Louroe ASK-4 350 User manual

Ask-4® #350 is a single zone audio monitoring system for direct connection to an PoE complaint IP camera or Video
Server. This kit comes with a UL listed IF-PX which is a POE inline interface and a Verifact A Microphone. The IF-PX
extracts power from an Ethernet line to supply power to remote microphones, Speaker/Microphones or other 12V
devices. It has a terminal block to connect to the microphones (one-way audio) and speaker/microphones (two-way
audio). The 3.5mm stereo audio output and input jacks are for direct connection to the audio inputs and outputs of an IP
Camera. This unit also offers volume control for the audio output. Supports both Mode A and Mode B power options of
IEEE802.3af
The Verifact A is an omni-directional, low impedance, electret condenser microphone with built-in preamp for producing
line level audio. It is housed in a high impact ABS dome designed for ceiling or wall mounting. Normal pick-up pattern is
approximately 15’ from the microphone location, all direction or within 30’ diameter circle
WIRING REQUIREMENTS
Ask4_350_inst 2/15
ASK-4 #350
AUDIO MONITORING SYSTEM
INSTALLATION AND OPERATING INSTRUCTIONS
6955 VALJEAN AVE, VAN NUYS, CA 91406
PH: (818)994-6498 / FAX: (818)994-6458
®
®
®
Between IF-PX & Louroe Verifact Microphone:
2 Conductor shielded cable, 22 gauge with a 24 gauge
drain wire.
IF-PX
®
VERIFACT A MICROPHONE 3.5mm STEREO PATCH CABLE
Contents Description
IF-PX PoE in-line Interface
Used to extract power from an Ethernet
connection to power Louroe microphones,
speaker/ microphones and external devices
that require a 12Vdc supply.
Verifact A Microphone Line Level, Electret condenser microphone
with preamp. Picks up normal sounds within 30’
circle. May be located Up to 1000’ from IF-PX.
Patch Cable Single Cable with 3.5mm Stereo Plugs on each
end
Used for connecting the IF-PX to the Audio
Input of an IP camera or encoder
U
®
Page 1 of 8
LOUROE ELECTRONICS® 6 9 5 5 VA L J E A N AVENUE, VAN NUYS, CA 91406 TEL (818) 994-6498 FAX 994-6458
(818)
U
R
T
E
C
D
A
I
F
N
U
T
N
H
A
E
M
FIG. 1
®

Page 2 of 8
LOUROE ELECTRONICS® 6 9 5 5 VA L J E A N AVENUE, VAN NUYS, CA 91406 TEL (818) 994-6498 FAX 994-6458
(818)
ILLUSTRATED PARTS
1
2
3
4
5
6
7
8
9
10
Power+Data Output Jack
MIC Out Adjust
DC Out Terminal Block
DC IN Power Jack
Mic/Speaker Audio Terminal Block
Audio Input Jack
Data Out Only Jack
Power+Data Input Jack
Audio Output Jack
Power Indicator
Connects to PoE IP Cameras and/or Encoder
Adjust the audio output gain of the microphone
Receives 12Vdc power from external power supply (not supplied)
Receives wiring from Louroe Verifact Microphone and/or AOP-SP series
Connects to data input of Non-PoE IP Cameras, and Encoders.
Connects to PoE (802.3af) Switch or PoE (802.3af) Midspan
Lights Green indicating power is present to the unit
Connects to audio input of IP cameras,
Encoder, etc.
Provides audio to IP Cameras, Encoder, etc.
Receives audio from IP Camera, Encoder, etc. and connects to audio
output for talkback operation
Provides +12Vdc voltage to power external equipment such as
Non-PoE cameras, encoders, relays, etc.
FIG. 2
POE INTERFACE/POWER EXTRACTOR
POWER + DATA
OUT
IEEE 802.3af
POE
MIC OUT
ADJUST
DC OUT
GND + 12V
DC IN
+12V
AUDIO
DATA OUT
P/N:LE-520
MIC/SPEAKER
OUT
IN
AUDIO
ABC SP
POWER + DATA
IN
123456789
10
REAR PANEL FRONT PANEL
INSTALLATION AND OPERATING INSTRUCTIONS
1. Do not connect non-PoE complaint devices to Power+Data Output Jack . Failure to do so may damage the
powered equipment.
Plan ahead where to install before making any connections.The IF-PX is designed to operate within 6’ of the camera so
the audio cables supplied can be connected between the IF-PX and camera. The maximum distance between the IP
camera and PSE is 100m or 328’.
2. Do not connect wiring from external microphone to the Mic/Speaker Audio Terminal Block until all the
ethernet cables (RJ45) are connected and power is present to the camera. Failure to do so in sequence, the
camera may not receive power.
CAUTION
NOTES
5
1
FIG. 2
Ask4_350_inst 2/15

