INSTALLATION GUIDE |CELESTE™- 24V LED TAPE LIGHT | Last Modied: 032619-1.0 |1 OF 5
INSTALLATION GUIDE
CELESTE™24V FLEXIBLE LINEAR LIGHTING
SAFETY & WARNINGS
DO NOT CONNECT DIRECTLY TO HIGH VOLTAGE POWER!
Read all warnings and installaon instrucons thoroughly.
WARNING
DO NOT CONNECT DIRECTLY TO HIGH VOLTAGE POWER!
Read all warnings and installaon instrucons thoroughly.
WARNING
WARNING!
DO NOT CONNECT DIRECTLY TO HIGH
VOLTAGE POWER!
Read all warnings and installation instructions
thoroughly.
HANDLE PRODUCT WITH CARE!
DO NOT BEND LED STRIP
LIGHT TO A DIAMETER LESS
THAN 4 INCHES.
4 in.
DO NOT BEND LED STRIP LIGHT
ON A HORIZONTAL PLANE.
DO NOT COVER STRIP LIGHT WITH
ANY MATERIALS.
DO NOT FOLD, CREASE, OR
TWIST LED STRIP LIGHT.
DO NOT POWER STRIP
LIGHT WHILE ATTACHED TO
SPOOL OR TIGHTLY COILED.
1.Install in accordance with national and local electrical
code regulations.
2.This product is intended to be installed and serviced by
a qualied, licensed electrician.
3.Do not modify or disassemble this product beyond
instructions or the warranty will be void.
4.Do not submerge, or install within 5 feet of a swimming
pool.
5. All plastics are affected by the elements and may shift
in color and other properties after product installation,
particularly with direct exposure to sun, chlorinated
water, and other chemicals.
6.Only install with a Listed Class 2 DC LED driver.
7.To avoid Voltage Drop, ensure wire gauge used with
LED Strip Light is sufcient. Refer to Voltage Drop Chart.
8.Do not exceed maximum run recommended for Strip
Light.
9.CELESTE™LED Strip Light is designed to be cut at
designated cut points only. Cutting anywhere other than
the cut points will result in damage to the Strip Light.
10. Failure to follow safety warnings, and installation
instructions will void the warranty for this product.
POWER SUPPLY
CLASS
2

INSTALLATION GUIDE |CELESTE™- 24V LED TAPE LIGHT | Last Modied: 032619-1.0 |2 OF 5
INSTALLATION GUIDE
CELESTE™24V FLEXIBLE LINEAR LIGHTING
Prior to installation, verify all components (LED Tape, Driver, Control, &
Accessories) are compatible. Congure and pre-test your LED system prior to
installation to ensure all components are operating correctly.
SHOCK HAZARD! May result in serious injury
or death.
Turn power OFF at circuit breaker prior to
installation.
+24V
-
+
-
+24V
-
+
-
+24V
-
+
-
+24V
-
+
-
1) Class 2 Driver 2) Control 3) Tape Light
Refer to SYSTEM DIAGRAMS.
WIRE GAUGE & VOLTAGE DROP
Ensure applicable wire is installed between driver, xture,
and any controls in between. When choosing wire, factor in
voltage drop, amperage rating, and type (in-wall rated, wet
location rated, etc.)
CUT TAPE LIGHT TO DESIRED LENGTH
+ 24V
-
+
-
+ 24V
-
+
-
+ 24V
-
+
-
+ 24V
-
+
-
+ 24V
-
+
-
+ 24V
-
+
-
+ 24V
-
+
-
+ 24V
-
+
-
Cut at line indicated with scissors icon.
PREPARE CONNECTOR
Gently pull open connector window. Note the +/- polarity
markings of the tape light.
-
+
24V
-
+
-
+
24V
-
+
-
+
24V
-
+
-
+
24V
-
+
-
+
24V
-
+
--
+
-
+
24V
-
+
-
+
INSERT TAPE LIGHT INTO CONNECTOR
OPEN CELESTE™SPLICE CONNECTOR
UNSCREW TERMINAL BLOCK CONNECTOR
OPTION : TERMINAL BLOCK CONNECTOR
OPTION : CELESTE™SPLICE CONNECTOR
TERMINAL BLOCK CONNECTOR
Never cut tape attached to a live circuit. Do not exceed Class 2
Limit when loading CELESTE™Connectors.
Firmly insert with 3M™Adhesive backing still intact to
Tape Light.
INSTALLATION
1TURN POWER OFF AT CIRCUIT BREAKER
2
DETERMINE LOCATION TO INSTALL
COMPONENTS
3
4
5
a
b
a
a
b

