5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-8405 Rev.5 P. 1 / 3
INSTRUCTION MANUAL
DC CURRENT INPUT MODULE
(16 points, non-isolated) MODEL R3-SS16N
BEFORE USE ....
Thank you for choosing M-System. Before use, please check
contents of the package you received as outlined below.
If you have any problems or questions with the product,
please contact M-System’s Sales Office or representatives.
■PACKAGE INCLUDES:
DC current input module....................................................(1)
■MODEL NO.
Confirm Model No. marking on the product to be exactly
what you ordered.
■INSTRUCTION MANUAL
This manual describes necessary points of caution when
you use this product, including installation, connection and
basic maintenance procedures.
POINTS OF CAUTION
■CONFORMITY WITH EU DIRECTIVES
• The equipment must be mounted inside the instrument
panel of a metal enclosure.
• The actual installation environments such as panel con-
figurations, connected devices, connected wires, may af-
fect the protection level of this unit when it is integrated
in a panel system. The user may have to review the CE
requirements in regard to the whole system and employ
additional protective measures to ensure the CE conform-
ity.
■HOT SWAPPABLE MODULES
• Replacing the module does not affect other modules on
the same base. Thus, the module can be replaced while
the power is ON. However, replacing multiple modules
at once may greatly change live voltage levels. We highly
recommend to replace them one by one.
■GENERAL PRECAUTIONS
• DO NOT set the switches on the module while the power
is supplied. The switches are used only for maintenance
without the power.
■ENVIRONMENT
• Indoor use.
• When heavy dust or metal particles are present in the
air, install the unit inside proper housing with sufficient
ventilation.
• Do not install the unit where it is subjected to continuous
vibration. Do not subject the unit to physical impact.
• Environmental temperature must be within -10 to +55°C
(14 to 131°F) with relative humidity within 30 to 90% RH
in order to ensure adequate life span and operation.
■WIRING
• Do not install cables close to noise sources (relay drive
cable, high frequency line, etc.).
• Do not bind these cables together with those in which
noises are present. Do not install them in the same duct.
■UNUSED INPUT CHANNELS
• Set the unused channels to -20 – +20mA or 0 – 20mA
range. Otherwise, set them as “Unused” with PC Con-
figurator software: R3CON. Unused channels left open
with 4 – 20mA setting are equal to the input lower than
-15%, which sets a data abnormality at the PLC or the
host device.
■AND ....
• The unit is designed to function as soon as power is sup-
plied, however, a warm up for 10 minutes is required for
satisfying complete performance described in the data
sheet.
INSTALLATION
Use the Installation Base (model: R3-BSx).
R3-SS16N
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-8405 Rev.5 P. 2 / 3
COMPONENT IDENTIFICATION
1
11
12
13
14
15
16
17
18
19
20
2
3
4
5
6
7
8
9
10
ON
8
7
6
5
4
3
2
1
SW1SW2
ON
8
7
6
5
4
3
2
1
SW3
ON
4
3
2
1
■FRONT VIEW ■SIDE VIEW
ERR LED
RUN LED
Conv.
Rate Range
Input 1-8 (SW1)
or
Input 9-16 (SW2)
■STATUS INDICATOR LED
RUN indicator: Bi-color (red/green) LED;
Red when the bus A operates normally;
Green when the bus B operates normally;
Amber when both buses operate normally.
ERR indicator: Bi-color (red/green) LED;
Red with input circuit abnormality (AD con-
verter response failure);
Green in normal operating conditions.
■SIDE DIP SW
(*) Factory setting
• Input Range: SW1, SW2 (selectable per 8 channels)
INPUT 1 through INPUT 8 (SW1)
RANGEINPUT 9 through INPUT 16 (SW2)
1234
OFF OFF OFF OFF 4 – 20mA (*)
ON OFF OFF OFF 0 – 20mA
OFF ON OFF OFF -20 – +20mA
• Conversion Rate: SW3-1, 3-2
SW CONVERSION RATE
100 ms (*)50 ms 20 ms 10 ms
SW3-1 OFF ON OFF ON
SW3-2 OFF OFF ON ON
Note: Be sure to set unused SW1-5 through 1-8, SW2-5
through 2-8, SW3-3 and 3-4 to OFF.
PC CONFIGURATOR
With configurator software, settings shown below are available.
Refer to the software manual of R3CON for detailed operation.
■CHANNEL INDIVIDUAL SETTING
PARAMETER AVAILABLE RANGE DEFAULT SETTING
Zero Scale -32000 to +32000 0
Full Scale -32000 to +32000 10000
Zero Adjust -320.00 to +320.00 0.00
Full Adjust -32000 to +32000 1.0000
Unused 0: Enable
1: Disable
0: Enable
R3-SS16N
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-8405 Rev.5 P. 3 / 3
TERMINAL CONNECTIONS
Connect the unit as in the diagram below.
■EXTERNAL DIMENSIONS unit: mm (inch)
1
11
12
13
14
15
16
17
18
19
20
2
3
4
5
6
7
8
9
10
130 (5.12)
27.5 (1.08) 109 (4.29) POSITIONING
GUIDE
TERMINAL
COVER
20–M3
SCREW
6.2
(.24)
■CONNECTION DIAGRAM
*For dual redundant communication.
BUS CONNECTOR
1
2
INPUT 1
3
4
INPUT 2
5
6
INPUT 3
7
INPUT 4
INPUT 5
INPUT 6
INPUT 7
INPUT 8
INPUT 9
INPUT 10
INPUT 11
INPUT 12
INPUT 13
INPUT 14
INPUT 15
INPUT 16
COM
COM
COM
COM
15
13
16
14
8
12
11
19
10
9
17
20
18
INTERNAL POWER
INTERNAL BUS A
INTERNAL BUS B*
WIRING INSTRUCTIONS
■SCREW TERMINAL
Torque: 0.5 N·m
■SOLDERLESS TERMINAL
Refer to the drawing below for recommended ring tongue
terminal size. Spade tongue type is also applicable. Solder-
less terminals with insulation sleeve do not fit.
Applicable wire size: 0.3 – 0.5 mm2
Recommended manufacturer: Japan Solderless Terminal
MFG. Co., Ltd., Nichifu Co., Ltd.
12max
6max
3max 4min
3.2 dia.
(mm)

