-100).
3-4 Mode Select
There are two sensing modes.
Brightness induction mode: to operate by sensing the current brightness;
Occupancy sensor: to operate by infrared wave from human body.
To select occupancy sensor, choose Occupancy sensor and click Write:
To view the current mode, click Read.
Zone of DP-PIR01 is 1.

ISO 9001 CERTIFIED www.liteputer.com.tw
Lite-Puter
DP-PIR01 [EUM-A]
7
3-5 Brightness Mode Setting
Click Brightness mode setting and enter the screen
Click Write to set brightness interval value of respective zone;
click Read to view the setting value of each scene:
TickAuto, and the current brightness value will be probed automatically.
When the probed value is in different scene interval, the corresponding scene will be
recalled.

ISO 9001 CERTIFIED www.liteputer.com.tw
Lite-Puter
DP-PIR01 [EUM-A]
8
3-6 Mode Setting
Click Human Body Mode setting and enter the screen:
TickAUTO, and the current occupancy sensor status will be probed automatically.
3.6.1 Time/Brightness Mode Select
Click Read/Write to set time/brightness mode.
3.6.1.1 Time Mode Select
In time mode, when human body is sensed at the moment in the setting range,
DP-PIR01 will be activated. Enter the desired time range and click Write:
The above shows the human body is sensed only from 8:00 to 17:00, DP-PIR01 will
be activated.
Click Read to view the current time range.
3.6.1.2 Brightness Mode Select

ISO 9001 CERTIFIED www.liteputer.com.tw
Lite-Puter
DP-PIR01 [EUM-A]
9
In brightness mode, when human body is sensed at the brightness value in the
setting range, DP-PIR01 will be activated. Enter the desired brightness range and click
Write:
The above shows the human body is sensed only from 0 to 200, DP-PIR01 will be activated.
Click Read to view the current brightness range.
3.6.2 Occupancy Sensor Parameter
Enter the desired occupancy sensor parameter and click Write.
Sensitivity range is 0-100, the highest sensitivity is 100.
2.6.3 Scene/Channel Mode Select
In scene mode, the scene will be recalled when DP-PIR01 is activated.
In channel mode, the output value of the channel can be changed when
DP-PIR01 is activated.
2.6.3.1 Scene
The above shows SC1 will be recalled when human body is induced (DP-PIR01 is
activated), and SC2 will be recalled when human body is not induced (DP-PIR01
is not activated).
2.6.3.2 Channel

ISO 9001 CERTIFIED www.liteputer.com.tw
Lite-Puter
DP-PIR01 [EUM-A]
10
LEVEL value of each channel will be set as above when human body is induced
(DP-PIR01 is activated); any desired channel value can be written in, and then click
Read to read it.

ISO 9001 CERTIFIED www.liteputer.com.tw
Lite-Puter
DP-PIR01 [EUM-A]
11
Limited Warranty
1. Lite-Puter is only responsible for the product itself.
2. Lite-Puter guarantees to keep Lite-Puter’s from manufacturing defects
within a year since the distributing date.
3. Lite-Puter does not offer on-site service. If the defects appears
In Lite-Puter’s product, please deliver the product to local distributors or to Taipei
headquarters.
4. The warranty does not cover:
a. Any fault caused by false usage, imprudence (collision, inadequate installation or
adjustment, insufficient ventilation, or improper repairs)
b. Forcemajeure factors (flooding, earthquake, thunder, volcanic eruption, tsunami or other
factors beyond Lite-Puter control).
c. The cost of installing, reinstalling, adjusting, repairing, or reprogramming the product.
d. Other products or devices which are offered by Lite-Puter or not by Lite-Puter.
5. Lite-Puter does not warrant the product will operate without interruption or being free of
error.
Revision Record
Issued: 2012/07
Version
Record
A
First issued

ISO 9001 CERTIFIED www.liteputer.com.tw
Lite-Puter
DP-PIR01 [EUM-A]
12
World Headquarters:
Lite-Puter Enterprise Co., Ltd.
Address: 11F, No. 189, Gangqian Rd., Neihu Dist., Taipei City 11494, Taiwan.
Tel: +886-2-27998099
Fax: +886-2-27993828
Website: www.liteputer.com.tw
E-mail: sales@liteputer.com.tw
Shanghai Factory:
Lite-Puter Technology(Shanghai)Co.,Ltd.
Address: Building B5, No. 298, Lane 3509, Hongmei S. Road, Shanghai, China
Zip Code: 201108
Tel: +86-21-54408210
Fax: +86-21-54403376
Website: www.liteputer.com.tw
E-mail: sales_china@liteputer.com.tw
Table of contents
Popular Security System manuals by other brands

Federal Signal Corporation
Federal Signal Corporation 2-120 Description, Specifications, Installation, Operation, and Service Manual

Telstra
Telstra MX65W installation guide

olympia electronics
olympia electronics BS-413 manual

FingerTec
FingerTec TA100 DIY SERIES user guide

Bosch
Bosch D623 Series user guide

TeleAlarm
TeleAlarm Carephone 62 Quick programming guide