Lumascape PowerSync PS User manual

READ ALL SAFETY INSTRUCTIONS FIRST
›Follow all safety instructions carefully. Failure to do so will
void warranty.
›Ensure installation complies with local laws and any
applicable standards.
›Only use Lumascape power supply, control equipment and
leader cables.
›Ensure mains input power is surge protected.
›Never make connections whilst the power is connected.
›Do not make modifications or alter product.
›Keep luminaire clean and free of debris.
›Connectors are to be kept clean and dry at all times.
›Once installed, all connectors are to be mated and a
PowerSyncTM terminator is required on the last fitting of run.
LS6540
PowerSync™ PS Data Injector
Installation Instructions
ASIA PACIFIC 18 Brandl Street, Eight Mile Plains, QLD 4113, Australia P: +61 7 3854 5000 | F: +61 7 3854 5001 | E: sales@lumascape.com | www.lumacape.com.au
NORTH AMERICA 1940 Diamond Street, San Marcos, CA 94070, USA P: +1 650 595 5862 | F: +1 650 595 5820 | E: [email protected] | www.lumacape.com
IN0172 N191118

ASIA PACIFIC 18 Brandl Street, Eight Mile Plains, QLD 4113, Australia P: +61 7 3854 5000 | F: +61 7 3854 5001 | E: sales@lumascape.com | www.lumacape.com.au
NORTH AMERICA 1940 Diamond Street, San Marcos, CA 94070, USA P: +1 650 595 5862 | F: +1 650 595 5820 | E: [email protected] | www.lumacape.com
1 / 17IN0172 N191118
Products and specifications are subject to change without notice.
Table of Contents
LS6540
Product Overview ................................................................. 2
Mode Switch and Indicator Light Descriptions ........... 3
Wiring for DMX Controllers
International .................................................................... 4
North America ................................................................ 5
Wiring for 0-10 V Sinking Dimmers
International .................................................................... 6
North America .................................................................7
Wiring for Sourcing Dimmers
International .................................................................... 8
North America ................................................................ 9
Phase Dimming Calibration..............................................10
Wiring for Trailing Edge Phase Dimmers
International ....................................................................11
North America ...............................................................12
Testing Functions.................................................................13
Network Installation............................................................14
System Limitations ..............................................................15
PowerSync™ PS Data Injector
Installation Instructions

ASIA PACIFIC 18 Brandl Street, Eight Mile Plains, QLD 4113, Australia P: +61 7 3854 5000 | F: +61 7 3854 5001 | E: sales@lumascape.com | www.lumacape.com.au
NORTH AMERICA 1940 Diamond Street, San Marcos, CA 94070, USA P: +1 650 595 5862 | F: +1 650 595 5820 | E: [email protected] | www.lumacape.com
2 / 17 IN0172 N191118
Products and specifications are subject to change without notice.
PowerSync™ PS Data Injector
Installation Instructions
Product Overview
Lid Screws
Use Allen key to remove lid
screws and access the interior
of the PowerSyncTM enclosure.
Plug
Leave plug in place if not
required for cable entry.
Plug
Remove one plug for each required
cable entry and replace with suitable
cable gland or conduit adaptor.
Seal
If required, retain and use seal provided to
ensure a water tight seal between cable, gland
and encloure.
Electronic equipment inside. Failing to seal
enclosure properly will void warranty.
Mounting Holes
Use suitable screws (6mm or ¼") and flat washers to attach enclosure to
suitable mounting surface.
Observe orientation diagram in back of enclosure for correct orientation.
Enclosure should be mounted in a vertical orientation so that the cable
entries do not face upwards.
DANGER
ISOLATE DEVICE FROM POWER
Failure to isolate power
supply before installation or
maintenance may result in
fire, serious injury, electric
shock, death and may
damage the luminaire.
NO POWER
TOOLS
DO NOT USE SILICONE
ON OUTSIDE SURFACE
KEEP ELECTRONICS FREE
FROM DIRT AND MOISTURE
DO NOT HOSE OR
PRESSURE CLEAN
N653
LS6406
3 x PowerSync Terminator
LS6407
1 x DMX Terminator

