M Climate Bobbie B-05 User manual

Installation manual

Package Included
Bobbie
Fasteners Installation
template
Temperature sensors 1m cable 3x2,5m2
2x brackets Installation
stickers

Compatibility
Bobbie connects to your home Wi-Fi network so you can communicate with it through the
internet from your smartphone. There’s a wired connection between Bobbie and your water
heater so the device works as a switch. Bobbie connects to the 100-240V ~ mains supply. This
makes it applicable to all brands and models of boilers in the market consuming up to 32A. Т
hanks to our intuitive mobile app, you can heat up the water at home, no matter where you
are. Bobbie will learn your habits and after that you will never have to think about hot water
issues. You will have hot water whenever you need it.
Technical characteristics
Power Supply: 100-240V~, 50/60Hz
IP Protection class: IP23
Self-consumption: 50mA
Switching current: 32А
Wire cross section: 1,5 – 4mm2
Recommended ircuit breaker: 50Amax, 250V~
Sensors: temperature 0-90оC, E-meter
The controller is designed to using with TN/IT distributed alternating voltage power supply
systems
Connectivity: 2.4GHz Wi-Fi b/g/n, (868MHz W-MBUS Т2)
Mounting position: according to the specified symbols
Control: Wi-Fi, multifunctional button
Indications:
- Power ON
- Wi-Fi connected
- Current consumption
Size: 100x150x34mm
Weight: 400 g
Material: PC + ABS

Environmental conditions in which the
device is intended to operate:
- Indoor using;
- for altitude up to 2000m;
- for an ambient temperature: 0°С to +50°С;
- for maximum relative humidity of 80% for temperature up to 31°С, decreasing
linearly to 25% relative humidity at temperature 50°С;
- for supply voltage deviation of up to ± 10% of the declared supply voltage range;
- for use under the overvoltage category II;
- for environment with a degree of contamination 2 (PD2).
Storage and transport conditions:
- for an ambient temperature -20°С to +60°С;
- for relative humidity 5% to 90% without condensation

Safety instructions
Please read the safety instructions before installing the device!
Failure to follow the recommended instructions in this manual may be dangerous
or be in violation of the law. The manufacturer Melissa Climate Plc., Is not respon-
sible for any loss or damage caused by failure to follow the instructions in the
operating instructions.
The installation and connection of the device to the power supply must be carried
out in accordance with the national electrical installation legislation.
Safety installation!
1. Ensure that the device is attached stable to the wall!
2. The device is designed to control active loads with a cosof more than 0.95
3. All works of installation, service and repair on the device is only performed when
it is securely disconnected from the power supply.
4. It is mandatory to disconnect the power supply via a bipolar switch / fuse!
5. Ensure that the connecting wires are securely fastened by the clamping screw
of the terminals!
6. The connection terminals are provided for wires with a cross section of 1.5mm2
to 4mm2
7. Do not use wires with different cross section!

Safety instructions
8. All connections to the controller must be carried out with cables with an insula-
tion resistance not less than those with PVC insulation T90 ° C when it is intended
to operate at ambient temperatures under 30 ° C and reaching 40 ° C, and with
cables with an insulation resistance not lower than those with PVC insulation T105
° C when the controller will operate at ambient temperatures under 40 ° C.
9. Тhe device must be installed vertically, with the power cables on the underside
of the device.
10. The controller is suitable for use in rooms, including bathrooms, in places
where it is not exposed to the direct impact of splashing water and water jets in
areas where the degree of protection IP23 is allowed.
11. The cables must be mounted with the plastic fastener bracket provided in the
kit.
12. Mount the protective plastic cover described in step 12 , indicating the
danger of dangerous voltages
13. In case of failure and burn of the built-in RF1 fuse resistor, the terminals of the
controller remain under dangerous voltage!
14. Mount Bobbie top cover and make sure it is securely attached to the base.
15. Do not install near sources of vibration.

Safety instructions
16. Please check in every six months:
- condition of the terminals
- the reliability of connecting the external cables
- the reliability of cable fixation
- the integrity of the outer envelope
- the outer shells and insulation integrity of the connecting cable
- If necessary, tighten terminal screws and cable clamps.
An external bipolar switch or an automatic two-pole circuit breaker must be
provided for the device to disconnect from the power supply network with a split
between the contacts at all poles, ensuring complete disconnection under the
overvoltage category III. The switch / circuit breaker must be built into the fixed
wiring in accordance with the electrical regulations.
The on/off button of the controller only serves to functionally shut off the device
and can not be regarded as a disconnect from mains supply, and only such an
instrument may be the external automatic circuit breaker provided during installa-
tion according to the instructions.
Cleaning the device is allowed using a dry or lightly moistened cloth, which specifi-
cally prohibits the use of aggressive or abrasive detergents.

Safety instructions
Regarding to the application and service groups for HVES / SAS, the device is used
in automation and HVAC, such as the management of accumulating water heaters
for the purpose of energy management and user comfort.
Regarding classification related to the safety of the output and all applicable
restrictions, the device falls into the following groups:
- overvoltage protection class →II;
- type of the chain → SELV;
- topology of the network →wireless communication.
Installation of the device shall be carried out in accordance with the manufactur-
er's instructions, in compliance with the requirements of DL 60364-4-41 and
national legislation.
Attention!
This product is not a toy. Beware of children and animals!

