manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. M-system
  6. •
  7. I/O System
  8. •
  9. M-system R5T-RS User manual

M-system R5T-RS User manual

Other M-system I/O System manuals

M-system R7F4HEIP-DC16A User manual

M-system

M-system R7F4HEIP-DC16A User manual

M-system R7F4DC-DA16A-H User manual

M-system

M-system R7F4DC-DA16A-H User manual

M-system R3-SV4 User manual

M-system

M-system R3-SV4 User manual

M-system 60C User manual

M-system

M-system 60C User manual

M-system R7L-DC16A User manual

M-system

M-system R7L-DC16A User manual

M-system R7ML-DC16B-R User manual

M-system

M-system R7ML-DC16B-R User manual

M-system R6S-DA4 User manual

M-system

M-system R6S-DA4 User manual

M-system Mini-MW Series User manual

M-system

M-system Mini-MW Series User manual

M-system R30PA2 User manual

M-system

M-system R30PA2 User manual

M-system R7HL-PA4E User manual

M-system

M-system R7HL-PA4E User manual

M-system R5-SV User manual

M-system

M-system R5-SV User manual

M-system R3-SV8A User manual

M-system

M-system R3-SV8A User manual

M-system R7M-DA16F User manual

M-system

M-system R7M-DA16F User manual

M-system R7F4HEIP-DAC16C User manual

M-system

M-system R7F4HEIP-DAC16C User manual

M-system R30SVF4 User manual

M-system

M-system R30SVF4 User manual

M-system M5XPHS User manual

M-system

M-system M5XPHS User manual

M-system R7ML-LC2 User manual

M-system

M-system R7ML-LC2 User manual

M-system R7L-TS4-R User manual

M-system

M-system R7L-TS4-R User manual

M-system R7F4HC-DC32B-K User manual

M-system

M-system R7F4HC-DC32B-K User manual

M-system R8-CT4E User manual

M-system

M-system R8-CT4E User manual

M-system R3-TS8 User manual

M-system

M-system R3-TS8 User manual

M-system R7F4DC-DAC16C-H User manual

M-system

M-system R7F4DC-DAC16C-H User manual

M-system R3-SV16N User manual

M-system

M-system R3-SV16N User manual

M-system R30NE1 User manual

M-system

M-system R30NE1 User manual

Popular I/O System manuals by other brands

SMC Networks EX600-AXA Installation & maintenance manual

SMC Networks

SMC Networks EX600-AXA Installation & maintenance manual

Siemens SIMATIC ET 200SP HA Equipment manual

Siemens

Siemens SIMATIC ET 200SP HA Equipment manual

Advantech PCM-27J3AU Startup manual

Advantech

Advantech PCM-27J3AU Startup manual

Hitachi HX-RIO3 Series user manual

Hitachi

Hitachi HX-RIO3 Series user manual

ICP DAS USA tM-AD2 quick start

ICP DAS USA

ICP DAS USA tM-AD2 quick start

IFM AL1200 operating instructions

IFM

IFM AL1200 operating instructions

Allen-Bradley D Series installation instructions

Allen-Bradley

Allen-Bradley D Series installation instructions

Allen-Bradley 1794-OF8IH installation instructions

Allen-Bradley

Allen-Bradley 1794-OF8IH installation instructions

Allen-Bradley SLC 500 1746-FIO4I user manual

Allen-Bradley

Allen-Bradley SLC 500 1746-FIO4I user manual

WAGO I/O-SYSTEM 750 manual

WAGO

WAGO I/O-SYSTEM 750 manual

System Sensor M201E installation instructions

System Sensor

System Sensor M201E installation instructions

NTP Technology Penta 721 digital I/O installation guide

NTP Technology

NTP Technology Penta 721 digital I/O installation guide

Bosch B208 user manual

Bosch

Bosch B208 user manual

Acces I/O products MPCIE-ISODIO-16 Hardware manual

Acces I/O products

Acces I/O products MPCIE-ISODIO-16 Hardware manual

ExpertDAQ EX-9017F Operation manual

ExpertDAQ

ExpertDAQ EX-9017F Operation manual

SeaLevel SeaI/O-580E user manual

SeaLevel

SeaLevel SeaI/O-580E user manual

Technosoft iPOS360x MX Technical reference

Technosoft

Technosoft iPOS360x MX Technical reference

National Instruments 776570-00 user manual

National Instruments

National Instruments 776570-00 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

