INSTALLATION MANUAL
Z-LTE-WW
Z-LTE-EU
DOCUMENTATION
WARNING: The full content of this manual must be read before any operation. The module must only be used by
qualied electricians. Specic documentation is available via QR-CODE shown on page 1.
Electrical and electronic waste disposal (applicable in the European Union and other countries with recycling).
The symbol on the product or its packaging shows the product must be surrendered to a collection centre
authorized to recycle electrical and electronic waste.
The module must be repaired and damaged parts replaced by the Manufacturer. The product is sensitive to
electrostatic discharges. Take appropriate measures during any operation.
PRELIMINARY WARNINGS
The word WARNING preceded by the symbol indicates conditions or actions that put the user's safety at risk.
The word ATTENTION preceded by the symbol indicates conditions or actions that might damage the
instrument or the connected equipment. The warranty shall become null and void in the event of improper use or
tampering with the module or devices supplied by the manufacturer as necessary for its correct operation, and if
the instructions contained in this manual are not followed.
MODULE LAYOUT
LED STATUS LED meaning
PWR
(Green)
ON Log not active and status waiting for startup
Slow ashing Log active and status in normal operation
Flashing intermittently Status in operation from backup battery (battery life 1 hour)
Fast ashing Error, see Webserver diagnostics
Off Device OFF
(GSM LEVEL)
(Green)
ON Maximum signal (Level 4)
Flashing
3 ashes (Level 3)
2 ashes (Level 2)
1 ash (Level 1)
Off Minimum signal
GSM
(STATUS)
(Yellow)
Short ash Network search (200ms High / 1800 ms Low)
Long ash Connected (1800 ms High / 200ms Low)
Fast ashing Data transfer in progress (125ms High / 125ms Low)
On Voice call
MOD
(Yellow)
On Recorded on 4G network
Off Connected to another network
DO (1 and 2)
(Red)
On Digital output, relay energised
Off Digital output, relay de-energised
DI (from 1 to 4)
(Red)
ON (NPN) Digital input energised (GND closed contact)
ON (PNP) Digital input energised (contact closed to +12 V)
Off Digital input not energised
COM
(Red)
Slow ashing Activity in the RS485 or RS232 serial interface
Off RS485 or RS232 serial interfaced not used
Fast ashing Timeout in the RS485 or RS232 communication
SD
(Red)
On SD card inserted correctly
Slow ashing Activity on SD card
Fast ashing SD card error
Off No SD card
ETH LNK Flashing Connection on RJ45 active
ETH ACT Flashing Packet transit on Ethernet port
SIGNALS VIA LED ON FRONT PANEL
mm
35
mm
111
mm
102.5
Weight: 270 g;
Container: PA6, Black
TECHNICAL SPECIFICATIONS
CERTIFICAZIONI
https://www.seneca.it/products/z-lte-ww/doc/CE_declaration
https://www.seneca.it/products/z-lte/doc/CE_declaration
INSULATION
ENVIRONMENTAL
CONDITIONS
Temperature: -25– + 50°C / (-10– + 40°C if the internal UPS is used).
Humidity: 30%– 90% non condensing.
Storage temperature: -30– + 65°C / (-20– + 45°C < 6 months if the internal UPS is used).
protection rating: IP20.
ASSEMBLY IEC EN60715, 35mm DIN rail in vertical position.
INTERNAL UPS Rechargeable backup batteries. Duration: up to 1 hour.
CONNECTIONS Removable 3-way screw terminals, 5 mm pitch for cable up to 2.5 mm²,
Rear IDC10, RJ45 socket, Micro USB socket and 2 SMA for 4G antenna and GPS antenna.
POWER SUPPLY Voltage: 11 ÷ 40Vdc or 19 ÷ 28Vac 50 ÷ 60Hz. Absorption: 8W.
DIGITAL INPUTS
Number of channels 4. Congurable PNP or NPN.
Voltage OFF<4V, ON>8V (Max. 24Vdc).
Max frequency 30Hz. Absorbed current 3mA @ 12Vdc, 10mA @ 24Vdc.
TOTALIZERS 4 x 32-bit totalizers on non-volatile memory
COUNTERS: 4 x 32-bit resettable counters on non-volatile memory.
DIGITAL OUTPUTS Number of channels 2. SPDT free contact relay. Max. voltage 250Vac. Max. current 2A.
ANALOGUE
INPUTS
Number of channels 2. Congurable mA or Vdc.
Voltage input 0 – 30V. precision 0.1% of Full Scale, impedance: 200 kohm.
Current input 0– 20mA precision 0.1% of Full Scale, impedance: < 60 ohm.
Input protection 40V / 25mA. Resolution 16 bit.
COMMUNICATION
PORTS
RS485 COM1 on rear IDC10 connector, RS485 or RS232 on terminals M10-M11-M12,
Ethernet 100 base T and micro USB on side socket.
4G / LTE
WORLD WIDE
MODEM
(Z-LTE-WW)
For further information, refer to the User Manual.
MODEM 4G
(Z-LTE-EU) For further information, refer to the User Manual.
GNSS GPS / GLONASS / BeiDou(compass) / Galileo / QZSS
SD CARD SLOT Push-push type for microSD and microSDHC 32GB max.
SIM CARD SLOT Push-push type for miniSIM card 15 X 25 mm
CPU / S.O. ARM 32bit, operating system: Real Time Multitasking, built-in Webserver and on microSD.
Digital
Z-LTE-WW Z-LTE-EU
IDC10 CONNECTOR
RS485GND
RS485A
RS485B
Power Supply AC / +
Power Supply AC / -
IDC 10
1
The illustration shows the meanings of the various IDC10
connector pins if signals are to be sent via them directly.
PROCEDURE FOR MODULE SWITCH-OFF
The module is equipped with an integrated UPS that allows it to remain on even in the absence of external power. To turn
off the module, rst disconnect the external power supply and then press the PS1 button on the right side of the module for
at least 6 seconds. When the button is released, the PWR LED turns off to indicate that the module is turned off.
DIP-SWITCHES
SW1 Default settings: all DIP switches in OFF position. For more information see the USER MANUAL.
SW2
RS232 or RS485 settings on terminals 10-11-12 (COM2 serial port)
RS232 ON
RS485 OFF
DIP - SWITCH SETTINGS
ELECTRICAL CONNECTIONS
CAUTION
On rst start-up the module must be supplied without any interruptions for at least 72 hours to charge the internal batteries.
Switch the module off with the PS1 button before connecting inputs and outputs.
To meet the electromagnetic immunity requirements:
- use shielded signal cables;
- connect the shield to a preferential instrumentation earth system;
- separate shielded cables from other cables used for power installations (transformers, inverters, motors, etc...).
10
11
12
GND
A (+)
B (-)
10
11
12
GND
RX
TX
1
2
3
Tens. aus.
Vac/Vdc
Vac/Vdc
POWER SUPPLY SERIAL PORT RS485
SW2 = OFF
SERIAL PORT RS232
SW2 = ON
ANALOGUE INPUTS
Voltage Active sensor current
(4 wires)
Passive sensor current (2 wires)
(*) Not available without external power supply
The module has two
analogue inputs that
can be congured via
software as voltage
or current. For the
conguration software,
see the user manual.