Legal Notices
All information, including but not limited to, features, functionality, and / or other
product specifications are subject to change without notice. MClimate retains all
rights to review or update its products, software or documentation without being
required to notify any natural or legal person.
The MClimate and MClimate logo are trademarks of Melissa Climate Jsc. All other
brands and product names mentioned herein are trademarks of their respective
owners.

Installation
1. Shut off power supply through the main automatic switch.
Be sure to disconnect
the boiler power, using
a mains tester.
switchboard
&
2. Remove the bottom cover of
the water heater.
Use the water heater installation manual to
safely remove the protective cover. Ensure
that this is allowed by the manufacturer
and that you do not violate the warranty of
the appliance.
bipolar switch to shut
off the water heater
power supply.

Installation
3. Disconnect the power wires.
Use the stickers provided in the kit to indicate the
purpose of each of the water heater power lines.
Labels are labeled with L, N and symbols. Stick
each tape onto the wire with the appropriate
symbol. The symbols can be found on the terminal
to which each wire is connected. Once you have
tagged the wires you can disconnect them from
the terminals.
4. Put the pattern on the wall.
Place the template on the designated
mounting location to mark the drilling
points on the wall.
LN
Use a mains tester to make sure that there is no
voltage in the supply wires.

Installation
5. Mount Bobbie on the wall.
Use the fasteners and make sure the
device is stably attached to the wall.
6. Mount the wires you have
marked in step 3.
Connect wire L to the terminal Lin,
wire N to terminal N and ware
marked with terminal G.
NLout LinG
NLout LinG

1
Installation
Connect the brown wire to the terminal
L of the water heater, the blue wire to
terminal N and the yellow-green wire to
the terminal marked as
The additional wire is provided in the
kit for connecting your boiler to Bobbie.
Mount the brown wire to the Lout
terminal, blue wire to terminal N and
yellow-green to terminal G.
8. Mount the additional
conductor to the water heater.
7. Connect the
additional wire.
LN
G
NLout LinG
Make sure that the wires are stable tight to the terminals!
Only wires with the same cross section must be using!
Check the maximum water heater current consumption:
Current consumption up to 16A - wire cross section: 1,5mm2
Current consumption up to 25A - wire cross section: 2,5 mm2
Current consumption up to 32A - wire cross section: 4mm2

Installation
9. Install the water
heater protective cover.
Use the water heater installation
manual to reattach the protective
cover.
10. Connect the Bobbie sensors.
The sensor cable ends with a
connector (type RJ). Put it in position 5.
5

Installation
11. Fix all cables
in the box.
Insert the cables into the
provided grooves in the box
and tighten them with the
bracket.
12. Place the plastic terminal
cover over the terminal block.
Mount the plastic terminal cover
with the bolts provided in the set,
with the symbol on the top.

13. Put Bobbie's
top cover.
Put Bobbie top cover to
assemble the device.
Installation
14. Attach the sensors
to the water
heater pipes.
Install the sensors to the
hot and cold water pipes.
The sensors must be
attached to a heat
conducting/metallic part.

&
15. Turn on the mains power.
Turn on the mains power from automatic switch in switchboard.
switchboard Bipolar switch to shut off the water
heater power supply.
Installation

Installation
16. Download the
Bobbie mobile App
You can download the Bobbie mobile app for
iOS and Android from:
www.mclimate.eu/bobbie/app
Questions?
For more information about the product and
questions related to it, visit:
www.mclimate.eu
Проектирано и създадено от MClimate в България.

Colors
Bobbie's button is surrounded by a lighted
ring that suggests Bobbie's condition.
After several flashes in pink, the condition
switches to constant yellow. At this point,
Bobbie expects a Wi-Fi configuration over
the mobile application. After successfully
configuring, flashes briefly in light blue and
then red.
Loading
Waiting for SmartConfig
Connecting to the router
Connecting to the server
Before making a connection

Colors
After successfully connecting to the
MClimate server, Bobbie starts to pulse,
suggesting that it is ready for use.
Pulse in red:
Water is heating
Pulse in Green:
Bobbie turns off water heater
Pulse in Yellow:
The water heater reached the maximum
temperature and the has turned off the
load.
Heating
Save energy
Maximum energy
Once established connection
Table of contents
Other M Climate Controllers manuals
Popular Controllers manuals by other brands

CYP
CYP CDPS-IRL Operation manual

PowerTech
PowerTech ZM9126 instruction manual

BEA
BEA Two MC50s Interlocking 4 Doors Wiring diagram

NXP Semiconductors
NXP Semiconductors MC13224V user guide

SIGOR
SIGOR 9057001 quick start guide

Sentera Controls
Sentera Controls EVSS1 Series Mounting and operating instructions

OPTI-UPS
OPTI-UPS SS1200 owner's manual

Canon
Canon imagePASS-B2 INSTALLATION PROCEDURE

Zenith
Zenith HydroTap G5 Quick start installation guide

Lenze
Lenze C 750 Mounting instructions

Franklin Electric
Franklin Electric SmartStart SSP1E-30S owner's manual