ASIA PACIFIC 18 Brandl Street, Eight Mile Plains, QLD 4113, Australia P: +61 7 3854 5000 | F: +61 7 3854 5001 | E: sales@lumascape.com | www.lumacape.com.au
NORTH
AMERICA
1940 Diamond Street, San Marcos, CA 94070, USA P: +1 650 595 5862 | F: +1 650 595 5820 | E: [email protected] | www.lumacape.com5 / 17IN0172 N191118
Products and specifications are subject to change without notice.
Wiring for DMX Controllers (International)
LS6540
PowerSync™ PS Data Injector
Installation Instructions
Wiring for DMX Controllers (North America)
DMX Out to next PowerSync™ Data Injector
(optional)
Colour T-568A Colour T-568B Label Designation
Green Orange − Data −
White / Green White / Orange + Data +
White / Brown White / Brown GND Ground
Connect to DMX in terminals of next PowerSyncTM Data Injector for DMX
loop-through functionality.
NOTE: If the output is not used, either LS6407 DMX Terminator (included
with PowerSyncTM Injector) or a 120 Ω, 0.125 W resistor must be inserted
between Data + and Data − of the DMX out terminals.
DMX In
Colour T-568A Colour T-568B Label Designation
White / Brown White / Brown GND Ground
Green Orange − Data −
White / Green White / Orange + Data +
Refer to third
party installation
instructions for details
on dimmer installation.
At the end of the run, connect
the LS6407 DMX Terminator
between Data + and Data - of
the DMX out terminal in the
final PowerSyncTM Data Injector.
DMX Termination
PWM/ 0–10V
de USB
Cat 5 (and similar) cable
termination according to
T568A colour scheme
Use with Lumascape wireless DMX
DMX in DMX out
GND
GND
Com
10V out
Ch 1 in
Ch 2 in
1
2
3
4
5
6
7
DMX Trac
techsupport.lumascape.com
Mode Switch Set to Mode 0
LUMASCAPE
www.lumascape.com
Power
PowerSync
Mode USB
Status
Check
Use with Lumascape wireless DMX
DMX in DMX out
GND
GND
Com
10V out
Ch 1 in
Ch 2 in
0
1
2
3
4
5
6
7
8
9
10
12
11
14
1
3
1
5
DMX Trac
techsupport.lumascape.com
Power In
Colour Label Designation
White N Neutral
Green / Yellow Earth
Black L Live (120-277 V)
PowerSync™ Out to Luminaires
Colour Label Designation
White N Neutral
Green / Yellow Earth
Black L Live (120-277 V)
Grey* Data PowerSync™ Data
* Connecting high voltage to data terminal will cause
permanent damage and void warranty.
Label Description
0 DMX/RDM
1 DMX/RDM with Relay Control / Energy Saving
2 TEST: All Channels OFF
3 TEST: All Channels ON
4 TEST: Cycle 4 Channels
8 USB
Mode Switch Key
When there is no DMX
or the DMX level is 0 on all
channels for 15 minutes the
PowerSync™ will de-energise
the outgoing circuit.
MODE 1: DMX / RDM with
Relay Control / Energy Saving