LK Systems LK Webserver User manual

1 (7)
Assembly instructions | LK Webserver
LK Webserver
Design
LK Webserver is used to access and control
LK Room Temperature Control ICS.2 and/or
LK Water Safety System WSS via the Internet or
a local network. The interface is suitable for cell
phones, tablets or computers and can be reached
via a website or an app for Android and Apple
IOS. Interface updates continually take place and
new functions will be available, see the latest
manual at www.lksystems.se/en.
LK Webserver continually logs the oor heating
system (temperatures, heat to/from etc.) to
enable optimization of the performance of the
oor heating systems. The logged data can be
retrieved and analyzed with LK Analyzer ICS.2
software which can be downloaded from the
LK Systems website.
Installation of the LK Webserver
The webserver can only be connected to the
LK Receiver 8 ICS.2 and LK Water Safety System
WSS. The webserver is placed near a room tem-
perature control if it is to be used for both oor
heating and water safety system. Otherwise it can
be located near a network socket and then com-
municate wirelessly with the master unit of the
water safety system.
The webserver can be installed in three differ-
ent ways:
1 Only for an LK Receiver 8 ICS.2, start the
installation at point 1 in the instructions below.
2 Using two webservers to create a wireless
bridge when an internet connection is not avail-
able near the receiver of the oor heating instal-
lation. Begin installation as shown below in
point 1 in the instructions.
3 Only for the LK Water Safety System WSS,
begin installation as shown below in point 11 in
the instructions.
1 Connecting the LK Receiver 8 ICS.2 with
LK Webserver
An example of a system with the webserver connected by cable
to the router. The webserver is connected to both the water safety
system and room temperature control ICS.2.
1. Attach the webserver with a suitable screw.
2. Switch off the power to the LK Receiver.
3. Connection is done with a three-conductor
cable (> 0.25 mm2). Connect the LK Receiver
8 ICS.2 (Master) three-pole busbar marked-
BUS with cable to the three-pole connection
of the LK Webserver marked BUS ICS.2.
Connect pole to pole, i.e. plus [+] is connect-
ed to plus [+], minus [-] to minus [-] and zero
[0] to zero [0].
BUS cable
4. Energize the LK Receiver.
5. Connect the cable from the mains adapter to
the input Power 5 V DC input on the web-
server, connect the mains adapter to a wall
socket.
6. Connect the network cable between the
webserver’s ethernet-connection and a
network socket with internet access.
EN.33.C.190.1709

2 (7)
Assembly instructions | LK Webserver
2 Connecting the communication bridge
via two webservers
It is possible to create a wireless communi-
cation bridge between the receiver of the
oor heating installation and a network
socket with internet access.
An example of a system with a webserver as a communication
bridge. The webserver is connected to both the water safety sys-
tem and room temperature control ICS.2.
7. Mount the other webserver near a network
socket.
8. Connect the cable from the mains adapter to
the input Power 5 V DC input on the web-
server, connect the mains adapter to a wall
socket.
9. Connect the network cable between the
webserver’s ethernet-connection and a net-
work socket with internet access.
10. On the webserver connected to the receiver,
press and release the red button. The LED
lamp will begin to blink.
Within three minutes, press and release the
red button on the webserver connected to a
network socket.
Thecommunication bridge settings are done
in the tab Network in the webserver’s user
interface, channel 6 is normally used.
3Connecting LK Master Unit WSS with
LK Webserver
11. The LK Master unit WSS communicates
wirelessly with the webserver connected to
the network socket with internet access.
12. Connect the cable from the mains adapter to
the input Power 5 V DC input on the web-
server, connect the mains adapter to a wall
socket.
13. Connect the network cable between the
webserver’s ethernet-connection and a net-
work socket with internet access.
14. Programming the webserver is carried out
by simultaneously pressing the Open and
Timer buttons on the Master Unit for 2
seconds (the radio symbol begins ashing).
After that press and release the red button
on the webserver (the right LED ashes
red). When the connection is established,
the right LED will show a red solid light for
a few seconds.
Web interface in the LK Webserver
1. Go to the homepage below on a computer
connected to the Internet or mobile device
https://my.lk.nu
If the webserver does not have internet ac-
cess, continue to point 9.
QR code for the login page.
2. Click on Register new user
Log in, new user
3. Fill in the email address, chosen password
and your name. Click on Register new user.
Register new user
EN.33.C.190.1709

