manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. M-system
  6. •
  7. I/O System
  8. •
  9. M-system M8BS2-041 User manual

M-system M8BS2-041 User manual

Other M-system I/O System manuals

M-system R7 Series User manual

M-system

M-system R7 Series User manual

M-system Devicenet R7F4HD-DC32A User manual

M-system

M-system Devicenet R7F4HD-DC32A User manual

M-system R7M-DA16-R User manual

M-system

M-system R7M-DA16-R User manual

M-system R7E-PA8 User manual

M-system

M-system R7E-PA8 User manual

M-system M6 Series User manual

M-system

M-system M6 Series User manual

M-system R7I4DML3-DAC32C User manual

M-system

M-system R7I4DML3-DAC32C User manual

M-system M5SN User manual

M-system

M-system M5SN User manual

M-system R7C-YV2 User manual

M-system

M-system R7C-YV2 User manual

M-system R3-SV8A User manual

M-system

M-system R3-SV8A User manual

M-system R7K4F Series User manual

M-system

M-system R7K4F Series User manual

M-system M8BS2-042 User manual

M-system

M-system M8BS2-042 User manual

M-system R7L-DC16B-R User manual

M-system

M-system R7L-DC16B-R User manual

M-system R7D-YS2/UL User manual

M-system

M-system R7D-YS2/UL User manual

M-system R80DAT16A2 User manual

M-system

M-system R80DAT16A2 User manual

M-system M5SN User manual

M-system

M-system M5SN User manual

M-system R3-SV4A User manual

M-system

M-system R3-SV4A User manual

M-system R80 Series User manual

M-system

M-system R80 Series User manual

M-system R7ML-SV4 User manual

M-system

M-system R7ML-SV4 User manual

M-system R30MS4 User manual

M-system

M-system R30MS4 User manual

M-system 6BSN User manual

M-system

M-system 6BSN User manual

M-system R3-SS8N User manual

M-system

M-system R3-SS8N User manual

M-system R7C-YS4 User manual

M-system

M-system R7C-YS4 User manual

M-system JC-ECT User manual

M-system

M-system JC-ECT User manual

M-system R7 Series User manual

M-system

M-system R7 Series User manual

Popular I/O System manuals by other brands

SMC Networks EX600-AXA Installation & maintenance manual

SMC Networks

SMC Networks EX600-AXA Installation & maintenance manual

Siemens SIMATIC ET 200SP HA Equipment manual

Siemens

Siemens SIMATIC ET 200SP HA Equipment manual

Advantech PCM-27J3AU Startup manual

Advantech

Advantech PCM-27J3AU Startup manual

Hitachi HX-RIO3 Series user manual

Hitachi

Hitachi HX-RIO3 Series user manual

ICP DAS USA tM-AD2 quick start

ICP DAS USA

ICP DAS USA tM-AD2 quick start

IFM AL1200 operating instructions

IFM

IFM AL1200 operating instructions

Allen-Bradley D Series installation instructions

Allen-Bradley

Allen-Bradley D Series installation instructions

Allen-Bradley 1794-OF8IH installation instructions

Allen-Bradley

Allen-Bradley 1794-OF8IH installation instructions

Allen-Bradley SLC 500 1746-FIO4I user manual

Allen-Bradley

Allen-Bradley SLC 500 1746-FIO4I user manual

WAGO I/O-SYSTEM 750 manual

WAGO

WAGO I/O-SYSTEM 750 manual

System Sensor M201E installation instructions

System Sensor

System Sensor M201E installation instructions

NTP Technology Penta 721 digital I/O installation guide

NTP Technology

NTP Technology Penta 721 digital I/O installation guide

Bosch B208 user manual

Bosch

Bosch B208 user manual

Acces I/O products MPCIE-ISODIO-16 Hardware manual

Acces I/O products

Acces I/O products MPCIE-ISODIO-16 Hardware manual

ExpertDAQ EX-9017F Operation manual

ExpertDAQ

ExpertDAQ EX-9017F Operation manual

SeaLevel SeaI/O-580E user manual

SeaLevel

SeaLevel SeaI/O-580E user manual

Technosoft iPOS360x MX Technical reference

Technosoft

Technosoft iPOS360x MX Technical reference

National Instruments 776570-00 user manual

National Instruments

National Instruments 776570-00 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

