EnglishDeutsch
 logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. M-system
  6. •
  7. I/O System
  8. •
  9. M-system M8BS2-042 User manual

M-system M8BS2-042 User manual

Other M-system I/O System manuals

M-system R7C-DA16 User manual

M-system

M-system R7C-DA16 User manual

M-system R3-SV4 User manual

M-system

M-system R3-SV4 User manual

M-system R7K4F Series User manual

M-system

M-system R7K4F Series User manual

M-system R30YN16A User manual

M-system

M-system R30YN16A User manual

M-system R7L-RS4-R User manual

M-system

M-system R7L-RS4-R User manual

M-system R8-DCM16ALZ User manual

M-system

M-system R8-DCM16ALZ User manual

M-system R30SVF4 User manual

M-system

M-system R30SVF4 User manual

M-system M5SN-AA User manual

M-system

M-system M5SN-AA User manual

M-system R3-DA8C User manual

M-system

M-system R3-DA8C User manual

M-system R7HL-PA4E User manual

M-system

M-system R7HL-PA4E User manual

M-system R7F4HEIP-DC16A User manual

M-system

M-system R7F4HEIP-DC16A User manual

M-system R7L-EA16 User manual

M-system

M-system R7L-EA16 User manual

M-system Devicenet R7F4HD-DC32A User manual

M-system

M-system Devicenet R7F4HD-DC32A User manual

M-system R7E-PA8 User manual

M-system

M-system R7E-PA8 User manual

M-system R7M-DAC16C-R User manual

M-system

M-system R7M-DAC16C-R User manual

M-system R7M-EA8/UL User manual

M-system

M-system R7M-EA8/UL User manual

M-system R5 Series User manual

M-system

M-system R5 Series User manual

M-system R7F4DC-DA16A-C User manual

M-system

M-system R7F4DC-DA16A-C User manual

M-system R7D-PA8 User manual

M-system

M-system R7D-PA8 User manual

M-system R7C-SV4 User manual

M-system

M-system R7C-SV4 User manual

M-system R30SVF4 User manual

M-system

M-system R30SVF4 User manual

M-system Devicenet R7F4DD-DA16A-H User manual

M-system

M-system Devicenet R7F4DD-DA16A-H User manual

M-system R7F4HC-DC32B-K User manual

M-system

M-system R7F4HC-DC32B-K User manual

M-system R3-TS4 User manual

M-system

M-system R3-TS4 User manual

Popular I/O System manuals by other brands

WAGO 750-344 manual

WAGO

WAGO 750-344 manual

Teknim TWM-1887 Installation & user manual

Teknim

Teknim TWM-1887 Installation & user manual

Intelligent Appliance IA-2662-E user manual

Intelligent Appliance

Intelligent Appliance IA-2662-E user manual

BERGHOF ECC DIO 16/16 User handbook

BERGHOF

BERGHOF ECC DIO 16/16 User handbook

Advantech PCM-27J3AU Startup manual

Advantech

Advantech PCM-27J3AU Startup manual

Festo CP-E08-M12-CL manual

Festo

Festo CP-E08-M12-CL manual

Measurement Computing PCI-DAS64/M1/16 user guide

Measurement Computing

Measurement Computing PCI-DAS64/M1/16 user guide

Hitachi HX-RIO3 Series user manual

Hitachi

Hitachi HX-RIO3 Series user manual

NUUO SCB-A08 user manual

NUUO

NUUO SCB-A08 user manual

jablotron JB-110N user manual

jablotron

jablotron JB-110N user manual

Omron SYSMAC C200H Operation guide

Omron

Omron SYSMAC C200H Operation guide

DOLD SAFEMASTER M Safety Technique

DOLD

DOLD SAFEMASTER M Safety Technique

ABB OPT-MF-001 user manual

ABB

ABB OPT-MF-001 user manual

Omron SYSMAC C2000H Operation guide

Omron

Omron SYSMAC C2000H Operation guide

Helmholz TB20 manual

Helmholz

Helmholz TB20 manual

ICP DAS USA tM-AD2 quick start

ICP DAS USA

ICP DAS USA tM-AD2 quick start

Automationdirect.com DL305 manual

Automationdirect.com

Automationdirect.com DL305 manual

WAGO I/O SYSTEM 750 750-833 manual

WAGO

WAGO I/O SYSTEM 750 750-833 manual

https://manuals.online logo
https://manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2026 Manuals.Online. All Rights Reserved.

