SA122
WALL MOUNTED 500W
HALOGEN FLOODLIGHT
•Floodlight
‚Cover Screw
ƒJunction Box
„Glass Cover
…Mounting Bracket
SAFETY PRECAUTIONS
lThe device is designed for indoor/outdoor
usage.
lDonotoperatetheunitwithwethandsorwhile
standing on a wet or damp surface.
lAvoidoperating the Floodlight or leaving power
cord in standing water which may lead to a
fatal shock.
lDo not remove the wire guard or tempered
glass while the Floodlight is ON.
lKeep away from flammable objects and
handle with care.
lIf a new glass is replaced, use only tempered
glass of equal thickness.
lIf an extension cord is needed, a 3 prong
grounded plug must be featured.
lFollow strictly the regulations when
connecting the electrical system to this
Floodlight.
lMinimum safe distance to flammable areas
is 1 M.
IMPORTANT
Some local building codes may require installation of
this product by a qualified electrician.
Check your local codes as they apply to your situation.
If the house wiring is of aluminum,
consult with an electrician about proper wiring
methods.
Before proceeding with the installation, TURN
OFF THE POWER TO THE LIGHTING CIRCUIT
AT THE CIRCUIT BREAKER OR FUSE BOX TO
AVOID ELECTRICAL SHOCK.
CHOOSING A MOUNTING LOCATION &
WIRING REQUIREMENT
(1) Select a location for the unit either on a wall or
eaves at a height of 1.8~2M above the ground
to prevent tampering.
(2) Install a wall switch adjacent to power
source. (FIGURE 1)
FIGURE 1
(3) Switch off the power source.
(4) Remove the mounting bracket from the
floodlight. Drill the wall and screw the bracket
onto the wall using suitable plastic wall plugs
and screws.
Note: Do not at this stage re-attach the
floodlight to the bracket.
(5) Unscrew two screws at the rear of junction
box then remove junction’s box back plate.
(6) Loosen two screws on the pressure block.
(FIGURE 2)
1
FIGURE 2
(7) Route the power cord through the cable gland
and pressure block. (FIGURE 3)
FIGURE 3
(8) Strip approx. 6-8mm insulating part of the
wires from the power cord.
(9) Connect the BROWN wire to the terminal block
“L “mark (Live wire).
Connect the BLUE wire to the terminal
block “N “mark (Neutral wire)
Connect the YELLOW/GREEN wire to the
terminal block “ “ mark (Ground
wire).(FIGURE 4)
FIGURE 4
(10)Use the pressure block and its two screws to
fix the power cord, then cover back the back
plate.
(11)Secure the Floodlight with its mounting
bracket using the screws provided.
Note: The Floodlight can be installed only
horizontally (see the FIGURE 5a), not
Vertically (see the FIGURE 5b).
2
HORIZONTAL VERTICAL
FIGURE 5a & 5b
BULB INSTALLATION
CAUTION : Always handle quartz halogen bulbs with
a soft cloth. Do not touch the bulb with your bare hand
as it will shorten the life of the bulb.
(1) Do not touch the Floodlight while it is in use or still
hot. Allow it to cool (about 5 minutes) before
touching it.
(2) Do not use halogen bulb rated higher than 500 watts.
(3) Disconnect the power cord or wall switch and then
remove cover screw on the top of the unit to open.
(4) Remove the glass cover. The cover is mounted on
hinges and will swing open.
(5) Install bulb by inserting one end first and depressing
until enough clearance is gained to seat the other
end of the socket. Rotate halogen bulb to assure
proper seating.
(6) To change a new bulb, lift one end of the bulb to
remove. Install a new bulb with the same steps
above.
TROUBLESHOOTING
Lights do not light on at all.
lCheck power supply.
lMake sure that the bulbs have not burned out.
lCheck all wiring and connections.
Others
lThe specification of protective shield shall
consult to local service agent.
SPECIFICATIONS
Power Requirement AC 220 ~ 240V/ 50Hz
Lighting Load Max. 500W Halogen
Bulb
Waterproof IP44
Protection Class Class I
Power Cord Requirement H05RN-F, 3G, 1.0mm²
Swiveling Angle Vertical 90°
3 INS122EVSPEB

Other Lynteck Floodlight manuals

Lynteck TITAN TRS21TX User manual

Lynteck

Lynteck TITAN TRS21TX User manual

Lynteck TITAN TF20WLED User manual

Lynteck

Lynteck TITAN TF20WLED User manual

Popular Floodlight manuals by other brands

Night Watcher NW765 instruction manual

Night Watcher

Night Watcher NW765 instruction manual

REV HFGT400AST Operation and maintenance manual

REV

REV HFGT400AST Operation and maintenance manual

superbrightleds FLCKM Series user manual

superbrightleds

superbrightleds FLCKM Series user manual

Timeguard LEDX10PIRB Installation & operating instructions

Timeguard

Timeguard LEDX10PIRB Installation & operating instructions

Show Tec POWER SPOT 9 G6 TOUR V1 manual

Show Tec

Show Tec POWER SPOT 9 G6 TOUR V1 manual

CO/Tech RD224EGL instruction manual

CO/Tech

CO/Tech RD224EGL instruction manual

Claypaky ALPHA SPOT HPE 1500 instruction manual

Claypaky

Claypaky ALPHA SPOT HPE 1500 instruction manual

Show Tec Spider LED user guide

Show Tec

Show Tec Spider LED user guide

Kemot URZ3368 manual

Kemot

Kemot URZ3368 manual

Jolly LX-740 user manual

Jolly

Jolly LX-740 user manual

BREE LIGHTING BR-FL70W-02 quick start guide

BREE LIGHTING

BREE LIGHTING BR-FL70W-02 quick start guide

MAXSA 40331 Assembly & operating instructions

MAXSA

MAXSA 40331 Assembly & operating instructions

Philips MVF 406, 1800 W cat A1 Field service manual

Philips

Philips MVF 406, 1800 W cat A1 Field service manual

Red Arrow FLSMDPC10BOPI installation instructions

Red Arrow

Red Arrow FLSMDPC10BOPI installation instructions

ecolight SE1049-BP2-02LF0-E user manual

ecolight

ecolight SE1049-BP2-02LF0-E user manual

ADJ Event Bar Q4 User instructions

ADJ

ADJ Event Bar Q4 User instructions

DTS XR3000 SPOT CMY user manual

DTS

DTS XR3000 SPOT CMY user manual

ANSMANN FL800R manual

ANSMANN

ANSMANN FL800R manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.