M8BS2-042
P. 1 / 3EM-5478-2 Rev.3
BEFORE USE ....
Thank you for choosing M-System. Before use, check the
package you received as below.
If you have any problems or questions with the product,
please contact M-System's Sales Office or representatives.
■ PACKAGE INCLUDES:
Installation base.......................................................(1)
■MODEL NO.
Confirm that the model number described on the product is
exactly what you ordered.
■INSTRUCTION MANUAL
This manual describes necessary points of caution when you
use this product, including installation, connection and basic
maintenance procedures.
POINTS OF CAUTION
■ CONFORMITY WITH EC DIRECTIVES
• This equipment is suitable for use in a Pollution Degree 
2 environment and in Installation Category II, with the
maximum operating voltage 300V.
Basic insulation is maintained between the input and output.
Prior to installation, check that the insulation class of this 
unit satisfies the system requirements.
• The equipment must be mounted inside a panel.
• The  equipment  must be installed such that  appropriate 
clearance and creepage distances are maintained to conform
to CE requirements. Failure to observe these requirements
may invalidate the CE conformity.
■ POWER INPUT RATINGS
•  Power  input  ratings  are  specied  by  the  model  number 
suffix code. Check the power input voltage for the unit on
the specification label.
AC power: 100 – 240V AC rating: 85 – 264V, 47 – 63 Hz,
130VA min.
DC power:  24 V DC rating: 24V ±10%, 2,5A min.
■ ENVIRONMENT
• Indoor use
• When  heavy  dust  or  metal  particles  are  present  in  the 
air, install the installation base inside proper housing and
ventilate it.
• Do not install the base where it is subjected to continuous 
vibration.  Do not apply physical impact to the unit.
• Environmental temperature must be within 0 to 55°C or 32 
to 131°F (0 to 50°C or 32 to 122°F for AC power) with relative 
humidity within 30 to 90% RH (30 to 85% RH for AC Power) 
in order to ensure adequate life span and operation.
•  Be  sure  that  the  ventilation  slits  are  not  covered  with 
cables, etc.
■ WIRING
• Do not install cables (power supply, input and output) close 
to noise sources (relay drive cable, high frequency line, etc.).
• Do not bind these cables together with those in which noises 
are present.  Do not install them in the same duct.
■ AND ....
• The unit is designed to function as soon as power is supplied, 
however, a warm up for 10 minutes is required for satisfying
complete performance described in the data sheet.
COMPONENT IDENTIFICATION
■ REAR VIEW
INSTALLATION BASE
(for Network interface) MODEL
M8BS2-042
INSTRUCTION MANUAL
MOUNTING REQUIREMENTS mm (inch)
230 (9.06)
4–M5 SCREW
50 (1.97)
Specifications
M8BS2-042
P. 2 / 3EM-5478-2 Rev.3
TERMINAL CONNECTIONS
Connect the unit referring the drawings below and the connection diagrams in the following page.
■EXTERNAL DIMENSIONS mm (inch)
• M8BS2-042-M2
CH1 CH4
1 2 34
+–+–+–+–
7.3(.29)
16–M3.5
OUTPUT TERMINALS
OUTPUT 2 TERM.
OUTPUT 1 TERM.
3
4
5
2
1
V.ADJ +–+–+–+–
100 (3.94)
50 (1.97)
210 (8.27)
230 (9.06)