M8BS2-041
P. 1 / 3EM-5478-1 Rev.3
BEFORE USE ....
Thank you for choosing M-System. Before use, check the
package you received as below.
If you have any problems or questions with the product,
please contact M-System's Sales Office or representatives.
n PACKAGE INCLUDES:
Installation base.......................................................(1)
n MODEL NO.
Check that model No. described on specification label is
exactly what you ordered.
n INSTRUCTION MANUAL
This manual describes necessary points of caution when you
use this product, installation, connection and basic mainte-
nance procedures.
POINTS OF CAUTION
n CONFORMITY WITH EC DIRECTIVES
•This equipment is suitable for use in a Pollution Degree
2 environment and in Installation Category III, with the
maximum operating voltage 300V.
Basic insulation is maintained between the input and output.
Prior to installation, check that the insulation class of this
unit satisfies the system requirements.
• The equipment must be mounted inside a panel.
• The equipment must be installed such that appropriate
clearance and creepage distances are maintained to conform
to CE requirements. Failure to observe these requirements
may invalidate the CE conformity.
n POWER INPUT RATINGS
• Power input ratings are specied by the model number
suffix code. Check the power input voltage for the unit on
the specification label.
AC power: 100 – 240V AC rating: 85 – 264V, 47 – 63 Hz,
130VA min.
DC power: 24 V DC rating: 24V ±10%, 2,5A min.
n ENVIRONMENT
• Indoor use
• When heavy dust or metal particles are present in the
air, install the installation base inside proper housing and
ventilate it.
• Do not install the base where it is subjected to continuous
vibration. Do not apply physical impact to the unit.
• Environmental temperature must be within 0 to 55°C or 32
to 131°F (0 to50°C or 32 to 122°F for AC power) with relative
humidity within 30 to 90% RH(30 to 85% RH for AC Power)
in order to ensure adequate life span and operation.
• Be sure that the ventilation slits are not covered with
cables, etc.
n WIRING
• Do not install cables (power supply, input and output) close
to noise sources (relay drive cable, high frequency line, etc.).
• Do not bind these cables together with those in which noises
are present. Do not install them in the same duct.
n AND ....
• The unit is designed to function as soon as power is supplied,
however, a warm up for 10 minutes is required for satisfying
complete performance described in the data sheet.
COMPONENT IDENTIFICATION
n REAR VIEW
MOUNTING REQUIREMENTS mm (inch)
INSTALLATION BASE
(for Network interface) MODEL
M8BS2
-041
INSTRUCTION MANUAL
Specifications
230 (9.06)
4–M5 SCREW
50 (1.97)
M8BS2-041
P. 2 / 3EM-5478-1 Rev.3
TERMINAL CONNECTIONS
Connect the unit referring the drawings below and the connection diagrams in the following page.
nEXTERNAL DIMENSIONS mm (inch)
• M8BS2-041-M2
1 2 34
+–+–+–+–
3
4
5
2
1
V.ADJ
100 (3.94)
50 (1.97)
210 (8.27)
230 (9.06)
250 (9.84)
156 (6.14)
132 (5.20) 26 (1.02) min.
AC POWER UNIT
CH1 CH4
7.2(.28)
8–M3.5
OUTPUT TERMINALS
5–M3.5 POWER
TERMINALS
CDCDCDCD
CH4CH1
ABABABAB
16–M3.5 INPUT TERMINALS
