manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. M-system
  6. •
  7. I/O System
  8. •
  9. M-system R7E-EC16B User manual

M-system R7E-EC16B User manual

Other M-system I/O System manuals

M-system 15BX-4 User manual

M-system

M-system 15BX-4 User manual

M-system R7F4DD-DC16B-C User manual

M-system

M-system R7F4DD-DC16B-C User manual

M-system R3-SS16N User manual

M-system

M-system R3-SS16N User manual

M-system R7M-CT4E-R User manual

M-system

M-system R7M-CT4E-R User manual

M-system R3-DA64A User manual

M-system

M-system R3-DA64A User manual

M-system Devicenet R7F4DD-DC16B-H User manual

M-system

M-system Devicenet R7F4DD-DC16B-H User manual

M-system R7F4DC-DA16A-C User manual

M-system

M-system R7F4DC-DA16A-C User manual

M-system R7L-DC16A User manual

M-system

M-system R7L-DC16A User manual

M-system R7M-DA16-R User manual

M-system

M-system R7M-DA16-R User manual

M-system R8-SS4N User manual

M-system

M-system R8-SS4N User manual

M-system R7ML-TS4 User manual

M-system

M-system R7ML-TS4 User manual

M-system R80 Series User manual

M-system

M-system R80 Series User manual

M-system R8-YS2 User manual

M-system

M-system R8-YS2 User manual

M-system R5-SV User manual

M-system

M-system R5-SV User manual

M-system R7D-DC16B User manual

M-system

M-system R7D-DC16B User manual

M-system R10M-CT4E User manual

M-system

M-system R10M-CT4E User manual

M-system R7L-EA16 User manual

M-system

M-system R7L-EA16 User manual

M-system Devicenet R7F4DD-DAC16C-H User manual

M-system

M-system Devicenet R7F4DD-DAC16C-H User manual

M-system R7C-YV4 User manual

M-system

M-system R7C-YV4 User manual

M-system R30US4 User manual

M-system

M-system R30US4 User manual

M-system R7L-RS4-R User manual

M-system

M-system R7L-RS4-R User manual

M-system R7 Series User manual

M-system

M-system R7 Series User manual

M-system R3Y-SV8N User manual

M-system

M-system R3Y-SV8N User manual

M-system R7ML-DA16 User manual

M-system

M-system R7ML-DA16 User manual

Popular I/O System manuals by other brands

SMC Networks EX600-AXA Installation & maintenance manual

SMC Networks

SMC Networks EX600-AXA Installation & maintenance manual

Siemens SIMATIC ET 200SP HA Equipment manual

Siemens

Siemens SIMATIC ET 200SP HA Equipment manual

Advantech PCM-27J3AU Startup manual

Advantech

Advantech PCM-27J3AU Startup manual

Hitachi HX-RIO3 Series user manual

Hitachi

Hitachi HX-RIO3 Series user manual

ICP DAS USA tM-AD2 quick start

ICP DAS USA

ICP DAS USA tM-AD2 quick start

IFM AL1200 operating instructions

IFM

IFM AL1200 operating instructions

Allen-Bradley D Series installation instructions

Allen-Bradley

Allen-Bradley D Series installation instructions

Allen-Bradley 1794-OF8IH installation instructions

Allen-Bradley

Allen-Bradley 1794-OF8IH installation instructions

Allen-Bradley SLC 500 1746-FIO4I user manual

Allen-Bradley

Allen-Bradley SLC 500 1746-FIO4I user manual

WAGO I/O-SYSTEM 750 manual

WAGO

WAGO I/O-SYSTEM 750 manual

System Sensor M201E installation instructions

System Sensor

System Sensor M201E installation instructions

NTP Technology Penta 721 digital I/O installation guide

NTP Technology

NTP Technology Penta 721 digital I/O installation guide

Bosch B208 user manual

Bosch

Bosch B208 user manual

Acces I/O products MPCIE-ISODIO-16 Hardware manual

Acces I/O products

Acces I/O products MPCIE-ISODIO-16 Hardware manual

ExpertDAQ EX-9017F Operation manual

ExpertDAQ

ExpertDAQ EX-9017F Operation manual

SeaLevel SeaI/O-580E user manual

SeaLevel

SeaLevel SeaI/O-580E user manual

Technosoft iPOS360x MX Technical reference

Technosoft

Technosoft iPOS360x MX Technical reference

National Instruments 776570-00 user manual

National Instruments

National Instruments 776570-00 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