250 (9.84)
156 (6.14)
132 (5.20) 26 (1.02) min.
AC POWER UNIT
5–M3.5 POWER
TERMINALS
6.6 (.26)
• M8BS2-042-R
CH1 CH4
1 2 34
+–+–+–+–
7.3(.29)
16–M3.5
OUTPUT TERMINALS
OUTPUT 2 TERM.
OUTPUT 1 TERM.
+–+–+–+–
100 (3.94)
50 (1.97)
210 (8.27)
230 (9.06)
250 (9.84)
132 (5.20) 26 (1.02) min.
3–M3.5 POWER
TERMINALS
123
92 (3.62)
POWER LED
8.6 (.34)
M8BS2-042
P. 3 / 3EM-5478-2 Rev.3
CHECKING
1) Terminal wiring: Check that all cables are correctly con-
nected according to the connection diagram.
2)  Power  input  voltage:    Check  voltage  across  the  power 
terminals.
3) Installation & environment
MAINTENANCE
Power units' standard life is expected for 10 years with aver-
age ambient temperature 35°C (95°F) and 1.0A load.  Contact 
M-System for use in extremely different conditions.
■
HOW TO REPLACETHE POWER UNIT (power suffix code: M2)
1)  Prepare Power Unit (switching regulator) model HDC10.
2)  Turn off the power supply connected to the Power Unit.
3)  Remove  the  wire  binding  and  wiring  connected  to  the 
terminal 1 – 2 and 4 – 5.
4) Loosen and remove the mounting screws A(4 places).
5)  Detach the Power Unit from the Installation Base.
6)  Attach the new Power Unit to the Installation Base and 
tighten the screws in reverse order as explained above.
+
–
+
–
AC
POWER
UNIT
4
5
FG
3
U
V
AC POWER
FG
3
2
1
+
–
+
–
■ DC Power Supply ■ AC Power Supply
OUTPUT 1
OUTPUT 1
Ch.1
OUTPUT
Ch.4
OUTPUT
OUTPUT 1
OUTPUT 1
+
–
+
–
OUTPUT 2 OUTPUT 2
Ch.1
OUTPUT +
–
+
–
OUTPUT 2 OUTPUT 2
Ch.4
OUTPUT
POWER
+
-
+
–
+
–
AC
POWER
UNIT
4
5
FG
3
U
V
AC POWER
FG
3
2
1
+
–
+
–
■ DC Power Supply ■ AC Power Supply
OUTPUT 1
OUTPUT 1
Ch.1
OUTPUT
Ch.4
OUTPUT
OUTPUT 1
OUTPUT 1
+
–
+
–
OUTPUT 2 OUTPUT 2
Ch.1
OUTPUT +
–
+
–
OUTPUT 2 OUTPUT 2
Ch.4
OUTPUT
POWER
+
-
■ CONNECTION DIAGRAM
M-SYSTEM WARRANTY
M-System warrants such new M-System product which it manufactures to be free from defects in materials and workmanship during the 36-month period following the date that such
product was originally purchased if such product has been used under normal operating conditions and properly maintained, M-System’s sole liability, and purchaser’s exclusive
remedies, under this warranty are, at M-System’s option, the repair, replacement or refund of the purchase price of any M-System product which is defective under the terms of this
warranty. To submit a claim under this warranty, the purchaser must return, at its expense, the defective M-System product to the below address together with a copy of its original
sales invoice.
THIS IS THE ONLY WARRANTY APPLICABLE TO M-SYSTEM PRODUCT AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY IMPLIED
WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. M-SYSTEM SHALL HAVE NO LIABILITY FOR CONSEQUENTIAL, INCIDENTAL OR
SPECIAL DAMAGES OF ANY KIND WHATSOEVER.
M-System Co., Ltd., 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN, Phone: (06) 6659-8201, Fax: (06) 6659-8510, E-mail: info@m-system.co.jp
3
4
5
2
1
V.ADJ
AA
A
A
A
1
2
3
4
5
: Mounting screws with
washer, M3 x 6 (4 pls.)
: 24V DC (+)
: 24V DC (–)
: FG
: AC power input (U)
: AC power input (V)

