Logicbus RADIONODE RN400-T2PM User manual

User Manual
PM 2.5 Particulate
Matter Data Logger
RN400-T2PM
2021 | Rev. 1.02 Keep this document nearby so that it may be referred to when needed.

02
Order List
About this Manual Introduction Installation Operation Configuration Radionode365 Maintenance Customer Service
Information
HTTP Radionode
Protocol V2
CONTENTS
Operation
Installation
Introduction
Configuration
About this Manual
08
04
14
19
05
Key Features
Exterior
Accessories
Specifications
Terminal Block
Data Logger Installation
Connecting Terminal Block
Intellectual Property Rights
Notational Conventions
Viewing Channel Information
Viewing Device Information
Resetting Data Logger
Memory Card for Data Logging
Device Information
Server
Measurement
Wi-Fi Network
Display
Commands
Memory Card Usage Configuration
04
04
09
10
12
06
06
07
07
15
16
17
18
21
22
23
24
27
28
29

03
Order List
About this Manual Introduction Installation Operation Configuration Radionode365 Maintenance Customer Service
Information
HTTP Radionode
Protocol V2
Check-in
Data-in
Data Logger
Accessories
Cleaning
Batteries
Firmware Update
Manufacturer Contact Information
Warranty
Limit of Liability
Certifications
Adding Devices from Your Smartphone
Adding Devices from Your Computer
Checking Communication With Radionode365 Server
RS-485 Modbus Communication
30
30
38
38
39
46
46
32
35
42
45
40
40
40
41
Order List
Maintenance
Radionode365
HTTP Radionode Protocol V2
Customer Service Information 40
38
46
42
31

04
Order List
About this Manual Introduction Installation Operation Configuration Radionode365 Maintenance Customer Service
Information
HTTP Radionode
Protocol V2
About
this
Manual
©2021DEKISTCo.,Ltd.
AllcontentsandfigureshereinarepropertyofDEKISTCo.,Ltd.
Reproductionorredistributionofallorpartofthisdocumentinany
wayisnotpermittedwithoutpriorconsentfromDEKIST.
Thisdocumentcontainsinstructionsforusageandinstallationof
the RADIONODE® RN400-T2PM. Product specifications and
certain features herein may be subject to change without prior
notice.Figuresusedinthismanualareforexplanatorypurposes
only,and may differ from your system depending on installation
conditions. Software screenshots may change after software
updates.
Notational
Conventions
Intellectual
Property
Rights
Additionalhelpfulinformationismarkedwith"Note".
Failuretofollowinstructionsmarkedwith"Warning"may
resultinslightinjurytotheuser.
Failuretofollowinstructionsmarkedwith"Caution"may
resultinequipmentdamageormalfunction.

05
Order List
About this Manual Introduction Installation Operation Configuration Radionode365 Maintenance Customer Service
Information
HTTP Radionode
Protocol V2
Introduction
The RN400-T2PM Data Logge r p er io di ca ll y m ea su re s the
concentration of PM 2.5 partic u l ate matter (also known
as fine dust) in the atmosphere b y s ize and sends
measurement data to the Radion o d e 365 server. RN400-
T2PMcomeswithatotalof s ixI/Ochannels.
Theunitofmeasurementisμg/m³.IfChannel1measurementis
42.75, then particles 0.3 2.5 μm in size in the space of 1
meter³weigh42.75micrograms.
ThePMsizeisacumulativerange.AsasizeofPM10includesthat
of
PM2.5,themeasurementofChannel2isalwaysequaltoor
greater
thanthemeasurementofChannel1.UsetheUACalibratorprogram
toswitchthePMsizefromaccumulativerangetosegmentrange.
FormoreinformationontheUACalibrator,seeRS-485Modbus
Communicationonpage30.
IfChannel6measurementis127,thenthenumberofparticles
biggestinsizeamongotherparticlesinthespaceof1meter³is127.
OnlymeasurementsofChannels1,2and6aredisplayedasdata
intheDataLogger.UseRadionode365toseemeasurementsofall
channels.
Channel1
Channel2
Channel3
Channel4
Channel5
Channel6
AccumulativeRange SegmentRange
0.3μm≤PM2.5≤2.5μm
0.3μm≤PM10≤10μm
0.3μm≤PM0.5≤0.5μm
0.3μm≤PM1.0≤1.0μm
0.3μm≤PM4.0≤4.0μm
Numberofparticleslargest
insize
1.0μm<PM2.5≤2.5μm
4.0μm<PM10≤10μm
0.3μm<PM0.5≤0.5μm
0.5μm<PM1.0≤1.0μm
2.5μm<PM4.0≤4.0μm

