Lucci LEDlux STARLIGHT 170740 User manual

Installation Instructions
1 | P a g e v 1 . 0 ( 0 9 / 2 0 1 8 )
STARLIGHT ADJUSTABLE LED DOWNLIGHT
SKU# 170740, 170741, 170742, 170743
Rated Voltage 200-240V~ 50/60Hz
Thank you for purchasing this quality Lucci product. To ensure correct function and safety, please read and follow all
instructions carefully before assembly, installation and use of this luminaire. Please keep instructions for future reference.
Warranty
This luminaire is covered by a 5 year warranty. The warranty is from date of purchase, not the date of installation.
If the luminaire is not assembled and installed by a licensed electrician the warranty will be void.
Please retain proof of purchase and evidence of installation by a licensed electrician for any warranty enquiries.
Warranty will be void if there is any damage due to improper usage or modification to the luminaire.
Failure to comply with the instructions in this manual may increase the risk of damage or injury and will void warranty.
This luminaire is not suitable for use with dimmer switches.Warranty will be void if the luminaire is used on the same
circuit which has a dimmer switch.
Installation Requirements
Must be installed by a licensed electrician.
All wiring and installation of the luminaire must adhere to the latest local and national wiring rules.
eg. AS/NZS 3000 Electrical Installations.
This is a Class II luminaire. This must be maintained during wiring and installation.
Select a suitable location for installation:
This luminaire is suitable for indoor use only.
The mounting point must support 2 times the weight of the luminaire.
This luminaire is not suitable for dimming and should not be used with a circuit which has a dimmer.
Warranty will be void if the luminaire is used on the same circuit which has a dimmer switch.
This recessed luminaire has an insulating ceiling type IC-4 rating. Building insulation material can safely be
exposed continuously to temperatures up to 90°C may abut and cover the luminaire. (Please refer to the
Clearance Information section and the IC-4 Rating section in this instruction manual for further details)
If loose fill insulation or thermal insulation is not fixed into position or if there are loose combustible materials (e.g.
leaves or combustible materials stored in the roof space), a barrier or guard is required as per the Clearance
Information section in this instruction manual.
Take note of the clearance values. Do not remove any structural members for the installation of this luminaire.
The LED driver must be placed at least 100mm away from the LED downlight module to allow for cooling.
The LED driver can be placed under the insulation. (Please refer to the Clearance Information section in this
instruction manual for further details)
Take care not to pull any electrical wires during unpacking as this may damage the connection.
Lay out all the components on a smooth surface and make sure there are no components missing before
assembling. If parts are missing, return the complete product to the place of purchase for inspection or replacement.
Check whether the luminaire has been damaged during transport. Do not operate/install any product which appears
damaged in any way. Return the complete product to the place of purchase for inspection, repair or replacement.
Ensure power to the circuit you are working on has been switched OFF before commencing any electrical work.

Installation Instructions
2 | P a g e v 1 . 0 ( 0 9 / 2 0 1 8 )
Installation Directions
1. Remove all packaging material from the luminaire and be careful not to throw away accessories that may be hidden
within the packaging material.
2. Cut a hole of Ø 50mm into the installation location. (Fig A)
3. Remove the cover from the 240V side of the LED driver and connect the mains supply wire. (Fig B)
4. Ensure the wires are secure and no bare wires are exposed. Install the cover back over the LED driver. (Fig B)
5. Push the springs up and install the LED downlight module through the cut-out hole. (Fig C)
6. Ensure all the clearance values are maintained during and after installation of the LED downlight module, LED
driver, thermal insulation, loose fill insulation, loose combustible materials and any structural members. (Fig D)
Please refer to the Clearance Information section and the IC Rating section in this instructions for further details.
7. Press the lamp body to tilt at your preferred lighting angle.
8. After the installation, switch on the luminaire to test all the lighting functions and enjoy your new luminaire.

Installation Instructions
3 | P a g e v 1 . 0 ( 0 9 / 2 0 1 8 )
Clearance Information –AS/NZS 3000 Wiring Rules
IC Rating –AS/NZS 60598.2.2 : 2016
1. A closed luminaire that allows building insulation to come into contact with its sides and to cover it.
2. Type IC-4 recessed luminaire can be used together with building insulation that can safely be
exposed continuously to temperatures up to 90°C may abut and cover the luminaire;
3. The declared IC-4 rating is based on the default testing ambient temperatures 25°C according to
the standard.
Safety tips
Always ensure the power is OFF and the luminaire has cooled down before performing any maintenance, cleaning or
making any adjustment to the fitting.
To avoid injury or damage to the luminaire, ensure that power leads and screws are secure before connecting the
power.
Select a suitable location away from liquids and hazards.
To clean, wipe with a soft damp cloth. Do NOT soak or immerse the luminaire in water or other liquids.
Ensure that the luminaire does not come in contact with corrosive chemicals/solvents or abrasive cleaners etc.
The light source in this luminaire is not replaceable; when the luminaire reaches its end of life the whole luminaire
shall be replaced.
LOCATION
DISTANCE
DESCRIPTION
A
50 mm
(Minimum)
Clearance between the top of the recessed luminaire and any combustible materials,
building elements or objects above it.
B
50 mm
(Minimum)
Clearance between the side of the recessed luminaire and any combustible materials,
building elements or objects.
C
0 mm
(Abutted)
Insulation can be abutted against the side of recessed luminaire and covered as per
IC Rating. See IC Rating section for more details.
D
100mm
Auxiliary equipment/driver/transformer must be placed 100mm away from the luminaire.
It can be placed under the thermal insulation and covered.
RISKOFFIRE–Requiredclearance fromstructural members and building elements
SCB = 50 mm HCB = 50 mm

Installation Instructions
4 | P a g e v 1 . 0 ( 0 9 / 2 0 1 8 )
Specifications
SKU #
170740
170741
170742
170743
Colour
White
Black
White
Black
Rated Voltage
INPUT: 200-240V~ 50/60Hz,
OUPUT: 3-9VDC, 300mA Constant Current
Rated Wattage
3.5W
LED Specs
Sunpu LED, 3000K, 280 lumens,
CRI >80, Non-dimmable
Sunpu LED, 4000K, 280 lumens,
CRI >80, Non-dimmable
Weight
0.2kg
Cut-out Size
50mm
IP Rating
IP40 (for the LED module after installation)
IP20 (for LED driver)
Recessed
Luminaire Rating
IC-4
Dimensions
H:44mm Dia:60mm
This manual suits for next models
3
Table of contents
Other Lucci LEDlux Light Fixture manuals
Popular Light Fixture manuals by other brands

Blizzard Lighting
Blizzard Lighting ProPar Seven 4 user manual

Larson Electronics
Larson Electronics EPL-HB-150LED-PND instruction manual

Kason
Kason GreenGuard 1810LC Series instruction sheet

elektraLite
elektraLite UFO 8 user manual

Triarch
Triarch 29220/2 Assembly instruction

Thorlux Lighting
Thorlux Lighting Vandalux manual