ASIA PACIFIC 18 Brandl Street, Eight Mile Plains, QLD 4113, Australia P: +61 7 3854 5000 | F: +61 7 3854 5001 | E: sales@lumascape.com | www.lumacape.com.au
NORTH AMERICA 1940 Diamond Street, San Marcos, CA 94070, USA P: +1 650 595 5862 | F: +1 650 595 5820 | E: [email protected] | www.lumacape.com
3 / 17IN0172 N191118
Products and specifications are subject to change without notice.
Mode Switch and Indicator Light Descriptions
PowerSync™ PS Data Injector
Installation Instructions
Ferrules must be used
with stranded wire
Scale 1: 1
STRANDED ONLY
1.5–6.0 mm
2
15mm
16–8A WG
0.6"
LUMASCAPE
www.lumascape.com
Phase
control
Power in
Data
Power
PowerSync
PowerSync out
PWM/ 0–10V
Mode USB
Cat 5 (and similar) cable
termination according to
T568A colour scheme
Scale 1: 1
STRANDED/SOLID
0.2–1.5 mm
2
10mm
24–16 AWG
0.4"
Status
Check
Use with Lumascape wireless DMX
DMX in DMX out
GND
GND
Com
10V out
Ch 1 in
Ch 2 in
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
techsupport.lumascape.com
DMX Trac
L N L N
Mode Switch
Label Descriptions
0 DMX/RDM
1 DMX/RDM with Relay Control
2 TEST: All channels OFF
3 TEST: All channels ON
4 TEST: Cycle 4 Channels
5 0-10 V Dimming: Sourcing / PWM Dimming
6 0-10 V Dimming: Sinking / PWM Dimming: Inverted
7 Phase Dimming
8 USB
9 Reserved
10 DMX/RDM with SIP
11 Reserved
12 Reserved
13 Reserved
14 Erase Parameters
15 Reserved
Indicator Light
LED Indicator Event Appearance Note
Power Main Input Power Illuminates
PowerSync™ PowerSync™ output enabled Illuminates
Status
Start Up 3 flashes
Normal Operation 1 flash, every 5 seconds
Circuit Fault: Over Voltage 2 flashes, every 5 seconds
PowerSync™ Fault 4 flashes, every 5 seconds
Phase Dimming Calibration 3 flashes on calibration event See Phase Dimming
Erase Parameters 3 flashes on erase event See Phase Dimming
Check
Start Up On
Normal Operation O
Relay Open: Fault Detected On
Relay Open: Manual Override Flashing
USB USB Connected Illuminates / flashes with data
DMX Trac
DMX Trac Detected Flashing with DMX frames
Dimming Signal Detected 1-20 Hz flashing proportional to input level 0-10 V, PWM and Phase Dimming
Phase Dimming Locked Illuminates See Phase Dimming
QUESTIONS
Contact us at details below
LS6540

ASIA PACIFIC 18 Brandl Street, Eight Mile Plains, QLD 4113, Australia P: +61 7 3854 5000 | F: +61 7 3854 5001 | E: sales@lumascape.com | www.lumacape.com.au
NORTH AMERICA 1940 Diamond Street, San Marcos, CA 94070, USA P: +1 650 595 5862 | F: +1 650 595 5820 | E: [email protected] | www.lumacape.com
4 / 17 IN0172 N191118
Products and specifications are subject to change without notice.
PowerSync™ PS Data Injector
Installation Instructions
Wiring for DMX Controllers (International)
Mode Switch Set to Mode 0
DMX In
Colour T-568A Colour T-568B Label Designation
White / Brown White / Brown GND Ground
Green Orange − Data −
White / Green White / Orange + Data +
DMX Out to next PowerSync™ Data Injector
(optional)
Colour T-568A Colour T-568B Label Designation
Green Orange − Data −
White / Green White / Orange + Data +
White / Brown White / Brown GND Ground
Connect to DMX in terminals of next PowerSyncTM Data Injector for DMX
loop-through functionality.
NOTE: If the output is not used, either LS6407 DMX Terminator (included
with PowerSyncTM Injector) or a 120 Ω, 0.125 W resistor must be inserted
between Data + and Data − of the DMX out terminals.
Refer to third
party installation
instructions for details
on dimmer installation.
Power In (International)
Colour Label Designation
Blue N Neutral
Green / Yellow Earth
Brown L Live (110-240 V)
PowerSync™ Out to Luminaires
Colour Label Designation
Blue N Neutral
Green / Yellow Earth
Brown L Live (110-240 V)
Black* Data PowerSync™ Data
* Connecting high voltage to data terminal will cause
permanent damage and void warranty.
LUMASCAPE
www.lumascape.com
Power
PowerSync
Mode USB
Status
Check
Use with Lumascape wireless DMX
DMX in DMX out
GND
GND
Com
10V out
Ch 1 in
Ch 2 in
0
1
2
3
4
5
6
7
8
9
10
12
11
14
1
3
1
5
DMX Trac
techsupport.lumascape.com
At the end of the run, connect
the LS6407 DMX Terminator
between Data + and Data - of
the DMX out terminal in the
final PowerSyncTM Data Injector.
DMX Termination
PWM/ 0–10V
de USB
Cat 5 (and similar) cable
termination according to
T568A colour scheme
Use with Lumascape wireless DMX
DMX in DMX out
GND
GND
Com
10V out
Ch 1 in
Ch 2 in
1
2
3
4
5
6
7
DMX Trac
techsupport.lumascape.com
Label Description
0 DMX/RDM
1 DMX/RDM with Relay Control / Energy Saving
2 TEST: All Channels OFF
3 TEST: All Channels ON
4 TEST: Cycle 4 Channels
8 USB
Mode Switch Key
When there is no DMX
or the DMX level is 0 on all
channels for 15 minutes the
PowerSync™ will de-energise
the outgoing circuit.
MODE 1: DMX / RDM with
Relay Control / Energy Saving