06
Order List
About this Manual Introduction Installation Operation Configuration Radionode365 Maintenance Customer Service
Information
HTTP Radionode
Protocol V2
Exterior
Key Features KeyfeaturesoftheRN400-T2PMinclude:
UseWi-FiconnectiontoeasilyconfigureyourDataLogger.
MeasurementdatacanbeviewedremotelyfromRadionode365
website.SeeRadionode365onpage31.
MeasurementdatacanbeloggedonamicroSDcard.
ModbusRTU(RS-485)communicationallowsPLCtoaccessData
Logger.
❶ Display ❷ Menu button ❸ Display button ❹ Power
button❺Cablegland
PowercablesandPLCorotherdevicecablesareconnectedviacable
glandstotheinternalterminalblock.
Forinstructionsonhowtousethebuttons,seeOperationonpage
14.
SW
POWER
ON/OFF
●
●
●
●
S W POWER
ON/OF F
2
3
1
5
4

07
Order List
About this Manual Introduction Installation Operation Configuration Radionode365 Maintenance Customer Service
Information
HTTP Radionode
Protocol V2
Accessories
Specifications
3.6VBattery DCAdapter(12V,500mA)
Intheeventofpowerfailure,aC-type3.6Vbatterymustbeplaced
in the Data Logger. RADIONODE Data Logger is designed to not
operatewithoutabattery,evenwhenexternalpowerisconnected.
SWPOWER
ON/OFF
165 mm
50 mm
100 mm
115 mm
Wi-Fi
RS485
CableGland
WaterResistance
Rating
ExternalDCPower
Size
OperatingConditions
2.4 GHz IEEE 802.11 b/g/n, WPA2-
EnterpriseModbusRTU
PG-9
IP65
5∼30V(BuiltinUPS)
165×50×115mm
-10~60°C,0~95%RH(non-condensed)

08
Order List
About this Manual Introduction Installation Operation Configuration Radionode365 Maintenance Customer Service
Information
HTTP Radionode
Protocol V2
Installation
Thefollowingprocedurewillguidefromtheinstallationprocedureto
theRadionode365registrationprocess.
1.Installsensorsorconnectotherdevices
totheDataLoggeras
needed.
2.Connectpowerandinsertthebattery.
3.UsethevirtualWi-Firouterfeatureto
configuretheDataLogger.
SeeConfigurationonpage19.
4.NowthattheDataLoggerhasbeen
installed,itmustberegistered
toRadionode365.SeeRadionode365onpage31.
Dependingonyourinstallationcircumstancesandconditions,your
installationprocessmayvary.Forexample,ifyouareinstalling
multipleDataLoggers,youmightfinditeasierto:
InsertbatteriesintoallDataLoggersbeforerunning.
ConfigureoneDataLoggerfirst.
UseamicroSDcardtosetupadditionalDataLoggers.Forthis
method,seeMemoryCardUsageConfigurationonpage29.
RegistertheDataLoggersontoRadionode365.
Finally,installtheDataLoggers.
1.
2.
3.
4.
5.

09
Order List
About this Manual Introduction Installation Operation Configuration Radionode365 Maintenance Customer Service
Information
HTTP Radionode
Protocol V2
Terminal
Block
Micro SD Card
Slot Fine Dust
Sensor
MicroUSBPort
TempSensor
Terminal
BatteryHolder
PowerOutlet
TerminalBlockscanbefoundinsideofaDataLogger,withother
componentsarrangedasfollows:
MicroSDcardisusedtologmeasurementdata.seeMemoryCard
forDataLoggingonpage18.
ThemicroUSBportisusedforsensorcalibration.AsRN400Series
sensorsareshippedaftercalibration,nofurthercalibrationis
required.However,ifthesensormalfunctions,contactDEKISTfor
inspection.
Formoreinformationontheterminalblock,seeConnecting
TerminalBlockonpage12.
1 2
4
3
5
6
❶
❹
❷
❺
❸
❻

10
Order List
About this Manual Introduction Installation Operation Configuration Radionode365 Maintenance Customer Service
Information
HTTP Radionode
Protocol V2
Data Logger
Installation
Loosenthecablegland.
ThegeneralprocedureforinstallingaDataLoggerisasfollows:
Routethecablesofthedevicethatwillbeconnectedthroughthe
glandandconnecttotheterminalblock.Then,connectexternal
DC power and insert the battery. For more information on
terminal block connection, see Connecting Terminal Block on
page12.
Loosenthescrewontherightsideofthefrontpanelandopen
thefrontpanel.
1.
2.
3.
SW
POWER
ON/OFF