3 (7)
Assembly instructions | LK Webserver
4. Check your email for a new message, or the
spam folder, activate your account by click-
ing on the link in the email from noreply@
lkics.net. Your browser will open a new
window.
5. Login with your email address and chosen
password given in step 3, click on Login.
Login
6. Connect your account with the webserver by
indicating the name of the webserver printed
on the label (ab1234) and password on the
label. Click on Connect your LK Webserver.
Your account
7. Information on room temperature control
is in the tab Thermo. and System. The water
safety system is in the tab Water. Possible
settings are in the tab Network. For a de-
scription of each tab, see the section user
interface.
There is also an app for the webserver that
can be downloaded from Google play and
the Apple Appstore. The app is called
LK AtHome
8. Reset the password on the login page.
Login, Reset password
The password can be reset with the Reset
password function. An email with instruc-
tions is sent to the registered email address.
9. If the webserver does not have internet ac-
cess, connect a computer using Windows to
your local network. Enter the address that is
printed on the webserver connected to the
router, see the image below. http://ab123,
then a dialogue box will appear for you to
enter the Username lk and Password that is
printed on the webserver.
Webserver label.
10. When the webpage is loaded, information is
shown for room temperature control in the
tab Thermo. and System. The water safety
system is in the tab Water. Possible settings
are in the tab Network. For a description of
each tab, see the section User interface.
EN.33.C.190.1709

4 (7)
Assembly instructions | LK Webserver
User interface, functions
LK Webserver makes a simpler and more trans-
parent user interface to adjust system settings
via the room thermostat’s menu and installation
parameters. The LK Webserver always begins
by searching for LK Room Temperature Control
ICS.2. If the webserver is only connected to the
LK Water Safety System, the tab Water can be
clicked on as no room temperature control is
found. The webserver is cloud-based and there
may be updates of the user interface and func-
tions that becomes directly available to the user,
see the latest manual at www.lksystems.se.
Menu
Log out from the account
Account
By clicking on the account icon, this allows a
change of name to the account and password on
the page below. Connect several webservers to the
account and remove a webserver from the account.
Account
Menu tab Thermo.
From the tab Thermo. this allows an overview of
the system’s receivers and connected room ther-
mostats.
2
4
5
10 9 8 7 6
3
3
1
Basic functions
1. Menu tabs.
2. Update button. The webpage is automatically
updated as soon as a change is made to the
webpage or every tenth minute.
3. Device name, preselected as Receiver 1, i.e.
Receiver 1. Click on the name Receiver 1 and
rename the unit to a chosen name, for exam-
ple after its location or the part of the system
that it serves. Max. 15 characters.
4. Any alarm symbol can be shown. A thermo-
stat can also be shown. Click on the icon to
get information about the alarm.
5. Gear icon, clickable, to return to thermostat
settings.
6. Reduce/increase the desired room temperature.
7. Display of the set room temperature.
8. Display of the room temperature. If two tem-
peratures are displayed, the left is the room
temperature / the right is the oor temperature.
9. Heating symbol. If the heating symbol is
on, this means that the room thermostat has
switched on the heating.
10. Room thermostat, preselected as Thermostat.
Click on the name Thermostat and rename the
thermostat to a custom name, for example its
location i.e. room name/room designation.
Max 15 characters.
EN.33.C.190.1709

5 (7)
Assembly instructions | LK Webserver
The desired room temperature can be set with
the round buttons or . Beside this displays
the measured/current room temperature. There
is a gear icon for each thermostat . Clicking on
the icon brings you to the menu system for that
specic room thermostat. All settings that can be
made from the physical room thermostat are eas-
ily made from here.
Menu page for settings of each room thermostat.
For each function, there is a clickable icon/infor-
mation icon . Summarized information is ob-
tained for the function. Additional information is
in the accompanying manual LK Room Tempera-
ture Control ICS.2.
Any alarm will be displayed as an icon in the
shape of a clock . The alarm icon is clickable.
Information about the current alarm will be dis-
played. For more information, see the accompa-
nying manual LK Room Temperature Control
ICS.2.
Menu tab System
Under the tab System, overall system func-
tions can be set, i.e. functions that affect all
room thermostats in the facility. An example
of a function is Holiday (vacation function). If
this is activated, all thermostats of the facil-
ity will lower the set room temperature. There
is a clickable icon/information icon for each
function. An important function Systemtab is
Set time and date, i.e. the system’s date and time
are set. This should always be done. Click on
the Setbutton and the system will synchro-
nize the time with your unit. For more in-
formation, see the accompanying manual
LK Room Temperature Control ICS.2.
Menu tab System
Menu tab Water
1 92 6 78
53 4
Menu tab Water
In the Water tab, the overall functions for the sys-
tem can be read and set.
1. Click on the text to change the name of the
unit. Max 15 characters.
2. Open for water.
3. Close for water.
4. Activate the timer function.
EN.33.C.190.1709

