LumaPro 39UU95 User manual

Please read and save these instructions. Read through this owner’s manual carefully before
using product. Protect yourself and others by observing all safety information, warnings, and
cautions. Failure to comply with instructions could result in personal injury and/or damage to
product or property. Please retain instructions for future reference.
Operating Instructions 39UU95, 39UU98, 39UV08
LED Large
Flood Lights
Description
An efficient, energy saving replacement for metal halide and high-pressure sodium fixtures,
containing an integral listed driver, the LED Large Flood Light fixtures can be easily
installed to a slip fitter.
Picture is for illustration purposes only. Your model may vary.
CONSTRUCTION
Fixture: The heavy duty cast aluminum one-piece housing is polyester powder coated and
sealed from dirt, water and insects with a hinged door with a shock-proof tempered glass.
Lens: Tempered Glass
LED Module: Copper plating provides high thermal transfer rate, minimizing the junction
temperature of the LEDs.
Finish: Dark bronze
Specifications and Dimensions
39UU95 120-277V 136W 5000K 12,140 70 7.5” x 16.5” x 16.5”
39UU98 120-277V 100W 5000K 9,160 70 7.5” x 16.5” x 16.5”
39UV08 120-277V 62W 5000K 5,470 70 7.5” x 16.5” x 16.5”
Dimensions (in)
Model Volts Watts CCT Lumens CRI H” x L” x D”

2
LumaPro Operating Instructions
39UU95, 39UU98, 39UV08
LED Large
Flood Lights
General Safety Information
• To reduce the risk of death, personal injury or property damage from fire, electric shock,
falling parts, cuts/abrasions, and other hazards read all warnings and instructions
included with and on the fixture box and all fixture labels.
• Before installing, servicing, or performing routine maintenance upon this equipment, follow
these general precautions.
• Commercial installation, service and maintenance of luminaires should be performed by a
qualified licensed electrician.
• For Residential installation: If you are unsure about the installation or maintenance of the
luminaires, consult a qualified licensed electrician and check your local electrical code.
• DO NOT INSTALL DAMAGED PRODUCT!
• This fixture is intended to be connected to a properly installed and grounded UL listed
junction box.
WARNING:
RISK OF ELECTRICALSHOCK
• Turn off electrical power at fuse or circuit breaker box before wiring fixture to the power
supply.
• Turn off the power when you perform any maintenance.
• Verify that supply voltage is correct by comparing it with the luminaire label information.
• Make all electrical and grounded connections in accordance with the National Electrical
Code and any applicable local code requirements.
• All wiring connections should be capped with UL approved wire connectors.
CAUTION:
RISK OF INJURY
• Wear gloves and safety glasses at all times when removing luminaire from carton,
installing, servicing or performing maintenance.
• Avoid direct eye exposure to the light source while it is on.
• Account for small parts and destroy packing material, as these may be hazardous to
children.
CAUTION:
RISK OF FIRE
• Keep combustible and other materials that can burn away from luminaire and lamp/lens.
• MIN 90°C SUPPLY CONDUCTORS.

3
LumaPro Operating Instructions
39UU95, 39UU98, 39UV08
LED Large
Flood Lights
Wiring Diagram
Connecting driver to AC source supply:
Operating Temp: -30 F to 120F
1. All units must be individually connected to
the AC supply (120-277 VAC):
Black = Line
White = Neutral
Green = Ground
2. Line connection to be made to switch
lead from source.
Installation Instructions
Before installation, ensure if power supply is disconnected. Cables must be connected in
accordance to instruction and proper standing rules.
1. The Flood Light Knuckle, tenon slip fitter, can be field modified to aim from -90 to +90
degrees.
2. With a Philips head screw driver, loosen and remove the cover plate for the junction box
in the knuckle. (Fig. 1)
3. With a 5/8’’ socket, loosen the bolt (do not remove) allowing for knuckle rotation if angled
mounting is desired.
4. Rotate the slip fit component of the knuckle to the desired angle relative to the LEDs.
5. Feed the power leads from the tenon through the knuckle. (Fig. 2)
6. With a 5/8’’ socket, tighten the bolt, locking the knuckle in place. Take care not to pinch
any wire when tightening the bolt.
7. Replace the junction box cover, taking care not to pinch any wires and that the O-ring is
positioned for proper sealing. Note, if electrical connections will be made in the junction
box, the cover may be temporarily left off.
8. With a 5/32’’ hex key, loosen (do not remove) the (2) set screws in the slip-fitter of
the knuckle as shown below.

4
LumaPro Operating Instructions
39UU95, 39UU98, 39UV08
LED Large
Flood Lights
Mounting of Area Light with Slip Fitter Arm
9. Place the slip fitter onto the tenon and point the
knuckle in the desired direction. Take care not
to pinch any wires in this process. (Fig. 3)
10. With a 5/32’’ hex key, tighten the (2) set screws
in the slip-fitter portion of the knuckle securing it
to the tenon.
11. Remove the two bolts from the knuckle
ensuring the gasket is not damaged in the
process.
12. It is suggested to have 2 members present
when mounting the fixture.
13. Unfasten the (4) screws with a Philips head
screw driver located on the door frame to the
fixture; enabling access to the interior of the
housing and mounting holes.
14. Feed the power leads from the tenon into
the fixture housing, and follow the provided
wiring instruction.
15. The gasket is then placed flush to the exterior
of the fixture housing, and the mounting plate is
placed flush to the interior of the housing while
maintaining clear access for the bolt. Fasten the
two mounting bolts, securing the knuckle to the fixture.
16. The entire installation order is depicted in Figure 4 to the right.
17. The fixture door is then fastened to the fixture housing ensuring a tight seal.
(Caution: Do not over tighten, creating small rips in the gasket)
18. The housing door is then closed completing the mounting of the fixture.
19. Enjoy your new LED Flood Light!
Warranty
LIMITED FIVE-YEAR WARRANTY
Should this product fail to perform satisfactorily due to a defect or poor workmanship within
FIVE YEAR from the date of purchase, return it to the place of purchase and it will be
replaced, and free of charge. Incidental or consequential damages are excluded from this
warranty.
Manufactured for Grainger International, Inc.
100 Grainger Pkwy., Lake Forest IL 60045 U.S.A.
This manual suits for next models