11
Order List
About this Manual Introduction Installation Operation Configuration Radionode365 Maintenance Customer Service
Information
HTTP Radionode
Protocol V2
4.
5.
6.
Tightentheglandfirmly.
Coverthefrontpanelandtightenthescrews.
Ifnecessary,usescrewstosecure.Therearethreescrewholeson
thebackofthedevice.
ThereDataLoggerisequippedwithamagnetattherear.Place
theDataLoggeronasteelpanel.
SW
POWER
ON/OFF

12
Order List
About this Manual Introduction Installation Operation Configuration Radionode365 Maintenance Customer Service
Information
HTTP Radionode
Protocol V2
Connecting
Terminal
Block
IfnoexternalDCpowerissupplied,theRS485terminal
willnotfunction.
Whenconnectingcablestotheterminalblock,ensure
thattheflatcabledoesnotgetdisconnectedfromthe
frontconnector.
RS485
DC Power ConnectthePowercabletothePOWERterminal.Connectthered
cable to the + terminal, and the remaining cables to the -
terminal.
ConnecttheRS485cabletotheRS485terminal.Connectthecable
linkedtotheAterminaloftheotherdevicetotheAterminal,and
theremainingcablestotheBterminal.
FormoreinformationonhowtochangeModbuscommunication
settings,seeRS-485ModbusCommunicationonpage30.
B A
RS485
B A
RS485
+ -
POWER
5~30V
+ -
POWER
5~30V

13
Order List
About this Manual Introduction Installation Operation Configuration Radionode365 Maintenance Customer Service
Information
HTTP Radionode
Protocol V2
Batteries InsertaC-type3.6Vbatteryintothebatteryholder
Be carefulnot toconnectbatterieswithopposite
polarities.Doingsomaydamagethedevice.

14
Order List
About this Manual Introduction Installation Operation Configuration Radionode365 Maintenance Customer Service
Information
HTTP Radionode
Protocol V2
Operation
buttonuntil
appears.Holdthe buttonagain.
:Pressthe button.
Whenthedataloggeristurnedon,themodelnumberandotherkey
information is displayed with the corresponding measurements. If
no external power is supplied, the display will turn off shortly and
theDataLoggerwillentersleepmode.
ViewingChannelInformation:Toviewchannelinformation,
including measurements on sleep mode, press the button.
Press the button repeatedly to display different status
information.
SelectingaMenu:Pressthebutton,thenpressthebutton.
Pressthebuttonrepeatedlytodisplaydifferentmenuitems.
Pressthebuttontoopenthedisplayedmenu.Pressthe
buttontoexitthemenu.
TurningDataLoggerOff:Pressthebuttonandholdthe
PRESS 'P' ONE MORE TO POWER IT OFF
S W POWER
ON/OF F
●
●
●
● TurningDataLoggerOn

15
Order List
About this Manual Introduction Installation Operation Configuration Radionode365 Maintenance Customer Service
Information
HTTP Radionode
Protocol V2
Viewing
Channel
Information
Currentdateandtime
Wi-Fi network name and
signalstrength
MeasurementofChannel6
(number of particles
largestinsize)
[ONLY RN400-T2GS]
Displays the temperature
value of the chemical cell
insidetheproduct.
Elapsed time since last
transfer of measurement
data to the server &
number of datasets to
transferinthenextcycle
Press the button repeatedly to display the below channel data. A
sensorchannelthatisnotconnectedwillappearas(none).
MeasurementofChannel
LAST SENSING |S:menu 1(concentrationofPM2.5
PM2.5 18.87 ug/m3
particle)
Measurement of Channel 2
(concentrationofPM10
particles)
Typeofbatteryinsertedand
current voltage. If the
voltage is low, LOW will be
displayed.
You can select the level
of the digital filter. The
higher the number, the
less sensitive the
sensor reacts (1 level:
highest sensitive, 15
level: lowest sensitive).
You can choose from
thesettingsmenu.
LOCAL TIME |S:menu
2020-11-30 17:00
WIFI SSID dB|S:menu
xxxxxxxx, -50dB
DATA FILTER.|S:menu
SLOW LEVEL(1-15):1
LAST SENSING |S:menu
PM10 20.01 ug/m3
LAST SENSING |S:menu
PM0.5 127.36 #/m3
LAST TRANSMIT|S:menu 5
Min Ago, 9 smpl
BATTERY STAT.|S:menu
OK. |1.5Vx2|2.88V
GS CELL TEMP.|S:menu
CELL Temp: 22 C