M8BS2-042
P. 1 / 3EM-5478-2 Rev.3
BEFORE USE ....
Thank you for choosing M-System. Before use, check the
package you received as below.
If you have any problems or questions with the product,
please contact M-System's Sales Office or representatives.
■ PACKAGE INCLUDES:
Installation base.......................................................(1)
■MODEL NO.
Confirm that the model number described on the product is
exactly what you ordered.
■INSTRUCTION MANUAL
This manual describes necessary points of caution when you
use this product, including installation, connection and basic
maintenance procedures.
POINTS OF CAUTION
■ CONFORMITY WITH EC DIRECTIVES
• This equipment is suitable for use in a Pollution Degree 
2 environment and in Installation Category II, with the
maximum operating voltage 300V.
Basic insulation is maintained between the input and output.
Prior to installation, check that the insulation class of this 
unit satisfies the system requirements.
• The equipment must be mounted inside a panel.
• The  equipment  must be installed such that  appropriate 
clearance and creepage distances are maintained to conform
to CE requirements. Failure to observe these requirements
may invalidate the CE conformity.
■ POWER INPUT RATINGS
•  Power  input  ratings  are  specied  by  the  model  number 
suffix code. Check the power input voltage for the unit on
the specification label.
AC power: 100 – 240V AC rating: 85 – 264V, 47 – 63 Hz,
130VA min.
DC power:  24 V DC rating: 24V ±10%, 2,5A min.
■ ENVIRONMENT
• Indoor use
• When  heavy  dust  or  metal  particles  are  present  in  the 
air, install the installation base inside proper housing and
ventilate it.
• Do not install the base where it is subjected to continuous 
vibration.  Do not apply physical impact to the unit.
• Environmental temperature must be within 0 to 55°C or 32 
to 131°F (0 to 50°C or 32 to 122°F for AC power) with relative 
humidity within 30 to 90% RH (30 to 85% RH for AC Power) 
in order to ensure adequate life span and operation.
•  Be  sure  that  the  ventilation  slits  are  not  covered  with 
cables, etc.
■ WIRING
• Do not install cables (power supply, input and output) close 
to noise sources (relay drive cable, high frequency line, etc.).
• Do not bind these cables together with those in which noises 
are present.  Do not install them in the same duct.
■ AND ....
• The unit is designed to function as soon as power is supplied, 
however, a warm up for 10 minutes is required for satisfying
complete performance described in the data sheet.
COMPONENT IDENTIFICATION
■ REAR VIEW
INSTALLATION BASE
(for Network interface) MODEL
M8BS2-042
INSTRUCTION MANUAL
MOUNTING REQUIREMENTS mm (inch)
230 (9.06)
4–M5 SCREW
50 (1.97)
Specifications
M8BS2-042
P. 2 / 3EM-5478-2 Rev.3
TERMINAL CONNECTIONS
Connect the unit referring the drawings below and the connection diagrams in the following page.
■EXTERNAL DIMENSIONS mm (inch)
• M8BS2-042-M2
CH1 CH4
1 2 34
+–+–+–+–
7.3(.29)
16–M3.5
OUTPUT TERMINALS
OUTPUT 2 TERM.
OUTPUT 1 TERM.
3
4
5
2
1
V.ADJ +–+–+–+–
100 (3.94)
50 (1.97)
210 (8.27)
230 (9.06)