Other M-system I/O System manuals

M-system R7L-DC16B User manual

M-system

M-system R7L-DC16B User manual

M-system R7C-DA16 User manual

M-system

M-system R7C-DA16 User manual

M-system R7E-MS4 User manual

M-system

M-system R7E-MS4 User manual

M-system R7M-DA16-R User manual

M-system

M-system R7M-DA16-R User manual

M-system R7E-PA8 User manual

M-system

M-system R7E-PA8 User manual

M-system R7D-YS2A User manual

M-system

M-system R7D-YS2A User manual

M-system R7E-PA8-R User manual

M-system

M-system R7E-PA8-R User manual

M-system R7L-TS4-R User manual

M-system

M-system R7L-TS4-R User manual

M-system JC-ECT User manual

M-system

M-system JC-ECT User manual

M-system R7C-YS4 User manual

M-system

M-system R7C-YS4 User manual

M-system R7D-TS4/UL User manual

M-system

M-system R7D-TS4/UL User manual

M-system R1M-D1 User manual

M-system

M-system R1M-D1 User manual

M-system R30YN16A User manual

M-system

M-system R30YN16A User manual

M-system R3-SV4A User manual

M-system

M-system R3-SV4A User manual

M-system M6 Series User manual

M-system

M-system M6 Series User manual

M-system R7K4DH-1-DAC32D User manual

M-system

M-system R7K4DH-1-DAC32D User manual

M-system R3-TS8 User manual

M-system

M-system R3-TS8 User manual

M-system R7C-YV2 User manual

M-system

M-system R7C-YV2 User manual

M-system R3-PC16A User manual

M-system

M-system R3-PC16A User manual

M-system Devicenet R7F4DD-DAC16C-C User manual

M-system

M-system Devicenet R7F4DD-DAC16C-C User manual

M-system R3Y-DC16 User manual

M-system

M-system R3Y-DC16 User manual

M-system R7ML-DC16B-R User manual

M-system

M-system R7ML-DC16B-R User manual

M-system R7F4HC-DAC32C-K User manual

M-system

M-system R7F4HC-DAC32C-K User manual

M-system Devicenet R7F4HD-DC32A User manual

M-system

M-system Devicenet R7F4HD-DC32A User manual

Popular I/O System manuals by other brands

MG R7F4DH-1-DAC16B instruction manual

MG

MG R7F4DH-1-DAC16B instruction manual

WAGO I/O-SYSTEM 750 510 376 07 quick start

WAGO

WAGO I/O-SYSTEM 750 510 376 07 quick start

QTS AN-X2-MOD-MON user manual

QTS

QTS AN-X2-MOD-MON user manual

ICP DAS USA ET-8KP4-MTCP quick start

ICP DAS USA

ICP DAS USA ET-8KP4-MTCP quick start

ELPRO 905U-L installation manual

ELPRO

ELPRO 905U-L installation manual

Siemens 7XV5673 Device manual

Siemens

Siemens 7XV5673 Device manual

Sony LKRI-005 operating instructions

Sony

Sony LKRI-005 operating instructions

YASKAWA AI-14B user manual

YASKAWA

YASKAWA AI-14B user manual

NI 9206 Getting started guide

NI

NI 9206 Getting started guide

Allen-Bradley C Series installation instructions

Allen-Bradley

Allen-Bradley C Series installation instructions

Grundfos IO 241 Installation and operating instructions

Grundfos

Grundfos IO 241 Installation and operating instructions

Allen-Bradley 1746-INT4 quick start

Allen-Bradley

Allen-Bradley 1746-INT4 quick start

Grenton DIGITAL IN Z-Wave INP-038-Z-04 manual

Grenton

Grenton DIGITAL IN Z-Wave INP-038-Z-04 manual

CARLO GAVAZZI SH2RE1A424 instruction manual

CARLO GAVAZZI

CARLO GAVAZZI SH2RE1A424 instruction manual

WAGO WAGO-I/O-SYSTEM 750 Series manual

WAGO

WAGO WAGO-I/O-SYSTEM 750 Series manual

National Instruments 9237 CALIBRATION PROCEDURE

National Instruments

National Instruments 9237 CALIBRATION PROCEDURE

SIGMA TEK DI 080 instruction manual

SIGMA TEK

SIGMA TEK DI 080 instruction manual

Siemens SIMATIC ET 200SP manual

Siemens

Siemens SIMATIC ET 200SP manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.