16
Order List
About this Manual Introduction Installation Operation Configuration Radionode365 Maintenance Customer Service
Information
HTTP Radionode
Protocol V2
Viewing
Device
Information
GatewayIPaddress
Measurementinterval
DataLoggerIPAddress
Radionode365accountID
(numberofdatasetstosend=TransferInterval÷Measurement
Interval)
Whenmeasurementintervalissetto5minutesandthetransfer
intervalsetto20minutes,4datasetsaresaveduntilthe
nexttransfer.Ifdatatransferfails,datasetsaccumulateuntil
successful.
To view device information, select 1.VIEW INFO. To view the next
item,pressthebutton.Toexit,pressthebutton.
Numberofdatasetstosend
INFO|S:next, P:exit totheserverinthenext
1.HOLDING DATA: 4
cycle.
T i m e e l a p s e d s i n c e
l a s t t r a n s m i s s i o n o f
m e a s u r e m e n t d a t a t o
s e r v e r
If no external power is
connected or power failure
occurs,Batwillappear.
Measurement data
transmission to server
interval
INFO|S:next, P:exit
3.SENSING: 1 Min
INFO|S:next, P:exit
4.SENDING: 5 Min
INFO|S:next, P:exit
5.UPDATE: 1 Min Ago
INFO|S:next, P:exit 6.ID:
xxxxxxxx
INFO|S:next, P:exit
7.IP:192.168.10.13
INFO|S:next, P:exit
8.GW:192.168.1.1
INFO|S:next, P:exit
2.POWER: External DC

17
Order List
About this Manual Introduction Installation Operation Configuration Radionode365 Maintenance Customer Service
Information
HTTP Radionode
Protocol V2
INFO|S:next, P:exit
9.DN:210.220.163.82
INFO|S:next, P:exit
10.MAC:508CB16FA1B3
INFO|S:next, P:exit
12.MODEL:RN400T2PM
INFO|S:next, P:exit
13.CAL:2020-12-25
INFO|S:next, P:exit
14.MODE: ug/m3,CUM
INFO|S:next, P:exit
11.SW BUILD:20200720
ModelNo.
Firmwareversion
DNSserverIPaddress
Dateofsensorcalibration
DataLoggerMACaddress
Measurementunitandtype
ofPMrange.
CUMisthecumulative
range.
Allsettingoptions(exceptforWi-Finetwork)canbereset.Select
4.FACTORY DEFAULT.
Resetting
Data Logger

18
Order List
About this Manual Introduction Installation Operation Configuration Radionode365 Maintenance Customer Service
Information
HTTP Radionode
Protocol V2
Memory
Card for Data
Logging
OpenthefrontoftheDataLoggerandinsertamicroSDcardinto
thecardslotinsidethefrontpanel.
IfamemorycardisinstalledintheDataLogger,measurementdata
willbewrittentothememorycardasaCSVfileasfollows:
Measurementdate,timestamp,MACaddress,valuefor
Channel1,...,valueforChannel6
UseanSDcard(upto16GB)formattedwiththeFAT32
filesystem.Otherfilesystemsarenotsupported.

19
Order List
About this Manual Introduction Installation Operation Configuration Radionode365 Maintenance Customer Service
Information
HTTP Radionode
Protocol V2
Configuration
Onyoursmartphone,findtheWi-Finetworkwiththesamename
asshownonthedisplayandconnecttothenetwork.
TheDataLoggerisequippedwithavirtualWi-Firouter.Thevirtual
router allows your smartphone or tablet to be linked to Data
Loggerforconfiguration.
Select 2.CONFIG MODE(AP) to enable the virtual router. The
followingwillappearinthedisplay:
Depending on the version of your Android phone, user
identification may be required, as Data Logger is not
connectedtotheInternet.
1.
2.
SOFTAP: _RN400-
A1B3 ACCESS:
192.168.1.1
Multiplemobiledevicescannotbeconnectedtothe
DataLoggeratthesametime.

20
Order List
About this Manual Introduction Installation Operation Configuration Radionode365 Maintenance Customer Service
Information
HTTP Radionode
Protocol V2
3.
4.
5.
Changethesettingsoneachpage,thentap
Tofinishconfiguration,tapReboot.
Openyoursmartphone’swebbrowserandtype
intheaddressbar.TheSettingspagewiillappear.
"192.168.1.1"
Save.
Table of contents