6 (7)
Assembly instructions | LK Webserver
5. Update button. The webpage is automati-
cally updated as soon as a change is made
to the webpage or every tenth minute.
6. A clickable gear icon to show more informa-
tion about the master unit.
7. A clickable gear icon to show more informa-
tion about the connected unit.
8. Any alarm symbol can be shown. This is
also shown for a control panel, leakage
detector or input link. Click on the icon to
get information about the alarm. During an
alarm, an email is sent to the address given
during registration and a push notice will
occur in the app.
9. Current temperature for the connected unit.
Master unit
The information is shown below when clicking
on the gear icon of the Master Unit. Only the
value for cold water is shown if the warm water
valve is not activated in the Master Unit.
• Timer value.
• Valve status for cold and warm water.
• Current pressure for cold and warm water.
• Status for external input.
• Adjust the temperature alarm value between
0 and -15°C (default +5°C).
• Value for the pressure alarm.
• Software version.
• Address of the unit.
• Values for DIP switches.
Menu tab Water, Master Unit expanded
Control panel & Input link are shown as
(Control panel)
When clicking on the gear for Control panel, the
information below is shown:
• Power supply: battery status, external or BUS
supply.
• Communication, wireless or wired.
• Communication quality.
• Address of the unit.
1. The clickable gear icon to display less informa-
tion about the unit.
2. Option to remove the unit from the Master
Unit.
12
Menu tab Water, Control panel expanded
Water detector
When clicking on the gear for a water detector,
the information below is shown:
• Power supply: battery status, external or BUS
supply.
• Communication, wireless or wired.
• Communication quality.
• DIP Switch values.
• Address of the unit.
1. Clickable gear icon to display less information
about the unit.
2. Option to remove the unit from the Master
Unit.
12
Menu tab Water, Water detector expanded
EN.33.C.190.1709

7 (7)
Assembly instructions | LK Webserver
LK Systems AB, Box 66, 161 26 Bromma, Sweden | www.lksystems.se
Menu tab Network
In the Network tab, there are settings and infor-
mation for:
• Network connection/webserver set-up for
a local network or Internet. Only access for
local login to the webserver.
• Communication bridge conguration.
• Status for wireless communication to
LK Master Unit WSS.
• Change the password for local login. Only
access for local login to the webserver.
• DHCP settings. Only access for local login to
the webserver.
• System info, software version and IP address.
Menu tab Network
Password
For local login it is possible to change the pass-
word from your default password to a chosen
password in the Network tab.
N.B., please consider using a strong password
containing a combination of lower-case and up-
per-case letters as well as numbers.
Reset the webserver
The webserver can be reset to factory settings.
During a reset, an assigned password may pos-
sibly be erased and the one printed on the label
will be active again. All names on the unit under
Thermotab and Watertab as well as all log data
will also be erased. The wireless connection to
the master unit of the Water Safety System will
be terminated.
The webserver is reset as follows:
• Remove the charger to the unit.
• Hold the red Reset/Mating button down.
• Reconnect the charger and continue to hold down
the red button.
• After 10 sec., release the red button.
Versions
From version: 3.1.850 in the permanent software
when cloud services are available. Older versions
can be updated, contact LK.
Generation 1 Generation 2
Cloud service
LK Systems intend to provide cloud service for
web login and apps for at least ve years after
LK Webserver is no longer in LK’s regular pro-
duct range. The product can be obtained with-
out cloud service via the external IP address
and port 8080 (e.g. http://123.456.789.123:8080).
The current IP address is shown in the Network tab.
Technical Data
RSK number 241 70 35
Product name LK Webserver
Power supply 230V AC / Mains adapter 5V DC <2 W
Working temperature -10 to +60°C 10-90% RH
Storage temperature -30 to +85°C 10-90% RH
Connection MODBUS RS485
Ethernet contact RJ45, 10Mbit
Radio 433 Mhz <10 mW
Channel separation 25 kHz, 69 channels
Modulation GFSK
Cable protection class IP20
Dimensions LxHxD 137 x 62 x 31 mm
EN.33.C.190.1709