Range testing.
Do not fit the wall switch or receiver permanently in position until a range test has been successfully completed. With
the temporary battery still connected place the receiver in the position where you want it to be.
Now take the wall transmitter or key fob to the place where it is to be used. With a wall switch, hold it against the wall and
operate the switch. Now go to the receiver and check that the ON/OFF LED has changed state. It is easier if you have help
during this procedure.
Repeat this test until you are satisfied that the system works 100% and then fit the units permanently as follows.
Fixing and wiring.
All wiring must be in compliance with IEE regulations. If in doubt you should consult a qualified electrician.
Remove the temporary battery and screw the receiver to the wall by inserting two no8 3/4” screws into the fixing holes.
The receiver must be fitted vertically with the aerial at the top and the cable glands at the bottom.
Pass a mains supply three core cable through one gland and tighten to provide anchorage and weather resistance.
1.
Connect the Brown cable to terminal LINE IN and the blue to terminalNEUTRAL.
2.
Pass the lamp load three core cable through the left hand gland and connect the Brown wire to terminalNO.
3.
Connect the Blue wire together with the first black wire to terminal NEUTRAL.
4.
Connect a loop or Brown wire to the LINE IN terminal and Cterminal.
5.
Both earth wires Green and Yellow must be joined together and insulated. The Earth wires DO NOT connect in
the receiver but simply loop through. See Fig 1.
The product must be supplied via a 6 Amp breaker or fuse.
This receiver is intended to operate lighting up to 1000 watts and small load electrical appliances such as pond pumps, electric
gates and doors etc.
WARNING: The components in this product are LIVE. Replace the cover before applying mains power.
Mode selection.
The receiver has three modes to choose from and these are selected by inserting or removing a link as shown on the diagram.
Double Mode is for multi switch operation or two way switching. In this mode it does not matter which position the switch is in.
Any switch which is operated will reverse the action of the previous switch.
Single Mode is for single switch operation. In this mode with the switch ON the light will be ON.
Mimic Mode is used for momentary contact closure as required for operating garage doors, electric blinds etc. When the button
on the key fob is pressed, the relay contacts will close and when the button is released the contacts will open.
Lamp load
1000Watts
Aerial.
To achieve the best range results you will need to fit the receiver where it has the least amount of obstacles between it and the
transmitter. The aerial must be vertical as shown and the higher the receiver is placed above ground level the greater the
range will be. The same applies to the transmitter. Do not fit the receiver on or in metal objects as this will seriously affect
range. Keep cables away from the aerial. With a clear line of site and with both the transmitter and receiver at 2 meters high
transmission ranges of 250 meters and beyond are possible. For greater ranges it is necessary to use special aerials on the
transmitter and receiver. See the web site or contact us directly for further details.