Luminite Easyswitch ESR-1 User manual

1
ESR-1
Easyswitch MAINS ON/OFF RECEIVER
Installation and operating instructions
FORWARD
Please read and understand the information in this manual.
If you do not understand or are unsure how to install this product, please consult a qualified
electrician.
Please note: Where the equilateral triangle is present, observe
and understand the information before proceeding. Again if in
doubt consult with a qualified electrician.
Thank you for purchasing from the Luminite Easyswitch range. Please follow the
instructions closely.
The ESR-1 wireless receiver is a Mains Voltage ON/OFF switch housed in a weather
proof enclosure.
The 1000 Watt switch capacity means you can operate a variety of loads such
as pumps, motors, lighting and much more. Range testing and code learning
is all done using a temporary battery and there is no need to connect to the
mains at this stage.
Each wall switch (EST-1) and key fob (ESF-1) has a unique code which may be
learnt by the receiver.
WARNING
Learning the switch code.
Do this before connecting the mains powerfor safety. You will need a PP3 9 Voltbattery.
NOTE: DO NOT CONNECT ANY PART OF THIS TO THE MAINS SUPPLY UNTIL STEPS 1 TO 7 HAVE BEEN COMPLETED.
STEP1. Screw the aerial provided to the screw fitting at the top of the receiver enclosure.
STEP2. Connect a standard PP3 9 Volt battery (not supplied) to the clipprovided.
The LEARN led will flash three times indicating correct operation.
STEP3. Press the LEARN button. The learn LED willlight.
STEP4. Operate the wall switch or keyfob button which is to work with this receiver.
The learn LED will flash and go out indicating that the code has been learnt.
Operate the switch again and observe the ON/OFFLED.
STEP5. Carry out rangetesting. (See Range testing on the next page)
STEP6. Remove battery and lead from screw terminals and fix the receiver permanently in position.
STEP7. Connect to the mains and replace cover.

2
Range testing.
Do not fit the wall switch or receiver permanently in position until a range test has been successfully completed. With
the temporary battery still connected place the receiver in the position where you want it to be.
Now take the wall transmitter or key fob to the place where it is to be used. With a wall switch, hold it against the wall and
operate the switch. Now go to the receiver and check that the ON/OFF LED has changed state. It is easier if you have help
during this procedure.
Repeat this test until you are satisfied that the system works 100% and then fit the units permanently as follows.
Fixing and wiring.
All wiring must be in compliance with IEE regulations. If in doubt you should consult a qualified electrician.
Remove the temporary battery and screw the receiver to the wall by inserting two no8 3/4” screws into the fixing holes.
The receiver must be fitted vertically with the aerial at the top and the cable glands at the bottom.
Pass a mains supply three core cable through one gland and tighten to provide anchorage and weather resistance.
1.
Connect the Brown cable to terminal LINE IN and the blue to terminalNEUTRAL.
2.
Pass the lamp load three core cable through the left hand gland and connect the Brown wire to terminalNO.
3.
Connect the Blue wire together with the first black wire to terminal NEUTRAL.
4.
Connect a loop or Brown wire to the LINE IN terminal and Cterminal.
5.
Both earth wires Green and Yellow must be joined together and insulated. The Earth wires DO NOT connect in
the receiver but simply loop through. See Fig 1.
The product must be supplied via a 6 Amp breaker or fuse.
This receiver is intended to operate lighting up to 1000 watts and small load electrical appliances such as pond pumps, electric
gates and doors etc.
WARNING: The components in this product are LIVE. Replace the cover before applying mains power.
Mode selection.
The receiver has three modes to choose from and these are selected by inserting or removing a link as shown on the diagram.
Double Mode is for multi switch operation or two way switching. In this mode it does not matter which position the switch is in.
Any switch which is operated will reverse the action of the previous switch.
Single Mode is for single switch operation. In this mode with the switch ON the light will be ON.
Mimic Mode is used for momentary contact closure as required for operating garage doors, electric blinds etc. When the button
on the key fob is pressed, the relay contacts will close and when the button is released the contacts will open.
Lamp load
1000Watts
Aerial.
To achieve the best range results you will need to fit the receiver where it has the least amount of obstacles between it and the
transmitter. The aerial must be vertical as shown and the higher the receiver is placed above ground level the greater the
range will be. The same applies to the transmitter. Do not fit the receiver on or in metal objects as this will seriously affect
range. Keep cables away from the aerial. With a clear line of site and with both the transmitter and receiver at 2 meters high
transmission ranges of 250 meters and beyond are possible. For greater ranges it is necessary to use special aerials on the
transmitter and receiver. See the web site or contact us directly for further details.

3
Set-up notes.
1.
The battery is not required after range testing has been completed. The battery lead MUST be unscrewed from the
terminals and removed.
2.
The receiver can learn up to 16 switches and/or keyfobs
3.
The receiver will retain the learned codes even if the power is removed
4.
To flush the memory, simply press and hold the learn button until the LED goes off. This takes about 5seconds.
5.
The ON/OFF LED mimics the switch action. This is especially useful when range testing with a battery.
Regulations
Electromagnetic Compatibility (EMC)
This equipment generates radiated radio frequency energy, if not installed and used in accordance with the instructions, it may
cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user should take the following measures: Re-orient or relocate the
receiving antenna. Increase the separation between the equipment and receiver.
WEEE Directive
The European Union has enacted a Directive 2012/19/EU on Waste Electrical and Electronic Equipment (WEEE Directive).
This directive is applicable in the European Union member states. The WEEE marking on this product (see above) or its
documentation indicates that the product must not be disposed of together with household waste. To prevent possible harm to
human health and/or the environment, the product must be disposed of in an approved and environmentally safe recycling
process. For further information on how to dispose of this product correctly, contact the product supplier, or the local authority
responsible for waste disposal in your area. Business users should contact the product supplier for information on how to
dispose of this product correctly. This product should not be mixed with other commercial waste.
Technical data:
Operating voltage 220-240V @ 50Hz
Max lamp load 1000 watts resistive. 500 watts
inductive
Switch current 5 amps @ 240 volts
Temperature range -10 to +40C
Enclosure IP66 Polycarbonate
Standards BS EN 60669
TECHNICAL HELPLINE 020
8361 5255
Luminite Electronics Ltd
2a Bellevue Road, Friern Barnet, London N11 3ER.
Phone: +44 (0)20 8361 5255
Fax: +44 (0)20 8368 3952
Web: www.luminite.co.uk
Table of contents
Popular Controllers manuals by other brands

Air Torque
Air Torque EDITION 2010 DR/SC Installation, Maintenance and Operating Instruction Manual

Motorola
Motorola MVME162LX 300 Series Installation and use

ROSSMONT
ROSSMONT Waver Master WR-2CH quick guide

Siemens
Siemens OpenAir manual

BENSHAW
BENSHAW PowerPro Series user guide

Philips
Philips Dynalite DLE1210GL installation instructions

Rohde & Schwarz
Rohde & Schwarz SpycerBox Cell Important information

J+J
J+J J3-35 quick guide

Full Gauge Controls
Full Gauge Controls ECASE EVOLUTION Assembly manual

SALUPO
SALUPO SEWAGE PLUS Instruction and installation manual

FIBARO
FIBARO RGBW CONTROLLER 2 operating manual

Mitsubishi
Mitsubishi MELSEC-F Training manual