250 (9.84)
156 (6.14)
132 (5.20) 26 (1.02) min.
AC POWER UNIT
5–M3.5 POWER
TERMINALS
6.6 (.26)
• M8BS2-042-R
CH1 CH4
1 2 34
+–+–+–+–
7.3(.29)
16–M3.5
OUTPUT TERMINALS
OUTPUT 2 TERM.
OUTPUT 1 TERM.
+–+–+–+–
100 (3.94)
50 (1.97)
210 (8.27)
230 (9.06)
250 (9.84)
132 (5.20) 26 (1.02) min.
3–M3.5 POWER
TERMINALS
123
92 (3.62)
POWER LED
8.6 (.34)
M8BS2-042
P. 3 / 3EM-5478-2 Rev.3
CHECKING
1) Terminal wiring: Check that all cables are correctly con-
nected according to the connection diagram.
2)  Power  input  voltage:    Check  voltage  across  the  power 
terminals.
3) Installation & environment
MAINTENANCE
Power units' standard life is expected for 10 years with aver-
age ambient temperature 35°C (95°F) and 1.0A load.  Contact 
M-System for use in extremely different conditions.
■
HOW TO REPLACETHE POWER UNIT (power suffix code: M2)
1)  Prepare Power Unit (switching regulator) model HDC10.
2)  Turn off the power supply connected to the Power Unit.
3)  Remove  the  wire  binding  and  wiring  connected  to  the 
terminal 1 – 2 and 4 – 5.
4) Loosen and remove the mounting screws A(4 places).
5)  Detach the Power Unit from the Installation Base.
6)  Attach the new Power Unit to the Installation Base and 
tighten the screws in reverse order as explained above.
+
–
+
–
AC
POWER
UNIT
4
5
FG
3
U
V
AC POWER
FG
3
2
1
+
–
+
–
■ DC Power Supply ■ AC Power Supply
OUTPUT 1
OUTPUT 1
Ch.1
OUTPUT
Ch.4
OUTPUT
OUTPUT 1
OUTPUT 1
+
–
+
–
OUTPUT 2 OUTPUT 2
Ch.1
OUTPUT +
–
+
–
OUTPUT 2 OUTPUT 2
Ch.4
OUTPUT
POWER
+
-
+
–
+
–
AC
POWER
UNIT
4
5
FG
3
U
V
AC POWER
FG
3
2
1
+
–
+
–
■ DC Power Supply ■ AC Power Supply
OUTPUT 1
OUTPUT 1
Ch.1
OUTPUT
Ch.4
OUTPUT
OUTPUT 1
OUTPUT 1
+
–
+
–
OUTPUT 2 OUTPUT 2
Ch.1
OUTPUT +
–
+
–
OUTPUT 2 OUTPUT 2
Ch.4
OUTPUT
POWER
+
-
■ CONNECTION DIAGRAM
M-SYSTEM WARRANTY
M-System warrants such new M-System product which it manufactures to be free from defects in materials and workmanship during the 36-month period following the date that such
product was originally purchased if such product has been used under normal operating conditions and properly maintained, M-System’s sole liability, and purchaser’s exclusive
remedies, under this warranty are, at M-System’s option, the repair, replacement or refund of the purchase price of any M-System product which is defective under the terms of this
warranty. To submit a claim under this warranty, the purchaser must return, at its expense, the defective M-System product to the below address together with a copy of its original
sales invoice.
THIS IS THE ONLY WARRANTY APPLICABLE TO M-SYSTEM PRODUCT AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY IMPLIED
WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. M-SYSTEM SHALL HAVE NO LIABILITY FOR CONSEQUENTIAL, INCIDENTAL OR
SPECIAL DAMAGES OF ANY KIND WHATSOEVER.
M-System Co., Ltd., 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN, Phone: (06) 6659-8201, Fax: (06) 6659-8510, E-mail: info@m-system.co.jp
3
4
5
2
1
V.ADJ
AA
A
A
A
1
2
3
4
5
: Mounting screws with
washer, M3 x 6 (4 pls.)
: 24V DC (+)
: 24V DC (–)
: FG
: AC power input (U)
: AC power input (V)