ASIA PACIFIC 18 Brandl Street, Eight Mile Plains, QLD 4113, Australia P: +61 7 3854 5000 | F: +61 7 3854 5001 | E: sales@lumascape.com | www.lumacape.com.au
NORTH AMERICA 1940 Diamond Street, San Marcos, CA 94070, USA P: +1 650 595 5862 | F: +1 650 595 5820 | E: [email protected] | www.lumacape.com
5 / 17IN0172 N191118
Products and specifications are subject to change without notice.
Wiring for DMX Controllers (International)
LS6540
PowerSync™ PS Data Injector
Installation Instructions
Wiring for DMX Controllers (North America)
DMX Out to next PowerSync™ Data Injector
(optional)
Colour T-568A Colour T-568B Label Designation
Green Orange − Data −
White / Green White / Orange + Data +
White / Brown White / Brown GND Ground
Connect to DMX in terminals of next PowerSyncTM Data Injector for DMX
loop-through functionality.
NOTE: If the output is not used, either LS6407 DMX Terminator (included
with PowerSyncTM Injector) or a 120 Ω, 0.125 W resistor must be inserted
between Data + and Data − of the DMX out terminals.
DMX In
Colour T-568A Colour T-568B Label Designation
White / Brown White / Brown GND Ground
Green Orange − Data −
White / Green White / Orange + Data +
Refer to third
party installation
instructions for details
on dimmer installation.
At the end of the run, connect
the LS6407 DMX Terminator
between Data + and Data - of
the DMX out terminal in the
final PowerSyncTM Data Injector.
DMX Termination
PWM/ 0–10V
de USB
Cat 5 (and similar) cable
termination according to
T568A colour scheme
Use with Lumascape wireless DMX
DMX in DMX out
GND
GND
Com
10V out
Ch 1 in
Ch 2 in
1
2
3
4
5
6
7
DMX Trac
techsupport.lumascape.com
Mode Switch Set to Mode 0
LUMASCAPE
www.lumascape.com
Power
PowerSync
Mode USB
Status
Check
Use with Lumascape wireless DMX
DMX in DMX out
GND
GND
Com
10V out
Ch 1 in
Ch 2 in
0
1
2
3
4
5
6
7
8
9
10
12
11
14
1
3
1
5
DMX Trac
techsupport.lumascape.com
Power In
Colour Label Designation
White N Neutral
Green / Yellow Earth
Black L Live (120-277 V)
PowerSync™ Out to Luminaires
Colour Label Designation
White N Neutral
Green / Yellow Earth
Black L Live (120-277 V)
Grey* Data PowerSync™ Data
* Connecting high voltage to data terminal will cause
permanent damage and void warranty.
Label Description
0 DMX/RDM
1 DMX/RDM with Relay Control / Energy Saving
2 TEST: All Channels OFF
3 TEST: All Channels ON
4 TEST: Cycle 4 Channels
8 USB
Mode Switch Key
When there is no DMX
or the DMX level is 0 on all
channels for 15 minutes the
PowerSync™ will de-energise
the outgoing circuit.
MODE 1: DMX / RDM with
Relay Control / Energy Saving