INSTALLATION AND OPERATING INSTRUCTIONS
Page 3 of 8
LOUROE ELECTRONICS® 6 9 5 5 VA L J E A N AVENUE, VAN NUYS, CA 91406 TEL (818) 994-6498 FAX 994-6458
(818)
10
CONNECTING PoE SWITCH TO PoE IP CAMERA OR ENCODER (See Fig. 3)
1. Connect Ethernet cable from PSE (Power Source Equipment) to the Power+Data Input Jack of the IF-PX.
2. Connect Ethernet cable from camera to Power+Data Output Jack of the IF-PX. Camera should now have power
and data running through it. Power Indicator lights up.
3. Microphone Connection :
a) Connect a 2 cond. shielded cable to the terminal block of Louroe’s Verifact A microphone. Connect the other end to
the pluggable header (Mic/Speaker Audio Terminal Block ) of the IF-PX. Connect terminal A of microphone to
terminal A of IF-PX; terminal B of microphone to terminal B of IF-PX; terminal C of microphone to terminal C of IF-
PX. Terminal SP of IF-PX is not used when connecting microphone only (one-way listen).
b) Using the patch cable (stereo plug to stereo plug), connect the Audio Output Jack of the IF-PX to the audio input
of the camera.
c) Adjust the Mic Out Adjust potentiometer (as needed) by rotating it clockwise to increase the microphone output to
the camera, or counterclockwise to decrease. This potentiometer is factory set for a gain of 0dB output.
(one-way listen)
See
interconnection diagram(Fig 3) on page 5.
4. Setup camera for video and audio monitoring. Use an amplified speaker on the computer to test the audio coming
from the microphone. See camera user manual for setting up the camera to the network.
CONNECTIONS AND OPERATIONS
The IF-PX can share PoE power with most Class 2 IP cameras and Encoders, check that the power requirements
of the equipment does not go beyond the IF-PX power output. See IF-PX power output below.
12Vdc, 850mA with a Louroe microphone connected (no camera sharing power with IF-PX)
12Vdc, approx. 400mA when sharing power with a typical class 2 IP camera.
CONNECTING PoE SWITCH TO NON-PoE IP CAMERA OR ENCODER (See Fig 4)
1. Connect Ethernet cable from PSE (Power Source Equipment) to the Power+Data Input Jack of the IF-PX.
2. Connect Ethernet cable from Non-PoE Encoder or camera to Data Out Only Jack of the IF-PX.
8
1
5
9
2
8
7
3. Connect 2 wires to the DC Out Terminal Block . At least 20 AWG wires should be used between the IF-PX and the
encoder or camera. Positive 12Vdc connects to terminal marked “+12Vdc” of IF-PX. Negative 12Vdc or ground
connects to terminal marked “GND” of IF-PX. Connect the other end of these 2 wires to the power jack or terminal
block of the encoder or camera. If the encoder or camera has a 2.1mm power jack, an adapter (2-pin terminal block to
2.1mm male plug) can be used. Connect the wires to the 2-pin terminal block (observe polarity) of the adapter. Plug
the adapter to the 2.1mm power jack of the encoder or camera.
4. Repeat same procedure when connecting Louroe Verifact microphone to camera or encoder (steps 3 and 4 of -
Microphone Connections).
3
Ask4_350_inst 2/15
®

CONNECTING NON-PoE SWITCH TO NON-PoE CAMERA OR ENCODER (See Fig. 5)
1. Connect Ethernet cable from Non-PoE Switch to the Power+Data Input Jack of the IF-PX.
2. Connect Ethernet cable from a Non-PoE Encoder or Camera to Data Out Only Jack of the IF-PX.
3. Connect DC Out Terminal Block to the power input jack of the encoder or camera. This Terminal block supplies
12Vdc power to the camera or encoder. It can also provide power to other external equipment such relays, etc. that
require a 12Vdc power. Connect 2 wires to the DC Out Terminal Block . At least 20 AWG wires can be use between
the IF-PX and the encoder or camera. Positive 12Vdc connects to terminal marked “+12Vdc” of IF-PX. Negative 12Vdc
or ground connects to terminal marked “GND”of IF-PX. Connect the other end of the 2 wires to the power jack or
terminal block of the encoder or camera. If the encoder or camera has a 2.1mm power jack, an adapter (2-pin terminal
block to 2.1mm male plug) can be used. Connect the wires to the 2-pin terminal block (observe polarity) of the
adapter. Plug the adapter to the 2.1mm power jack of the encoder or camera.
4. Connect an external power supply (not included) to the DC In Jack to power the IF-PX and the encoder or camera.
We recommend using a 12Vdc, 2A power supply.
5. Repeat same procedure when connecting Louroe Verifact microphone (steps 3 and 4 of Microphone Connections).
8
7
3
3
4
INSTALLATION AND OPERATING INSTRUCTIONS
Shipping Weight of the kit 3 Lbs
SPECIFICATIONS: IF-PX (UL Listed)
Ethernet Connectors
Voltage Input
DC Output
Operating Temperature
RJ45 CAT 5 Input and Output Jacks
12Vdc, 800mA
-20°C to +65°C
Optional Power Supply 12Vdc, 2A, Ext. Power Supply
(Not Supplied)
Connectors
Audio Output/Input
Audio Output Gain
Material
up to +15dB
Black Anodized Al 14 Ga
Line level
RJ-45, DC Jack,
Terminal Block for Microphone/Speaker
3.5mm Stereo Jacks for Audio IN/OUT
Dimensions
Weight 13oz.
6”L x 3 1/2”W x 2 1/8”H
36V - 57V
SPECIFICATIONS (Microphone - Model A)
Frequency response
Current drain
Output
Supply voltage
50 Hz to 15 kHz ± 1 dB
10 mA
Line Level (0 dB 600W@ 1 kHZ)
12Vdc
Dimensions
Weight 3.5 oz
4"Dia x 1 ½"H
Ask4_350_inst 2/15