INSTALLATION GUIDE |CELESTE™- 24V LED TAPE LIGHT | Last Modied: 032619-1.0 |3 OF 5
INSTALLATION GUIDE
CELESTE™24V FLEXIBLE LINEAR LIGHTING
Prior to mounting, attach to Class 2 LED Driver, turn on power and
test connection to ensure system is operating properly. Turn off
power again before mounting.
ab
+
-
+ 24V
-
+
-
Clean surface before mounting.
MOUNT TAPE LIGHT
TURN POWER ON AT CIRCUIT BREAKER
SYSTEM WORKING IMPROPERLY?
Turn power OFF at circuit breaker and verify all connections.
Review SYSTEM DIAGRAMS and TROUBLESHOOTING or
call our Technical Support line at 877.817.6028.
Peel off 3M™Adhesive Backing. Ensure ambient
temp is minimum 50 ° F (10 ° C) or tape will not
adhere properly.
Tear off backing along connector edge.
Adhere to a smooth, dry surface, working one end
to the other.
INSTALLATION (CONT.)
8.1
8.2
Using Phillips Head Screwdriver, fasten connector to Strip
Light.
Press top down onto Strip Light.
-
+
24V
-
+
-
+
24V
-
+
-
+
24V
-
+
-
+
24V
-
+
-
+
24V
-
+
-
+
24V
-
+
-
+
24V
-
+
-
+
TERMINAL CONNECTOR
Ensure contact/solder points of tape light are directly
over connection prongs within connector.
SECURE STRIP LIGHT
-
+
24V
-
+
-
+
24V
-
+
-
+
24V
-
+
-
+
24V
-
+
-
+
24V
-
+
-
+
24V
-
+
-
+
24V
-
+
-
+
24V
-
+
-
+
24V
-
+
-
+
24V
-
+
-
+
24V
-
+
--
+
Ensure connection prongs pierce completely
through CELESTE™LED Tape Light.
CELESTE™SPLICE CONNECTOR
CELESTE™SPLICE CONNECTOR
6
b
a
b
7TEST CONNECTION
8
9

INSTALLATION GUIDE |CELESTE™- 24V LED TAPE LIGHT | Last Modied: 032619-1.0 |4 OF 5
INSTALLATION GUIDE
CELESTE™24V FLEXIBLE LINEAR LIGHTING
TROUBLESHOOTING
Symptom Common Cause
Tape Light does not
illuminate
• Circuit breaker is OFF or tripped.
• Incorrect wiring. Polarity of Low Voltage V+ and V- are reversed. Check connection at every connection point to ensure
polarity is not reversed.
Tape Light Overheats • Ambient temperature above rating. Ensure tape light is installed in environment -4° ~ 122°F (-20° ~ 50°C).
• Voltage input is higher than rated voltage.
Fixture ickers randomly,
may shut off
• Connection is not secure. Check connection at Terminal or CELESTE™ splice connector and ensure Terminal screws, or
metal prongs of CELESTE™ splice connector are pierced through Tape Light Solder pads.
Shift in brightness and/
or color
• Review Tape Light maximum series run limit. Exceeding will cause voltage drop, decreasing brightness and/or color shift.
• Review Voltage Drop Chart. Incorrect wire gauge may cause voltage drop and noticeable shift in brightness and/or color.
Tape Light turns on/off
repeatedly
• Driver is overloaded or overheated. An overloaded/overheated driver will trip the internal auto-reset (of driver) repeatedly,
turning the system on/off.
Wire
Gauge 10 W
.42 A 20 W
.83 A 30 W
1.3 A 40 W
1.7 A 50 W
2.1 A 60 W
2.5 A 70 W
2.9 A 80 W
3.3 A 90W
3.75 A 100 W
4. 2 A
20 AWG 85 ft. 43 ft. 27 ft. 21 ft. 17 ft. 14 ft. 12 ft. 11 ft. 9 ft. 8 ft.
18 AWG 134 ft. 68 ft. 45 ft. 33 ft. 27 ft. 22 ft. 19 ft. 17 ft. 15 ft. 14 ft.
16 AWG 215 ft. 109 ft. 72 ft. 54 ft. 43 ft. 36 ft. 31 ft. 27 ft. 24 ft. 22 ft.
14 AWG 345 ft. 174 ft. 115 ft. 86 ft. 69 ft. 57 ft. 49 ft. 43 ft. 39 ft. 36 ft.
12 AWG 539 ft. 272 ft. 181 ft. 135 ft. 108 ft. 90 ft. 77 ft. 68 ft. 61 ft. 56 ft.
10 AWG 784 ft. 397 ft. 263 ft. 197 ft. 158 ft. 131 ft. 112 ft. 98 ft. 97 ft. 82 ft.
24V Voltage Drop & Wire Length Distance Chart
Determine load size. Let’s assume load
is 55 W. Round up to nearest load.
Determine distance from driver to load.
Let’s assume the distance is 20 ft.
Round up to nearest distance.
It’s recommended to install 18 AWG to
eliminate excess voltage drop.
VOLTAGE DROP CHARTS
ADDITIONAL RESOURCES
For best performance and lumen output, ensure proper wire gauge is installed to compensate for voltage drop of low voltage circuits.
Visit the on-line product page at www.LucettaLighting.com for
individual LED Tape Light product specications & warranty
information.
Voltage Drop Chart Guide
1
2
3