ASIA PACIFIC 18 Brandl Street, Eight Mile Plains, QLD 4113, Australia P: +61 7 3854 5000 | F: +61 7 3854 5001 | E: sales@lumascape.com | www.lumacape.com.au
NORTH AMERICA 1940 Diamond Street, San Marcos, CA 94070, USA P: +1 650 595 5862 | F: +1 650 595 5820 | E: [email protected] | www.lumacape.com
6 / 17 IN0172 N191118
Products and specifications are subject to change without notice.
LUMASCAPE
www.lumascape.com
Power
PowerSync
Mode USB
Status
Check
Use with Lumascape wireless DMX
DMX in DMX out
GND
GND
Com
10V out
Ch 1 in
Ch 2 in
0
1
2
3
4
5
6
7
8
9
10
12
11
14
1
3
1
5
DMX Trac
techsupport.lumascape.com
Wiring for 0-10 V Sinking Dimmers (International)
Refer to third party installation
instructions for details on
dimmer installation.
Mode Switch Set to Mode 6.
DMX Out to next PowerSync™ Data Injector
(optional)
Colour T-568A Colour T-568B Label Designation
Green Orange − Data −
White / Green White / Orange + Data +
White / Brown White / Brown GND Ground
Connect to DMX in terminals of next PowerSyncTM Data Injector
for DMX loop-through functionality.
Power In
Colour Label Designation
Blue N Neutral
Green / Yellow Earth
Brown L Live (110-240 V)
PowerSync™ Out to Luminaires
Colour Label Designation
Blue N Neutral
Green / Yellow Earth
Brown L Live (110-240 V)
Black* Data PowerSync™ Data
* Connecting high voltage to data terminal will cause
permanent damage and void warranty.
0-10 V In from sinking dimmer
Colour Label Designation
Grey Ch 2 In Channel 2 return (optional)
Grey Ch 1 In Channel 1 return
Purple 10 V Out 10 V source
Please Note:
Attached luminaires need to be configured as
single channel, DMX address (Channel 1 In Only)
or Tuneable White (Channel 1 In & Channel 2 In).
!
PowerSync™ PS Data Injector
Installation Instructions
Label Description
5 0-10 V Dimming: Sourcing / PWM Dimming
6 0-10 V Dimming: Sinking / PWM Dimming: Inverted
2 TEST: All Channels OFF
3 TEST: All Channels ON
4 TEST: Cycle 4 Channels
8 USB
Mode Switch Key
NOTE: 0-10 V level is digitized and
passed out as DMX.

ASIA PACIFIC 18 Brandl Street, Eight Mile Plains, QLD 4113, Australia P: +61 7 3854 5000 | F: +61 7 3854 5001 | E: sales@lumascape.com | www.lumacape.com.au
NORTH AMERICA 1940 Diamond Street, San Marcos, CA 94070, USA P: +1 650 595 5862 | F: +1 650 595 5820 | E: [email protected] | www.lumacape.com
7 / 17IN0172 N191118
Products and specifications are subject to change without notice.
Label Description
5 0-10 V Dimming: Sourcing / PWM Dimming
6 0-10 V Dimming: Sinking / PWM Dimming: Inverted
2 TEST: All Channels OFF
3 TEST: All Channels ON
4 TEST: Cycle 4 Channels
8 USB
Mode Switch Key
LUMASCAPE
www.lumascape.com
Power
PowerSync
Mode USB
Status
Check
Use with Lumascape wireless DMX
DMX in DMX out
GND
GND
Com
10V out
Ch 1 in
Ch 2 in
0
1
2
3
4
5
6
7
8
9
10
12
11
14
1
3
1
5
DMX Trac
techsupport.lumascape.com
Wiring for 0-10 V Sinking Dimmers (North America)
Mode Switch Set to Mode 6.
Power In
Colour Label Designation
White N Neutral
Green / Yellow Earth
Black L Live (120-277 V)
PowerSync™ Out to Luminaires
Colour Label Designation
White N Neutral
Green / Yellow Earth
Black L Live (120-277 V)
Grey* Data PowerSync™ Data
* Connecting high voltage to data terminal will cause
permanent damage and void warranty.
0-10 V In from sinking dimmer
Colour Label Designation
Grey Ch 2 In Channel 2 return (optional)
Grey Ch 1 In Channel 1 return
Purple 10 V Out 10 V source
Please Note:
Attached luminaires need to be configured as
single channel, DMX address (Channel 1 In Only)
or Tuneable White (Channel 1 In & Channel 2 In).
!
PowerSync™ PS Data Injector
Installation Instructions
DMX Out to next PowerSync™ Data Injector
(optional)
Colour T-568A Colour T-568B Label Designation
Green Orange − Data −
White / Green White / Orange + Data +
White / Brown White / Brown GND Ground
Connect to DMX in terminals of next PowerSyncTM Data Injector for DMX
loop-through functionality.
Refer to third party installation
instructions for details on
dimmer installation.
NOTE: 0-10 V level is digitized and
passed out as DMX.
LS6540