BEFORE USE ....
Thank you for choosing M-System. Before use, please check
contents of the package you received as outlined below.
If you have any problems or questions with the product,
please contact M-System’s Sales Office or representatives.
■PACKAGE INCLUDES:
RTD input module...............................................................(1)
■MODEL NO.
Confirm Model No. marking on the product to be exactly
what you ordered.
■INSTRUCTION MANUAL
This manual describes necessary points of caution when
you use this product, including installation, connection and
basic maintenance procedures.
POINTS OF CAUTION
■CONFORMITY WITH EU DIRECTIVES
• The equipment must be mounted inside the instrument
panel of a metal enclosure.
• The actual installation environments such as panel con-
figurations, connected devices, connected wires, may af-
fect the protection level of this unit when it is integrated
in a panel system. The user may have to review the CE
requirements in regard to the whole system and employ
additional protective measures to ensure the CE conform-
ity.
■HOT INSERTION/REMOVAL OF MODULES
• Removing or replacing modules does not affect other mod-
ules on the same backplane. It is possible to replace them
without removing the power supply. However, replacing
multiple modules at once may greatly change line voltage
levels. We recommend that you replace them one by one.
■GENERAL PRECAUTIONS
• DO NOT set the switches while the power is supplied.
The switches are used only for maintenance without the
power.
■ENVIRONMENT
• Indoor use.
• When heavy dust or metal particles are present in the
air, install the unit inside proper housing with sufficient
ventilation.
• Do not install the unit where it is subjected to continu-
ous vibration. Do not subject the unit to physical impact.
• Environmental temperature must be within -10 to +55°C
(14 to 131°F) with relative humidity within 30 to 90% RH
in order to ensure adequate life span and operation.
■WIRING
• Do not install cables close to noise sources (relay drive
cable, high frequency line, etc.).
• Do not bind these cables together with those in which
noises are present. Do not install them in the same duct.
■AND ....
• The unit is designed to function as soon as power is sup-
plied, however, a warm up for 10 minutes is required for
satisfying complete performance described in the data
sheet.
INSTALLATION
Use the Installation Base (model: R5-BS).
RTD INPUT MODULE
(screw terminal block) MODEL R5T-RS
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-6115 Rev.3 P. 1 / 3
INSTRUCTION MANUAL
COMPONENT IDENTIFICATION
RUN
4
32
1
65
RUN LED
ON
12345678
RTD Burnout
Temp. Unit
Function
■ SIDE VIEW ■FRONT VIEW
■STATUS INDICATOR LED
RUN indicator: Bi-color (red/green) LED;
Red when the bus A operates normally;
Green when the bus B operates normally;
Amber when both buses operate normally.
■SIDE DIP SW
(*) Factory setting
• RTD Type: SW1, 2, 3, 4
SW RTD
1234
ON OFF ON OFF Cu 10 @ 25°C
OFF OFF OFF OFF Cu 50
OFF OFF OFF ON JPt 100 (JIS ’89)
ON OFF OFF OFF Pt 100 (JIS ’89)
OFF ON OFF OFF Pt 100 (JIS ’97, IEC) (*)
OFF ON ON OFF Pt 1000
ON ON OFF OFF Pt 50 Ω (JIS ’81)
OFF OFF ON OFF Ni 100
ON ON ON OFF Ni 508.4 Ω
• Temperature Unit: SW5, 6
SW TEMP. UNIT
5 6
OFF OFF °C (*)
ON OFF °F
OFF ON K (Absolute Temp)
• Burnout: SW7, 8
SW
BURNOUT7 8
INPUT 1 INPUT 2
OFF OFF Downscale
ON ON Upscale (*)
PC CONFIGURATOR
With configurator software, settings shown below are available.
Refer to the software manual of R5CON for detailed operation.
■CHANNEL INDIVIDUAL SETTING
PARAMETER AVAILABLE RANGE DEFAULT SETTING
Zero Scale -32000 to +32000 0
Full Scale -32000 to +32000 10000
Bias [Zero Adj.] -320.00 to +320.00 0.00
Gain [Span Adj.] -32000 to +32000 1.0000
Zero Base Depends on sensor type 0.00
Full Base Depends on sensor type 0.00
■CHANNEL BATCH SETTING
PARAMETER AVAILABLE RANGE DEFAULT SETTING
Limit No check mark: Limits to the scaling values equivalent to -15 % to
+115 %.
Check-marked: Limits within Zero Scale to Full Scale.
No check mark
R5T-RS
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-6115 Rev.3 P. 2 / 3
TERMINAL CONNECTIONS
Connect the unit as in the diagram below.
■EXTERNAL DIMENSIONS unit: mm (inch)
4
32
1
65
38.5 (1.52) 98.5 (3.88)
TERMINAL COVER
6–M3.5
TERMINAL
SCREWS
8.2 (.32)
7.2 (.28)
LOCKING CLAMP
90 (3.54) 5.6
(.22)
18 (.71)
POSITIONING GUIDE
■CONNECTION DIAGRAM
BUS CONNECTOR
INTERNAL
POWER
INTERNAL BUS A
INTERNAL BUS B*
*For dual redundant communication.
Note: The section enclosed by broken line is with 2-ch. option.
INPUT 1
1
2
A
B
B
RTD
3
INPUT 2
4
5
A
B
B
RTD
6
WIRING INSTRUCTIONS
■SCREW TERMINAL
Torque: 0.8 N·m
R5T-RS
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-6115 Rev.3 P. 3 / 3