INSTALLATION GUIDE |CELESTE™- 24V LED TAPE LIGHT | Last Modied: 032619-1.0 |5 OF 5
Lucea Lighng is a division of Elemental LED Inc.
885 Trademark Drive, Suite 200 | Reno, NV 89521 | (833) 533-7732| info@LuceaLighng.com
© 2019 Elemental LED Inc. All rights reserved. Specicaons are subject to change without noce.
INSTALLATION GUIDE
CELESTE™24V FLEXIBLE LINEAR LIGHTING
SYSTEM DIAGRAMS
The following diagrams are provided as example system designs. For information regarding larger systems or systems not
pictured below, please see our web page or contact technical support. Always review each component installation guide for
detailed and up-to-date wiring instructions. Install in accordance with national and local electrical codes.
L
N
G*
N
LV+
V−
120VAC On/Off Switch Class 2 Low Voltage Driver2
Installed in Junction Box7
V+
V-
LED Tape Light / Fixture
8
Install appropriate wire gauge / type
V+
V-
AC Power
50/60Hz
INPUT
OUTPUT
Traditional ON/OFF Switch System
AC Power
50/60Hz
Compatible Dimming Control
or On/Off Switch5
LED Tape Light / Fixture8
L
Install appropriate wire gauge / type
OMNIDRIVE®Dimmable Driver6
Some dimmers may require an
additional neutral wire connection.
NNGND*
N
LV+
V−
V+
V−
V+
V−
INPUT
OUTPUT
Class 2 Low Voltage Driver2
Installed in Junction Box7
0-10V Dimmer System
OMNIDRIVE®Electronic Dimmable Driver
System
Magnetic Dimmable Driver System
1. Driver may not require a fault ground connection. Refer to driver specications for additional information.
2. Install a compatible Class 2 driver. Refer to each driver specication sheet for full power ratings & load deratings.
3. Install a compatible Class 2 0-10V driver. Refer to each driver specication sheet for full power ratings & load deratings.
4. Determine the number of low voltage outputs of the driver when installing multiple PWM controllers/dimmer switches. No more than one PWM controller/dimmer switch can be attached to a single
output of the driver.
5. Install a compatible dimming control or switch. See the ‘Electronic Dimmable Driver / Dimmer Compatibility List’ for compatible dimming controls. See the dimming control manufacturer
installation guide for complete wiring instructions.
6. Ensure to load the driver at least 60% of the labeled load for proper dimming performance (required for dimmable installations only).
7. Refer to driver or controller specications for a compatible junction box.
8. See xture specications for maximum series run limits.
Install applicable wire gauge / type
V+
V-
LED Tape Light / Fixture8
V+
V-
AC Power
50/60Hz
L
N
DIM- (White) DIM- (Gray)
N
L
Input
Output
V+
V-
Class 2, 0-10V Driver3
Class 2 Only.
Install applicable
gauge wire / type.
V+
V- V- (Black)
V+ (Red)
DIM+ (Blue) DIM+ (Purple)
0-10V
Dimmer / Control
to dimmerto load
Driver Line Hot (Brown)
L (Black) Dimmer Input Hot (Black)
GND
Dimmer Switched Hot (Red)
Driver Neutral
(Blue)
AC Power
50/60Hz
120VAC or 277VAC
Magnetic Low Voltage Dimmer1
V+ (Red)
V- (Blue)
LED Tape Light / Fixture8
LN
N (White)
L (Black)
Magnetic
Dimmable Driver2
Install applicable wire gauge / type
V+
V-
V+
V-
GND (Green)
Some dimmers may require an
additional neutral wire connection.
Table of contents
Popular Lantern manuals by other brands

Pro-Idee
Pro-Idee 650-853 quick guide

olympia electronics
olympia electronics GR-8/leds installation instructions

unios
unios Evio EVIO0907 manual

Visual Comfort & Co.
Visual Comfort & Co. Club Door Large Lantern Assembly instructions

BEGA
BEGA 24 182 Instructions for use

Home & Lighting
Home & Lighting 60W Solar Street Light 6000 Lumens instruction manual

ML Accessories
ML Accessories RW5WW Installation & maintenance manual

BEGA
BEGA 24 210 Instructions for use

Quoizel
Quoizel BERK8407MB installation guide

olympia electronics
olympia electronics SLD-28/DZ quick start guide

Metalumen
Metalumen Grande RM4D Series installation instructions

Solar Bollard Lighting
Solar Bollard Lighting SBL installation guide