ASIA PACIFIC 18 Brandl Street, Eight Mile Plains, QLD 4113, Australia P: +61 7 3854 5000 | F: +61 7 3854 5001 | E: sales@lumascape.com | www.lumacape.com.au
NORTH AMERICA 1940 Diamond Street, San Marcos, CA 94070, USA P: +1 650 595 5862 | F: +1 650 595 5820 | E: [email protected] | www.lumacape.com
8 / 17 IN0172 N191118
Products and specifications are subject to change without notice.
LUMASCAPE
www.lumascape.com
Power
PowerSync
Mode USB
Status
Check
Use with Lumascape wireless DMX
DMX in DMX out
GND
GND
Com
10V out
Ch 1 in
Ch 2 in
0
1
2
3
4
5
6
7
8
9
10
12
11
14
1
3
1
5
DMX Trac
techsupport.lumascape.com
Wiring for 0-10 V Sourcing Dimmers (International)
Mode Switch Set to Mode 5.
Power In
Colour Label Designation
Blue N Neutral
Green / Yellow Earth
Brown L Live (110-240 V)
PowerSync™ Out to Luminaires
Colour Label Designation
Blue N Neutral
Green / Yellow Earth
Brown L Live (110-240 V)
Black* Data PowerSync™ Data
* Connecting high voltage to data terminal will cause
permanent damage and void warranty.
0-10 V In from sourcing dimmer
Label Designation
Com Common –
Ch 2 In Channel 2 + (optional)
Ch 1 In Channel 1 +
Please Note:
Attached luminaires need to be configured as
single channel, DMX address (Channel 1 In Only)
or Tuneable White (Channel 1 In & Channel 2 In).
!
PowerSync™ PS Data Injector
Installation Instructions
DMX Out to next PowerSync™ Data Injector
(optional)
Colour T-568A Colour T-568B Label Designation
Green Orange − Data −
White / Green White / Orange + Data +
White / Brown White / Brown GND Ground
Connect to DMX in terminals of next PowerSyncTM Data Injector
for DMX loop-through functionality.
Refer to third party installation
instructions for details on
dimmer installation.
Label Description
5 0-10 V Dimming: Sourcing / PWM Dimming
6 0-10 V Dimming: Sinking / PWM Dimming: Inverted
2 TEST: All Channels OFF
3 TEST: All Channels ON
4 TEST: Cycle 4 Channels
8 USB
Mode Switch Key
NOTE: 0-10 V level is digitized and
passed out as DMX.

ASIA PACIFIC 18 Brandl Street, Eight Mile Plains, QLD 4113, Australia P: +61 7 3854 5000 | F: +61 7 3854 5001 | E: sales@lumascape.com | www.lumacape.com.au
NORTH AMERICA 1940 Diamond Street, San Marcos, CA 94070, USA P: +1 650 595 5862 | F: +1 650 595 5820 | E: [email protected] | www.lumacape.com
9 / 17IN0172 N191118
Products and specifications are subject to change without notice.
PowerSync™ PS Data Injector
Installation Instructions
LUMASCAPE
www.lumascape.com
Power
PowerSync
Mode USB
Status
Check
Use with Lumascape wireless DMX
DMX in DMX out
GND
GND
Com
10V out
Ch 1 in
Ch 2 in
0
1
2
3
4
5
6
7
8
9
10
12
11
14
1
3
1
5
DMX Trac
techsupport.lumascape.com
Wiring for 0-10 V Sourcing Dimmers (North America)
Mode Switch Set to Mode 5.
Power In
Colour Label Designation
White N Neutral
Green / Yellow Earth
Black L Live (120-277 V)
PowerSync™ Out to Luminaires
Colour Label Designation
White N Neutral
Green / Yellow Earth
Black L Live (120-277 V)
Grey* Data PowerSync™ Data
* Connecting high voltage to data terminal will cause
permanent damage and void warranty.
0-10 V In from sourcing dimmer
Label Designation
Com Common –
Ch 2 In Channel 2 + (optional)
Ch 1 In Channel 1 +
Please Note:
Attached luminaires need to be configured as
single channel, DMX address (Channel 1 In Only)
or Tuneable White (Channel 1 In & Channel 2 In).
!
DMX Out to next PowerSync™ Data Injector
(optional)
Colour T-568A Colour T-568B Label Designation
Green Orange − Data −
White / Green White / Orange + Data +
White / Brown White / Brown GND Ground
Connect to DMX in terminals of next PowerSyncTM Data Injector for DMX
loop-through functionality.
Refer to third party installation
instructions for details on
dimmer installation.
Label Description
5 0-10 V Dimming: Sourcing / PWM Dimming
6 0-10 V Dimming: Sinking / PWM Dimming: Inverted
2 TEST: All Channels OFF
3 TEST: All Channels ON
4 TEST: Cycle 4 Channels
8 USB
Mode Switch Key
NOTE: 0-10 V level is digitized and
passed out as DMX.
LS6540