R7E-EC16B
P. 1 / 3EM-7807-K Rev.2
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: inf[email protected].jp
PNP TRANSISTOR OUTPUT EXTENSION MODULE, 16 points
(Ethernet Modbus/TCP) MODEL
R7E-EC16B
INSTRUCTION MANUAL
BEFORE USE ....
Thank you for choosing M-System. Before use, please check
contents of the package you received as outlined below.
If you have any problems or questions with the product,
please contact M-System’s Sales Office or representatives.
■PACKAGE INCLUDES:
Discrete output extension module................................... (1)
■MODEL NO.
Confirm that the model number described on the product is
exactly what you ordered.
■INSTRUCTION MANUAL
This manual describes necessary points of caution when
you use this product, including installation, connection and
basic maintenance procedures.
POINTS OF CAUTION
■CONFORMITY WITH EU DIRECTIVES
•The actual installation environments such as panel con-
figurations, connected devices and connected wires may
affect the protection level of this unit when it is integrat-
ed in a panel system. The user may have to review the CE
requirements in regard to the whole system and employ
additional protective measures to ensure CE conformity.
■POWER INPUT RATING & OPERATIONAL RANGE
•Locate the power input rating marked on the product and
confirm its operational range as indicated below:
24V DC rating: 24V ±10%, approx. 20mA
■GENERAL PRECAUTIONS
•Before you remove the unit or mount it, turn off the power
supply and output signal for safety.
■ENVIRONMENT
•Indoor use.
•When heavy dust or metal particles are present in the
air, install the unit inside proper housing with sufficient
ventilation.
•Do not install the unit where it is subjected to continuous
vibration. Do not subject the unit to physical impact.
•Environmental temperature must be within -10 to +55°C
(14 to 131°F) with relative humidity within 30 to 90% RH
in order to ensure adequate life span and operation.
■WIRING
•Do not install cables close to noise sources (relay drive
cable, high frequency line, etc.).
•Do not bind these cables together with those in which
noises are present. Do not install them in the same duct.
■AND ....
•The unit is designed to function as soon as power is sup-
plied, however, a warm up for 10 minutes is required for
satisfying complete performance described in the data
sheet.
COMPONENT IDENTIFICATION
0123456789ABCDEF
10 11 12 13
2341
15 16 17 18
7896
14
5
Discrete Output Status Indicator LED
Output Terminals
■DISCRETE OUTPUT STATUS INDICATOR LED
Discrete output extension modules have LED indicators
showing output signal status.
Contact ON: LED ON
Contact OFF: LED OFF
■OUTPUT TERMINAL ASSIGNMENT
10
+24V
11
Y1
12
Y3
1
0V
2
Y0
3
Y2
13
Y5
4
Y4
14
Y7
5
Y6
15
Y9
6
Y8
16
YB
7
YA
17
YD
8
YC
9
YE
18
YF
NO. ID FUNCTION NO. ID FUNCTION
1 0V 0V 10 +24V 24V DC (common)
2 Y0 Output 0 11 Y1 Output 1
3 Y2 Output 2 12 Y3 Output 3
4 Y4 Output 4 13 Y5 Output 5
5 Y6 Output 6 14 Y7 Output 7
6 Y8 Output 8 15 Y9 Output 9
7YA Output 10 16 YB Output 11
8 YC Output 12 17 YD Output 13
9 YE Output 14 18 YF Output 15
R7E-EC16B
P. 2 / 3EM-7807-K Rev.2
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: inf[email protected].jp
CONNECTING THE EXTENSION MODULE
1) Remove the extension connector cover located at the side
of the basic module.
2) Connect the extension module.
3) Mount the combined module on a DIN rail.
EXTERNAL DIMENSIONS unit: mm (inch)
4567
123
10 11 12 13
2341
15 16 17 18
789
6
14
5
30 (1.18) [5 (.20)]
3 (.12)5.5 (.22)
DIN RAIL
35mm wide
54 (2.13)
17 (.66)
50 (1.97) 18.5 (.73)
115 (4.53)
7–M3 SCREW
TERMINALS
for CC-Link, POWER
18–M3 SCREW
TERMINALS
for OUTPUT
6 (.24) 6 (.24)
R7E-EC16B
P. 3 / 3EM-7807-K Rev.2
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: inf[email protected].jp
CONNECTION DIAGRAM
Connect the unit as in the diagram below.
EXTENSION CONNECTOR
10
17
18
1
YD
16
YB
0V
YF
15
Y9
14
Y7
13
Y5
12
Y3
11
Y1
9YE
8YC
7YA
6Y8
5Y6
4Y4
3Y2
+24V
Y0
2
■ Output Connection Example
10
1
2
Y0
0V
+24V –
+
18
YF
WIRING INSTRUCTIONS
■SCREW TERMINAL
Torque: 0.5 N·m
■SOLDERLESS TERMINAL mm (inch)
Refer to the drawing below for recommended ring tongue
terminal size. Spade tongue type is also applicable. Solder-
less terminals with insulation sleeve do not fit.
Applicable wire size:
0.25 to 1.65 mm
2
(AWG 22 to 16)
Recommended manufacturer: Japan Solderless Terminal
MFG.Co.Ltd, Nichifu Co.,ltd
6 (.24) max
3.3 (.13) max
mm (inch)