Other M-system I/O System manuals

M-system R7E-MS4 User manual

M-system

M-system R7E-MS4 User manual

M-system R7M-DAC16C-R User manual

M-system

M-system R7M-DAC16C-R User manual

M-system R80DAT16A2 User manual

M-system

M-system R80DAT16A2 User manual

M-system R3-DA64A User manual

M-system

M-system R3-DA64A User manual

M-system R7 Series User manual

M-system

M-system R7 Series User manual

M-system R1M-P4 User manual

M-system

M-system R1M-P4 User manual

M-system R3-US4 User manual

M-system

M-system R3-US4 User manual

M-system Devicenet R7F4HD-DC32A User manual

M-system

M-system Devicenet R7F4HD-DC32A User manual

M-system R7C-DA16 User manual

M-system

M-system R7C-DA16 User manual

M-system R3-SV8A User manual

M-system

M-system R3-SV8A User manual

M-system R7D-SV4 User manual

M-system

M-system R7D-SV4 User manual

M-system R3-SV4 User manual

M-system

M-system R3-SV4 User manual

M-system R7M-DC8C User manual

M-system

M-system R7M-DC8C User manual

M-system R7ML-DC16B-R User manual

M-system

M-system R7ML-DC16B-R User manual

M-system R6S-DA4 User manual

M-system

M-system R6S-DA4 User manual

M-system R7F4HEIP-DAC16B User manual

M-system

M-system R7F4HEIP-DAC16B User manual

M-system R7 Series User manual

M-system

M-system R7 Series User manual

M-system R10M-CT4E User manual

M-system

M-system R10M-CT4E User manual

M-system R7ML-TS4 User manual

M-system

M-system R7ML-TS4 User manual

M-system R7HL-PA4E User manual

M-system

M-system R7HL-PA4E User manual

M-system R7 Series User manual

M-system

M-system R7 Series User manual

M-system R3-SV4 User manual

M-system

M-system R3-SV4 User manual

M-system R8-PA4 User manual

M-system

M-system R8-PA4 User manual

M-system R7D-YS2/UL User manual

M-system

M-system R7D-YS2/UL User manual

Popular I/O System manuals by other brands

MG R7F4DH-1-DAC16B instruction manual

MG

MG R7F4DH-1-DAC16B instruction manual

WAGO I/O-SYSTEM 750 510 376 07 quick start

WAGO

WAGO I/O-SYSTEM 750 510 376 07 quick start

QTS AN-X2-MOD-MON user manual

QTS

QTS AN-X2-MOD-MON user manual

ICP DAS USA ET-8KP4-MTCP quick start

ICP DAS USA

ICP DAS USA ET-8KP4-MTCP quick start

ELPRO 905U-L installation manual

ELPRO

ELPRO 905U-L installation manual

Siemens 7XV5673 Device manual

Siemens

Siemens 7XV5673 Device manual

Sony LKRI-005 operating instructions

Sony

Sony LKRI-005 operating instructions

YASKAWA AI-14B user manual

YASKAWA

YASKAWA AI-14B user manual

NI 9206 Getting started guide

NI

NI 9206 Getting started guide

Allen-Bradley C Series installation instructions

Allen-Bradley

Allen-Bradley C Series installation instructions

Grundfos IO 241 Installation and operating instructions

Grundfos

Grundfos IO 241 Installation and operating instructions

Allen-Bradley 1746-INT4 quick start

Allen-Bradley

Allen-Bradley 1746-INT4 quick start

Grenton DIGITAL IN Z-Wave INP-038-Z-04 manual

Grenton

Grenton DIGITAL IN Z-Wave INP-038-Z-04 manual

CARLO GAVAZZI SH2RE1A424 instruction manual

CARLO GAVAZZI

CARLO GAVAZZI SH2RE1A424 instruction manual

WAGO WAGO-I/O-SYSTEM 750 Series manual

WAGO

WAGO WAGO-I/O-SYSTEM 750 Series manual

National Instruments 9237 CALIBRATION PROCEDURE

National Instruments

National Instruments 9237 CALIBRATION PROCEDURE

SIGMA TEK DI 080 instruction manual

SIGMA TEK

SIGMA TEK DI 080 instruction manual

Siemens SIMATIC ET 200SP manual

Siemens

Siemens SIMATIC ET 200SP manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.