ASIA PACIFIC 18 Brandl Street, Eight Mile Plains, QLD 4113, Australia P: +61 7 3854 5000 | F: +61 7 3854 5001 | E: sales@lumascape.com | www.lumacape.com.au
NORTH AMERICA 1940 Diamond Street, San Marcos, CA 94070, USA P: +1 650 595 5862 | F: +1 650 595 5820 | E: [email protected] | www.lumacape.com
10 / 17 IN0172 N191118
Products and specifications are subject to change without notice.
Phase Dimming Calibration Procedure
PowerSync™ PS Data Injector
Installation Instructions
Phase dimming calibration for proper operation
To account for variability across phase dimming controllers, the
LS6540 unit is shipped with a low default maximum brightness
input level.
When a new phase dimming controller is connected
• Unit automatically calibrates to any new maximum input levels
• Simply set the controller to its maximum setting and leave for 10-15 seconds (whilst in mode switch position 7)
After 30-35 Seconds
• “Status” indicator will flash 3 times in quick succession.
• Previous stored calibration data has now been erased.
• Unit can be re-calibrated with a new controller
Line Voltage Fluctuations
• The LS6540 will enter locked mode after one (1) minute with no change in input level.
• A slighting larger than usual change in controller input is required to change light output.
• As soon as this change is detected, normal operation resumes with fine grained control possible.
DMX Trac Indicator
• If illuminated but not flashing controller and controller change does not appear to change light output
• Keep adjusting controller until DMX trac indicator starts flashing and luminaires respond to input changes.
When auto calibration is complete
• “Status” indicator will flash 3 times in quick succession.
• Control is now responsive over entire input range.
• If unit has been previously calibrate and controller needs to be change the previous auto calibration level can be erased by placing the
unit in mode switch position 14 and power cycling the LS6540.

ASIA PACIFIC 18 Brandl Street, Eight Mile Plains, QLD 4113, Australia P: +61 7 3854 5000 | F: +61 7 3854 5001 | E: sales@lumascape.com | www.lumacape.com.au
NORTH AMERICA 1940 Diamond Street, San Marcos, CA 94070, USA P: +1 650 595 5862 | F: +1 650 595 5820 | E: [email protected] | www.lumacape.com
11 / 17IN0172 N191118
Products and specifications are subject to change without notice.
LUMASCAPE
www.lumascape.com
Power
PowerSync
Mode USB
Status
Check
Use with Lumascape wireless DMX
DMX in DMX out
GND
GND
Com
10V out
Ch 1 in
Ch 2 in
0
1
2
3
4
5
6
7
8
9
10
12
11
14
1
3
1
5
DMX Trac
techsupport.lumascape.com
Wiring for Trailing Edge Phase Dimmers (International)
Mode Switch Set to Mode 7.
Power In
Colour Label Designation
Blue N Neutral
Green / Yellow Earth
Brown L Live (110-240 V)
PowerSync™ Out to Luminaires
Colour Label Designation
Blue N Neutral
Green / Yellow Earth
Brown L Live (110-240 V)
Black* Data PowerSync™ Data
* Connecting high voltage to data terminal will cause
permanent damage and void warranty.
PowerSync™ PS Data Injector
Installation Instructions
Refer to third party
installation instructions
for details on dimmer
installation.
Refer to third party
installation instructions
for details on dimmer
installation.
Signal In from Trailing
Edge Phase Dimmer
Label Designation
Live Input
Signal Input
DMX Out to next PowerSync™ Data Injector
(optional)
Colour T-568A Colour T-568B Label Designation
Green Orange − Data −
White / Green White / Orange + Data +
White / Brown White / Brown GND Ground
Connect to DMX in terminals of next PowerSyncTM Data Injector for DMX
loop-through functionality.
LS6540
Label Description
7 Phase Dimming
2 TEST: All Channels OFF
3 TEST: All Channels ON
4 TEST: Cycle 4 Channels
8 USB
Mode Switch Key