INSTALLATION AND OPERATING INSTRUCTIONS
Page 4 of 8
LOUROE ELECTRONICS® 6 9 5 5 VA L J E A N AVENUE, VAN NUYS, CA 91406 TEL (818) 994-6498 FAX 994-6458
(818)
ABC
C
B
A
POWER+DATA OUT
AUDIO IN
AUDIO OUT
2 COND SHIELDED 22AWG
WITH 24AWG DRAIN WIRE
POWER+DATA IN
PoE (802.3af) SWITCH
INTERCONNECTION DIAGRAM BETWEEN A PoE SWITCH, IF-PX, IP CAMERA
AND VERIFACT A MICROPHONE FOR ADDING ONE-WAY AUDIO
PoE IP CAMERA
VERIFACT A MICROPHONE
IF-PX
FIG. 3
3.5MM STEREO PATCH CABLE
Ask4_350_inst 2/15

ABC
C
B
A
LAN
OUT
IN
O
I
D
U
A
OUT
IN
INSTALLATION AND OPERATING INSTRUCTIONS
Page 5 of 8
LOUROE ELECTRONICS® 6 9 5 5 VA L J E A N AVENUE, VAN NUYS, CA 91406 TEL (818) 994-6498 FAX 994-6458
(818)
FIG. 4
INTERCONNECTION DIAGRAM BETWEEN A PoE SWITCH, IF-PX, NON-PoE ENCODER
AND VERIFACT A MICROPHONE UNIT FOR ADDING ONE-WAY AUDIO
POWER+DATA
VERIFACT A MICROPHONE
VIDEO IN
VIDEO OUT
ANALOG CAMERA
NON-PoE ENCODER
IF-PX REAR
IF-PX FRONT
POWER SUPPLY
OF ENCODER
12VDC OUT TO
POWER CAMERA
AUDIO OUT
DATA ONLY
PoE (802.3af) SWITCH
Ask4_350_inst 2/15

ABC
C
B
A
LAN
OUT
IN
O
I
D
U
A
OUT
IN
INSTALLATION AND OPERATING INSTRUCTIONS
Page 6 of 8
LOUROE ELECTRONICS® 6 9 5 5 VA L J E A N AVENUE, VAN NUYS, CA 91406 TEL (818) 994-6498 FAX 994-6458
(818)
INTERCONNECTION DIAGRAM BETWEEN A NON PoE SWITCH, IF-PX, NON-PoE ENCODER
AND VERIFACT A MICROPHONE FOR ONE-WAY LISTEN
NON-PoE SWITCH
AUDIO OUT
VERIFACT A MICROPHONE
2 COND SHIELDED CABLE
ANALOG CAMERA
12VDC,2A EXTERNAL
POWER SUPPLY
(Not Supplied)
IF-PX REAR
SUPPLIES 12VDC TO
CAMERA OR ENCODER
IF-PX FRONT
ENCODER POWER
SUPPLY
AUDIO OUT
VIDEO IN
AUDIO IN
FIG. 5
Ask4_350_inst 2/15

INSTALLATION AND OPERATING INSTRUCTIONS
Page 7 of 8
LOUROE ELECTRONICS® 6 9 5 5 VA L J E A N AVENUE, VAN NUYS, CA 91406 TEL (818) 994-6498 FAX 994-6458
(818)
WARRANTY
LOUROE ELECTRONICS® warrants that at the time of shipment products manufactured by LOUROE ELECTRONICS® to be free of defects in material and workmanship.
Should a defect appear within one year (12 months) from date of shipment, LOUROE ELECTRONICS® will, at its sole discretion, repair or replace the defective equipment.
This equipment shall not be accepted for repair or return without prior notification by LOUROE ELECTRONICS®.
This warranty does not extend to any Louroe product that has been subjected to improper or incorrect installation, misuse, accident, or in violation of installation
instructions provided by LOUROE ELECTRONICS®.
Returned shipments to LOUROE ELECTRONICS® shall be at customer’s expense. LOUROE ELECTRONICS® will return the equipment prepaid via best way.
MANUFACTURED
IN THE
IMPORTANT NOTICE
When this equipment is used as part of an audio
monitoring system, the law requires that the public be
given notice of AUDIO MONITORING ON THE
PREMISES. A decal notice is included with each
microphone shipped.
Federal Law References:
Federal Regulations, US Code, Title 18. Crime and
Criminal Procedure, Sec 2510.
AUDIO
MONITORING
On
These Premises
TM
Ask4_350_inst 2/15
Table of contents
Other Louroe Speakers System manuals