Product Feature
1.Battery: 950mAh
2.Charging Current: 250mA
3.In-put Voltage: 5V4. Resistance: 1.0Ω~9.99Ω
5.Output Voltage: 4.1V, 3.6V, 3.2V. (when battery voltage is lower than
setup voltage, output voltage is current battery voltage).
Features:
Safety:
1.Over-Charge Protection: Stop charging when voltage is 4.25V.
2.Over Discharge Protection: No output when voltage is lower than
3.2V; Power off when voltage is lower than 2.5V.
1.When charging,the Red Light is flashing.
2.When the LED light turns to Cyan, device is fully charged.
Charging
Manual Mode
Auto Mode
How To Use
1.Press the Power button 5 times quickly within 2s to turn ON/OFF.
2.Hold the Power button and wait for 3 seconds to start vaping.
(You can hold the Power button for up to 20s for continuous vaping ).
3.Press the Power button 2 times quickly within 0.8s to change the voltage.
3 voltage modes:
Mode 1(Low): green-3.2V
Mode 2(Mid): blue-3.6V
Mode 3(High): purple-4.1V
1.Low battery: Red flashing light 8 times.
2.Temperature Protection: Purple flashing light 5 times.
3.Output short-circuit Alarm: Yellow flashing light 10 times.
(Tip defective, please change the the tip)
4.Open circuit: Yellow flashing light 5 times.
(Tip defective, please change the the tip)
5.Output Over- load Alarm: Cyan flashing light 12 times.
(resistance<1Ω).
6.Button Output Over-time: Indicator light flashing 2 times in the color
of current voltage mode.
Alarm Indications
Overview
Stand Assembly
Power ON/OFF
Indicator Micro USB port
Connector
Holder
Base
1.Slide the connector into the slot on the back of Holder.(See Pic.1)
2.Plug the connector into the hole on the base. ( See Pic.2)
MAX GLASS
Cleaning
brush
Silicone
Mouthpiece
(Stopper)
Make sure Hole A is aligned with
Hole B to get the max airflow,
twist the position of Hole A and
Hole B to adjust the airflow.
A
B
C
Cap
Base
Quartz Coil
Cleaning methods
1.Press the Power button 3 times within 1.5s to trigger the
exclusive mode for dabbing-Auto Mode.
2.In Auto Mode, the device preheats for 15s (indicator light flashing),
then automatically heats for 30s (indicator light keeps on).
3.After automatically heating for 30s, the device stops heating
for Auto mode and goes back to Manual Mode, press the
Power button 3 times to enter Auto Mode again.
4.In Auto Mode, adjust the voltage by pressing the button 2 times within 0.8s.
3 voltage modes:
Mode 1(Low): green-3.2V
Mode 2(Mid): blue-3.6V
Mode 3(High): purple-4.1V
5.In Auto Mode, press the Power button 3 times within 1.2s to exit Auto Mode.
6.In Auto Mode, the device has temperature protection (Purple flashing
light 5 times, the device will power off automatically, and go back to Standby
Mode). Once the alarm is triggered, please allow a minimum of 10mins
for it to cool down before using the device again.