ASIA PACIFIC 18 Brandl Street, Eight Mile Plains, QLD 4113, Australia P: +61 7 3854 5000 | F: +61 7 3854 5001 | E: sales@lumascape.com | www.lumacape.com.au
NORTH AMERICA 1940 Diamond Street, San Marcos, CA 94070, USA P: +1 650 595 5862 | F: +1 650 595 5820 | E: [email protected] | www.lumacape.com
12 / 17 IN0172 N191118
Products and specifications are subject to change without notice.
LUMASCAPE
www.lumascape.com
Power
PowerSync
Mode USB
Status
Check
Use with Lumascape wireless DMX
DMX in DMX out
GND
GND
Com
10V out
Ch 1 in
Ch 2 in
0
1
2
3
4
5
6
7
8
9
10
12
11
14
1
3
1
5
DMX Trac
techsupport.lumascape.com
Wiring for Trailing Edge Phase Dimmers (North America)
Mode Switch Set to Mode 7.
Power In
Colour Label Designation
White N Neutral
Green / Yellow Earth
Black L Live (120-277 V)
PowerSync™ Out to Luminaires
Colour Label Designation
White N Neutral
Green / Yellow Earth
Brown L Live (120-277 V)
Black* Data PowerSync™ Data
* Connecting high voltage to data terminal will cause
permanent damage and void warranty.
PowerSync™ PS Data Injector
Installation Instructions
Refer to third party
installation instructions
for details on dimmer
installation.
Signal In from Trailing
Edge Phase Dimmer
Label Designation
Live Input
Signal Input
DMX Out to next PowerSync™ Data Injector
(optional)
Colour T-568A Colour T-568B Label Designation
Green Orange − Data −
White / Green White / Orange + Data +
White / Brown White / Brown GND Ground
Connect to DMX in terminals of next PowerSyncTM Data Injector
for DMX loop-through functionality.
Label Description
7 Phase Dimming
2 TEST: All Channels OFF
3 TEST: All Channels ON
4 TEST: Cycle 4 Channels
8 USB
Mode Switch Key

ASIA PACIFIC 18 Brandl Street, Eight Mile Plains, QLD 4113, Australia P: +61 7 3854 5000 | F: +61 7 3854 5001 | E: sales@lumascape.com | www.lumacape.com.au
NORTH AMERICA 1940 Diamond Street, San Marcos, CA 94070, USA P: +1 650 595 5862 | F: +1 650 595 5820 | E: [email protected] | www.lumacape.com
13 / 17IN0172 N191118
Products and specifications are subject to change without notice.
To assist with installation, the LS6540 provides three (3) test modes
for PowerSync™ luminaires. These require only connected luminaires
and power, and no connected input signal.
If an input signal is connected, the LS6540 will not respond to this
signal in any of the modes below.
NOTE: These test signals apply to the relevant unit’s PowerSync™
output only –– it will not be passed through on the DMX / RDM
connectors if multiple LS6540 units are connected.
Testing Functions
PowerSync™ PS Data Injector
Installation Instructions
Mode Switch Position Output
2 Turn o all channels on all connected luminaires.
3 Turn on all channels on all connected luminaires to full brightness
4 Cycle channels 1-4 (and multiples thereof) on all connected luminaires at full brightness
LS6540

