Caution!
This unit will heat up under certain operating conditions. Do not obstruct the inlet to the
cooling fan or the exhaust vents. Also, do not obstruct the fan inlets on the CureJetTM or its
exhaust. The unit has an internal mechanism that shuts it off if a preset internal temperature is
reached during operation.
1.4 Field of Application, (Intended Usage)
The Loctite®CureJetTM LED System is designed for use with light cure products that cure
when exposed to ultraviolet and/or visible light. The system can be operated manually,
operated with the integrated timer, or controlled with an external switch. The system is
designed for intermittent or constant duty cycle.
2. Description
2.1 Theory of Operation
1364033 Single CureJetTM Controller will operate all existing CureJetTM Light Sources and
all new CureJetTM Light Sources. LED Controller 976419 will only operate 976420 (405)
LED Light Sources, and 976418 (IndigoTM ) LED Light Sources.
The Loctite® CureJetTM LED System utilizes a focused LED light source (The CureJetTM) and
the LED Controller. The unit is powered by the AC line cord, 985470. When the unit is
switched on, the proper electrical power is supplied to the LED resulting in immediate full
power. Curing will take place when the light is directed at the liquid adhesive. The time
required to complete the curing process depends primarily on the offset distance from the end
of the light source to the surface of the adhesive and the type of adhesive being used.
The exposure time can be controlled in either the manual mode, the use of the integrated
control timer, or an external switch.
The unit has an internal mechanism that shuts it off if the preset internal temperature is reached
in the Controller or the CureJetTM during operation. Should this occur, the unit would not
operate until the unit has cooled below this thermal limit.
The Loctite®CureJetTM LED Light Source can also be actuated by a remote foot switch, P/N
97201.
2.2 Operating Elements and Connections, refers to Figure 1
1. Manual Mode/Time Mode Switch
This switch changes the mode between timed (via the control timer setting) and manual
control.
2. Start Button
Depressing the Start Button turns on the light. In Manual Mode, light will stay on until the
button is released. In Timed Mode, the light will stay on until the control timer counts
down to 0s.