+


+
+
+
DIGITAL INPUTS
NPN with internal power PNP with internal power PNP with external power
DIGITAL OUTPUTS
The module has two digital outputs
with free contacts. The gures show
the internal relay contacts available.

This manual suits for next models

1

Other Logicbus Data Logger manuals

Logicbus RTDTemp101A Specification sheet

Logicbus

Logicbus RTDTemp101A Specification sheet

Logicbus RADIONODE RN400-T2PM User manual

Logicbus

Logicbus RADIONODE RN400-T2PM User manual

Logicbus BRIDGE101A Specification sheet

Logicbus

Logicbus BRIDGE101A Specification sheet

Logicbus TC101A Specification sheet

Logicbus

Logicbus TC101A Specification sheet

Popular Data Logger manuals by other brands

VOLTCRAFT DL-141TH2K operating instructions

VOLTCRAFT

VOLTCRAFT DL-141TH2K operating instructions

MadgeTech HiTemp1400 Product Information Card

MadgeTech

MadgeTech HiTemp1400 Product Information Card

Dickson TP425 Getting started

Dickson

Dickson TP425 Getting started

Omnitronix Poll-Safe PS635 user manual

Omnitronix

Omnitronix Poll-Safe PS635 user manual

Viltrus Electronics RAY-1 Quick user manual

Viltrus Electronics

Viltrus Electronics RAY-1 Quick user manual

ASHE VZ-70 Operation manual

ASHE

ASHE VZ-70 Operation manual

Ahlborn ALMEMO 2690-8 operating instructions

Ahlborn

Ahlborn ALMEMO 2690-8 operating instructions

Avisaro 4.0 Series quick guide

Avisaro

Avisaro 4.0 Series quick guide

Mueller Mi.Net Installation and operation manual

Mueller

Mueller Mi.Net Installation and operation manual

ADAPT LOGGERS PROTON S100 user manual

ADAPT LOGGERS

ADAPT LOGGERS PROTON S100 user manual

AEMC SENTINEL SDL-V301 user manual

AEMC

AEMC SENTINEL SDL-V301 user manual

MetroCount RoadPod VT5900 Operator's guide

MetroCount

MetroCount RoadPod VT5900 Operator's guide

National Instruments NI USB-6008 user guide

National Instruments

National Instruments NI USB-6008 user guide

tempmate S2 user manual

tempmate

tempmate S2 user manual

Data Harvest DS186 manual

Data Harvest

Data Harvest DS186 manual

NexSens Technology iSIC-OEM Operation manual

NexSens Technology

NexSens Technology iSIC-OEM Operation manual

TRAMPA VESC EXPRESS manual

TRAMPA

TRAMPA VESC EXPRESS manual

Measurement Computing USB-TEMP user guide

Measurement Computing

Measurement Computing USB-TEMP user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.