ASIA PACIFIC 18 Brandl Street, Eight Mile Plains, QLD 4113, Australia P: +61 7 3854 5000 | F: +61 7 3854 5001 | E: sales@lumascape.com | www.lumacape.com.au
NORTH AMERICA 1940 Diamond Street, San Marcos, CA 94070, USA P: +1 650 595 5862 | F: +1 650 595 5820 | E: [email protected] | www.lumacape.com
14 / 17 IN0172 N191118
Products and specifications are subject to change without notice.
Network Installations
Network Topology - PowerSync™ Dimmable
Up to 45 luminaires per run under the following conditions:
• Max total cable run length 150m (492’) in up to two trunk cables
• For run lengths in excess of 30m (100’), the data wire gauge cannot exceed 12-14 AWG (2.5mm2)
• For run lengths up to 30m (100’), the data wire gauge is not governed
• Refer to ‘Maximum Circuit Load’ table for circuit limitations
• Always observe local electrical codes for branch circuit current limitations
Terminator
Use PowerSync™ terminator, supplied
with leader cable to terminate last
luminaire in chain.
T
Maximum Current
≤16.0A through LS6540 Data Injector.
I
Connection Type
Circuits can be configured as either
connectorised or hardwired. For details
consult installation instructions and comply
with local electrical codes.
Control Signal
120-277V
50/60Hz
120-277V
50/60Hz
Loop to next PowerSync™
Data Injector
150m (492') max
Combined length of both trunk cables can not exceed 150m (492')
PowerSync™ Topology 1 - Single Trunk Cable
10m (33')max
PowerSync™ Topology 2 - Split Trunk Cable
LS6540
PowerSync™
Data Injector
LS6540
PowerSync™
Data Injector
I
I
T
1.8 m (6’) max
T
1.8 m (6’) max
T
1.8 m (6’) max
PowerSync™ PS Data Injector
Installation Instructions
PLEASE CHECK LUMINAIRE DATASHEETS FOR CIRCUIT LOADING AND ELECTRICAL LIMITATIONS.

ASIA PACIFIC 18 Brandl Street, Eight Mile Plains, QLD 4113, Australia P: +61 7 3854 5000 | F: +61 7 3854 5001 | E: sales@lumascape.com | www.lumacape.com.au
NORTH AMERICA 1940 Diamond Street, San Marcos, CA 94070, USA P: +1 650 595 5862 | F: +1 650 595 5820 | E: [email protected] | www.lumacape.com
15 / 17IN0172 N191118
Products and specifications are subject to change without notice.
Network Installations
Junction Box Terminator
LS6406
Fit LS6406 PowerSync™
Terminator between
earth and data wires. 3 x
PowerSync™ terminators
have been supplied with the
LS6540 PowerSync
TM
Data
Injector for this purpose.
Network Installations
PowerSync™ PS Data Injector
Installation Instructions
International
To Lumascape luminaire
Trunk cable and junction box supplied by others.
From
PowerSync™
Data Injector
To Lumascape luminaire
Trunk cable and junction box supplied by others.
From
PowerSync™
Data Injector
Active – Brown
Neutral – Blue
Data – Orange / Yellow
Earth – Green / Yellow
Active – Brown
Neutral – Blue
Data – Orange / Yellow
Earth – Green / Yellow
T
Terminator
Junction Box
Fit LS6406 PowerSync™
Terminator between
earth and data wires. 3 x
PowerSync™ terminators
have been supplied with the
LS6540 PowerSync
TM
Data
Injector for this purpose.
LS6406
North America
Active – Black Active – Black
To Lumascape luminaire To Lumascape luminaire
Trunk cable and junction box supplied by others. Trunk cable and junction box supplied by others.
From
PowerSync™
Data Injector
From
PowerSync™
Data Injector
Neutral – White Neutral – White
Data – Grey Data – Grey
Earth – Green / Yellow Earth – Green / Yellow
T
Please Note: The above diagrams are intended to show electrical pathways between
luminaires and ancillary device. These diagrams are not intended to show type or colour
of cord / wire, luminaire input voltage rating, wire gauge or approved use of the cord / wire
supplied with luminaires.
LS6540

ASIA PACIFIC
Brisbane Technology Park
18 Brandl Street, Eight Mile Plains
Queensland, 4113, Australia
P: +61 7 3854 5000
F: +61 7 3854 5001
NORTH AMERICA
1940 Diamond Street, San Marcos
California, 94070 United states
P: +1 650 595 5862
F: +1 650 595 5820
CHINA
20 West Building 377 Wuyi Road
Wujin Hi-Tech Zone, Changzhou
Jiangsu, China
P: +86 519 8919 2555
F: +86 519 8919 1053
MIDDLE EAST, NORTH AFRICA, INDIA, TURKEY
Dubai World Central
Building Block C, Oce #432
Dubai, United Arab Emirates
P: +97 4887 9951 or +97 1 54300 0421
F: +971 4887 9601
www.lumascape.com
FOLLOW US
Table of contents
Popular Laboratory Equipment manuals by other brands

Steril-Aire
Steril-Aire DE 422 Panel Installation and operation instruction

Klein Tools
Klein Tools TI220 instruction manual

C-Tech
C-Tech HYLN-5 product manual

V&P Scientific
V&P Scientific 418SV2-2x4-50CB-CC operating instructions

Steinberg Systems
Steinberg Systems SBS-LZ-2000SLS user manual

Metrohm
Metrohm 806 manual