Product User Guide | 3
Bridge101A
PRODUCT USER GUIDE
Set Password
LED Indicators
Recalibration
Trigger Settings
Multiple Start/Stop Mode Activation
To password protect the device so that others cannot
start, stop or reset the device;
1. In the Connected Devices panel, click the device
desired.
2. On the Device Tab, in the Information Group, click
Properties. Or, right-click the device and select
Properties in the context menu.
3. On the General Tab, click Set Password.
4. Enter and confirm the password in the box that
appears, then select OK.
Status: Green LED blinks every 5
seconds to indicate the device is logging.
Alarm: Red LED blinks every 1 second to
indicate an alarm condition is set.
To change the settings for the alarm:
1. Select Alarm Settings from the Device Menu in the
MadgeTech Software. A window will appear allowing to
set the high and low alarms and warning alarms.
2. Press Change to edit the values.
3. Check Enable Alarm Settings to enable the feature
and check each high and low, warn and alarm box
to activate it. The values can be entered in the field
manually or by using the scroll bars.
4. Click Save to save the changes. To clear an active alarm
or warn, press the Clear Alarm or Clear Warn button.
5. To set an alarm delay, enter the duration of time into
the Alarm Delay box in which the readings can be
outside of the alarm parameters.
Materials: Small Phillips Head Screwdriver and a
Replacement Battery (LTC-7PN)
1. Puncture the center of the back label with the screw
driver and unscrew the enclosure.
2. Remove the battery by pulling it perpendicular to the
circuit board.
3. Insert the new battery into the terminals and verify it
is secure.
4. Screw the enclosure back together securely.
• To start device: Press and hold the pushbutton for 5
seconds, the green LED will flash during this time. The
device has started logging.
• To stop the device: Press and hold the pushbutton for
5 seconds, the red LED will flash during this time. The
device has stopped logging.
Recalibration is recommended annually. To send
devices back for calibration, visit madgetech.com.
The device can be programmed to only record based off
user configured trigger settings.
1. In the Connected Devices panel, click the device desired.
2. On the Device Tab, in the Information Group, click
Properties. Or, right-click the device and select
Properties in the context menu.
3. Select Trigger in the Properties window.
4. Trigger formats are available in Window or Two Point
Mode. Window mode allows a high and/or low trigger set
point, and a trigger sample count or “window” of time
recorded when set points are exceeded to be defined. Two
point allows for different Start and Stop setpoints to be
defined for both the high and low triggers.
Refer to the Trigger Settings - MadgeTech 4 Data Logger
Software video on madgetech.com for instructions on
how to configure Trigger Settings.
Device Operation (cont’d)
Alarm Settings
Device Maintenance
Battery Replacement
Note:Besurenottoovertightenthescrewsorstripthethreads.