STEP 3
Part Number: 50125
Digital Control Center
“How To Confirm Program”
DATE ISSUED: December 2014
MODELS EFFECTED: CS and LG Series
Press and hold the "Prime" and "Temp" buons together, count to
6 or wait unl the display reads 0 on the le (this is variable "0").
The "0" will be ashing. The number on the right will either be
25 or 30
Press "power" buon to acvate the control. The
setpoint temp will show up and will either be 450, 350
or 375. This determines which program column
numbers to use.
STEP 1 STEP 2
Use the "up arrow" to change the ashing number on
the le to the number or leer needing to be changed.
(variables are numbers 0 - 9 and then leers A - S)
NOTE: ignore the changing numbers on the right.
STEP 4
When you reach the number/ leer to be changed, press and
release quickly, the "Prime" buon once. The number/leer on the
le and the 4 blue dots will be ashing. While the 4 blue dots are
ashing, the number on the right can be changed using the temp
arrows.
STEP 5
Use the up or down temp arrows to change the number
on the right to the desired number.
STEP 6
Press the "Prime" buon once, quickly, the number/leer on the
le will stay ashing, and the four blue lights will go o.
* If necessary, cycle to the number/leer on the le to the next
variable needing to be changed, and repeat steps 3 thru 6.
* If no other variables need to be changed move to step 7