Locstar LS-DT301 User manual

User Manual for
LOCSTAR Lift Controller
Applicable model: LS-DT301/311/503/513/-K01/-K02/-K12/-K13
Shenzhen Locstar Technology Co., Ltd.
Please read the manual when installation
Keep the manual properly for future reference.

电梯控制器用户手册 V2.0 V2.0 User Manual for Lift Controller
第2 页共8 页
Table of Contents
I. System Overview ..................................................................................................................3
II. System Composition.............................................................................................................3-4
III. Technical Parameters...............................................................................................................4
IV. Wiring Instruction for System Installation.......................................................................5
V. Lift Control Card-reader Setting............................................................................................6
VI. Explanation of Card Authority.................................................................................................6
VII. Working Procedure......................................................................................................................6

电梯控制器用户手册 V2.0 V2.0 User Manual for Lift Controller
第3 页共8 页
I. System Overview
The lift/elevator system security is an important part for a hotel. With Locstar system, all
lift-card holders shall be subject to prior authorization from the system administrator.
When using the lift, different person will be allocated with different authority, to enter into
floors.
Customers need to swipe their card through lift reader, and the lift will take the customers
to the assigned floor, if the customers are allowed to enter more than 1 floors, then press
the specified floor button.
II. System Composition
The system is composed of the lock software, lift controller, encoder, lift card reader and
cards.
1. Lock software is used for issuing cards. (And lift controller function should be selected
via the system setting).
2. Lift controller is the key component of the lift control system. Each lift controller can be
used to manage a 8 or 16 floors lift, maximum 64 floors lift.
3. Temic/Mifare encoder function: used for issuing cards with different authorities.
4. Lift card reader function: read card information.
III. Technical Parameters
1. LS-DT301/311 lift card reader( For Temic lock system)
Use T5557 card to read information .Which produced by ATMEL .
Fit Locstar Temic Door Lock System.
Reading distance: less than 10CM.
Data storage: long-term .
Frequency of repetition: long-term.
Information capacity: 264bit.
Password figure: 32bit
Voltage for reader: 12V
Working temperature: -10℃~55℃
Antistatic: >15000V

电梯控制器用户手册 V2.0 V2.0 User Manual for Lift Controller
第4 页共8 页
LS-DT503/513 lift card reader (For Mifare lock system)
Use Mifare S50 card to read information. Which produced
by PHILIPS. Fit Locstar Mifare Door lock System
or above is employed.
Reading distance: less than 5CM
Voltage for reader: 12V
Working temperature: -10℃~55℃
Antistatic: >15000V
2. LS-DTK01 lift controller
Working voltage: 24V
Working temperature: -10℃~55℃
Antistatic: >15000V
Floors to be controlled: 1-16 floors
LS-DTK02 lift controller
Working voltage: 24V
Working temperature: -10℃~55℃
Antistatic: >15000V
Floors to be controlled: 1-16 floors
LS-DTK12 lift controller
Working voltage: 24V
Working temperature: -10℃~55℃
Antistatic: >15000V
Floors to be controlled: Floor 1-8
LS-DTK13 lift controller
Working voltage: 24V
Working temperature: -10℃~55℃
Antistatic: >15000V
Floors to be controlled: Floor 2-9

电梯控制器用户手册 V2.0 V2.0 User Manual for Lift Controller
第5 页共8 页
IV. Wiring diagram instruction
1. Installation
To facilitate wiring, the lift controller should be positioned near to the lift
control cabinet at the top of lift. Lift control reader, which is mounted
on the car,.Lift reader power supply is powered by the lift controller.
2. Wire requirement:
Lift card reader and lift controller: RVVP128 (4*0.5);
Lift button and lift controller: RVV (2*0.5) (button on the first floor);
24V power for lift controller: RVV (2*0.5)
12V power for lift reader: RVV (2*0.5)
3. After converting 110-240V to 24V/12V, allow the power supply connected to the main
board of lift controller.
4.Wiring diagram for lift controller and lift: Connect the wires of lift floor buttons to the
corresponding binding posts on the main board .(The floor number on floor button should
be consistent with that on the lift controller).
5. Wiring diagram for lift card reader and lift controller: Connect lift controller to lift Reader
according to the Wiring Diagram, the card reader will be constantly illuminated after
power-on.

电梯控制器用户手册 V2.0 V2.0 User Manual for Lift Controller
第6 页共8 页
Wiring Diagram of Lift Controller and lift
Remark:for the above lift control and lift wiring diagram,each PCB controls 4 floors.

电梯控制器用户手册 V2.0 V2.0 User Manual for Lift Controller
第7 页共8 页
V. Lift Reader Setting
1.How to setup Lift Reader
Temic system:
Step 1:Touch the existed authorization card to reader, blue indicator light will flash one
time;
Step 2:Touch room setup card to lift reader, the blue indicator light will flash one time;
Mifare system:
Step 1:Touch the existed authorization card to reader, blue indicator light will flash one
time;
Step 2:Touch room setup card to lift reader, the blue indicator light will flash one time;
Step 3:Touch clock card to the reader, the blue indicator light will flash one time.
2. How to Clear Lift Reader (2 options)
A. Directly touch the Cancel Authorization Card, after one short sound and flash of blue
light, the authorization is cleared;
B. Forced clearing: open the outer cover of lift card-reader, press the reset switch within
10 seconds and touch Authorization card to the reader. After a long sound, authorization
is cleared.
VI. Explanation of Card Authority
1. Scope of lift to be controlled with building control mode :
(Card can open for all floors)
Master card, building card, cleaning card, emergency card, foreman card (MF system only),
floor card, guest card: available for all floors.
2. Scope of lift to be controlled with floor control mode :
(Card can open for assigned floors)
1) Master card, building card, cleaning card, emergency card, foreman card (MF system
only), floor card: available for all floors.
2) Guest card: the floor to which the card corresponds.

电梯控制器用户手册 V2.0 V2.0 User Manual for Lift Controller
第8 页共8 页
VII. Working Procedure
1. Working procedure for building control mode:
1) After entering the lift, swipe guest card then press the proper button of floor. For
example, a guest holds a guest card, after swiping card, can press any
floor buttons for enter into;
Remark: After the guest swipes the card, the lift controller will activate all building
Output relays, and then short circuit signal is output to the lift controller.
If guest doesn’t press any button within 5s, the relay will automatically disconnect 5s later.
2. Working procedure for floor control mode:
1) After entering the lift, swipe the card then press the proper button of floor. For
example, a guest holds a 7th floor guest card, after swiping card in the lift, need to press
7th floor button.
Remark: After the guest swipes the card, the lift controller will activate the output relay
that corresponds to the 7th floor, and then short circuit signal is output to the lift controller.
After receiving the signal, lift controller activates the 7th floor button (other floor buttons
are under resting state); If guest doesn’t press button within 5s, the relay will
automatically disconnect 5s later.
This manual suits for next models
7
Table of contents