17 (.67)
CT PROTECTOR (CTR)
7.3 (.29)
6.6 (.26)
• M8BS2-041-R
1 2 34
+–+–+–+–
100 (3.94)
50 (1.97)
210 (8.27)
230 (9.06)
250 (9.84)
132 (5.20) 26 (1.02) min.
CH1 CH4
7.2(.28)
8–M3.5
OUTPUT TERMINALS
3–M3.5 POWER
TERMINALS
CDCDCDCD
CH4CH1
ABABABAB
16–M3.5 INPUT TERMINALS
17 (.67)
CT PROTECTOR (CTR)
123
92 (3.62)
POWER LED
7.3 (.29)
8.6 (.34)
M8BS2-041
P. 3 / 3EM-5478-1 Rev.3
CHECKING
1) Terminal wiring: Check that all cables are correctly con-
nected according to the connection diagram.
2) Power input voltage: Check voltage across the power
terminals.
3) Installation & environment
MAINTENANCE
Power units' standard life is expected for 10 years with aver-
age ambient temperature 35°C (95°F) and 1.0A load. Contact
M-System for use in extremely different conditions.
n
HOW TO REPLACETHE POWER UNIT (power suffix code: M2)
1) Prepare Power Unit (switching regulator) model HDC10.
2) Turn off the power supply connected to the Power Unit.
3) Remove the wire binding and wiring connected to the
terminal 1 – 2 and 4 – 5.
4) Loosen and remove the mounting screws A(4 places).
5) Detach the Power Unit from the Installation Base.
6) Attach the new Power Unit to the Installation Base and
tighten the screws in reverse order as explained above.
A
B
C
D
Ch.1
INPUT
A
B
C
D
Ch.4
INPUT
+
–
+
–
AC
POWER
UNIT
4
5
FG
3
U
V
AC POWER
FG
3
2
1
A
B
C
D
Ch.1
INPUT
A
B
C
D
Ch.4
INPUT
+
–
+
–
■ DC Power Supply ■ AC Power Supply
OUTPUT 2
OUTPUT 2
Ch.1
OUTPUT
Ch.4
OUTPUT
OUTPUT 2
OUTPUT 2
Ch.1
OUTPUT
Ch.4
OUTPUT
POWER
+
-
A
B
C
D
Ch.1
INPUT
A
B
C
D
Ch.4
INPUT
+
–
+
–
AC
POWER
UNIT
4
5
FG
3
U
V
AC POWER
FG
3
2
1
A
B
C
D
Ch.1
INPUT
A
B
C
D
Ch.4
INPUT
+
–
+
–
■ DC Power Supply ■ AC Power Supply
OUTPUT 2
OUTPUT 2
Ch.1
OUTPUT
Ch.4
OUTPUT
OUTPUT 2
OUTPUT 2
Ch.1
OUTPUT
Ch.4
OUTPUT
POWER
+
-
n CONNECTION DIAGRAM
M-SYSTEM WARRANTY
M-System warrants such new M-System product which it manufactures to be free from defects in materials and workmanship during the 36-month period following the date that such
product was originally purchased if such product has been used under normal operating conditions and properly maintained, M-System’s sole liability, and purchaser’s exclusive
remedies, under this warranty are, at M-System’s option, the repair, replacement or refund of the purchase price of any M-System product which is defective under the terms of this
warranty. To submit a claim under this warranty, the purchaser must return, at its expense, the defective M-System product to the below address together with a copy of its original
sales invoice.
THIS IS THE ONLY WARRANTY APPLICABLE TO M-SYSTEM PRODUCT AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY IMPLIED
WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. M-SYSTEM SHALL HAVE NO LIABILITY FOR CONSEQUENTIAL, INCIDENTAL OR
SPECIAL DAMAGES OF ANY KIND WHATSOEVER.
M-System Co., Ltd., 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN, Phone: (06) 6659-8201, Fax: (06) 6659-8510, E-mail: info@m-system.co.jp
3
4
5
2
1
V.ADJ
AA
A
A
A
1
2
3
4
5
: Mounting screws with
washer, M3 x 6 (4 pls.)
: 24V DC (+)
: 24V DC (–)
: FG
: AC power input (U)
: AC power input (V)