6. Usage and Operation
1. Setting DMX512 adress:
When using a DMX512 console to control the spotlight, the fixture should
be set to an address, ranging from 1-512. Therefore press the address
up/down buttons a single time for single steps, or press the buttons
longer for fast and continuous steps.
2. Manual host 16bit dimming mode:
The DMX512 is not needed in this mode, but the fixture must be set to
be host. It will send DMX512 signal to control the following units that are
connected to the signal line. This makes the other units to change the
brightness according to the host. When using this function, you should
pay attention that no signal from a light console is connected in between.
Press the dimmer up/down buttons, the current state is set to manual
mode of host, 16-bit dimming mode. Single-press the up/down-buttons,
the brightness will be increasing or decreasing in single steps. When you
press the up/down-buttons longer, the brightness will change fast and
continuously ranging from 0-65535.
Note: This state will be saved automatically after you stop operating for
10 seconds.
3. Manual test 16-bit dimming mode:
The function of this mode is to test whether one single light can be
operated normally, it will not send DMX512 signal to influence the lights
that are connected with it.
Press address up and down button at the same time, press dimmer
up/down-button to dim
Test Dimm
XXXXX will be displayed, XXXXX is the brightness value when dimming.
4. When the light is in the received state, it can´t receive signal or can´t
connect the signal wire. The backlight of the liquid crystal display will
flash, when the signal wire is connected successfully.