manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. M-system
  6. •
  7. I/O System
  8. •
  9. M-system R3-SS8N User manual

M-system R3-SS8N User manual

5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-8406 Rev.4 P. 1 / 3
INSTRUCTION MANUAL
DC CURRENT INPUT MODULE
(8 points, non-isolated) MODEL R3-SS8N
BEFORE USE ....
Thank you for choosing M-System. Before use, please check
contents of the package you received as outlined below.
If you have any problems or questions with the product,
please contact M-System’s Sales Office or representatives.
■PACKAGE INCLUDES:
DC current input module....................................................(1)
■MODEL NO.
Confirm Model No. marking on the product to be exactly
what you ordered.
■INSTRUCTION MANUAL
This manual describes necessary points of caution when
you use this product, including installation, connection and
basic maintenance procedures.
POINTS OF CAUTION
■CONFORMITY WITH EU DIRECTIVES
• The equipment must be mounted inside the instrument
panel of a metal enclosure.
• The actual installation environments such as panel con-
figurations, connected devices, connected wires, may af-
fect the protection level of this unit when it is integrated
in a panel system. The user may have to review the CE
requirements in regard to the whole system and employ
additional protective measures to ensure the CE conform-
ity.
■HOT SWAPPABLE MODULES
• Replacing the module does not affect other modules on
the same base. Thus, the module can be replaced while
the power is ON. However, replacing multiple modules
at once may greatly change live voltage levels. We highly
recommend to replace them one by one.
■GENERAL PRECAUTIONS
• DO NOT set the switches on the module while the power
is supplied. The switches are used only for maintenance
without the power.
■ENVIRONMENT
• Indoor use.
• When heavy dust or metal particles are present in the
air, install the unit inside proper housing with sufficient
ventilation.
• Do not install the unit where it is subjected to continuous
vibration. Do not subject the unit to physical impact.
• Environmental temperature must be within -10 to +55°C
(14 to 131°F) with relative humidity within 30 to 90% RH
in order to ensure adequate life span and operation.
■WIRING
• Do not install cables close to noise sources (relay drive
cable, high frequency line, etc.).
• Do not bind these cables together with those in which
noises are present. Do not install them in the same duct.
■UNUSED INPUT CHANNELS
• Set the unused channels to “Unused” with PC Configu-
rator software: R3CON. Unused channels left open may
be equal to the input lower than -15%, which sets a data
abnormality at the PLC or the host device.
■AND ....
• The unit is designed to function as soon as power is sup-
plied, however, a warm up for 10 minutes is required for
satisfying complete performance described in the data
sheet.
INSTALLATION
Use the Installation Base (model: R3-BSx).
R3-SS8N
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-8406 Rev.4 P. 2 / 3
COMPONENT IDENTIFICATION
■ FRONT VIEW ■ SIDE VIEW
RUN LED
1
11
12
13
14
15
16
17
18
19
20
2
3
4
5
6
7
8
9
10
ERR LED
RUN LED
SW3
ON
4
3
2
1
Conv.
Rate
■STATUS INDICATOR LED
RUN indicator: Bi-color (red/green) LED;
Red when the bus A operates normally;
Green when the bus B operates normally;
Amber when both buses operate normally.
ERR indicator: Bi-color (red/green) LED;
Red with input circuit abnormality (AD con-
verter response failure);
Green in normal operating conditions.
■SIDE DIP SW
• Conversion Rate: SW3-1, 3-2
SW CONVERSION RATE
160 ms (*)80 ms 40 ms 20 ms
SW3-1 OFF ON OFF ON
SW3-2 OFF OFF ON ON
(*) Factory setting
Note: Be sure to set unused SW3-3 and 3-4 to OFF.
PC CONFIGURATOR
With configurator software, settings shown below are available.
Refer to the software manual of R3CON for detailed operation.
■CHANNEL INDIVIDUAL SETTING
PARAMETER AVAILABLE RANGE DEFAULT SETTING
Zero Scale -32000 to +32000 0
Full Scale -32000 to +32000 10000
Zero Adjust -320.00 to +320.00 0.00
Full Adjust -32000 to +32000 1.0000
Unused 0: Enable
1: Disable
0: Enable
R3-SS8N
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-8406 Rev.4 P. 3 / 3
TERMINAL CONNECTIONS
Connect the unit as in the diagram below.
■EXTERNAL DIMENSIONS unit: mm (inch)
1
11
12
13
14
15
16
17
18
19
20
2
3
4
5
6
7
8
9
10
130 (5.12)
27.5 (1.08) 109 (4.29)
POSITIONING
GUIDE
TERMINAL
COVER
20–M3
SCREW
6.2
(.24)
■CONNECTION DIAGRAM
1
*For dual redundant communication.
BUS CONNECTOR
6
2
4
5
7
11
8
13
12
14
15
17
18
16
–
INPUT 1
+
–
INPUT 2
+
–
INPUT 3
+
–
INPUT 4
+
–
INPUT 5
+
–
INPUT 6
+
–
INPUT 7
+
–
INPUT 8
+
3
INTERNAL POWER
INTERNAL BUS A
INTERNAL BUS B*
WIRING INSTRUCTIONS
■SCREW TERMINAL
Torque: 0.5 N·m
■SOLDERLESS TERMINAL
Refer to the drawing below for recommended ring tongue
terminal size. Spade tongue type is also applicable. Solder-
less terminals with insulation sleeve do not fit.
Applicable wire size: 0.3 – 0.5 mm2
Recommended manufacturer: Japan Solderless Terminal
MFG. Co., Ltd., Nichifu Co., Ltd.
12max
6max
3max 4min
3.2 dia.
(mm)

Other M-system I/O System manuals

M-system R7 Series User manual

M-system

M-system R7 Series User manual

M-system R80DCT16A2 User manual

M-system

M-system R80DCT16A2 User manual

M-system Remote I/O R8 Series User manual

M-system

M-system Remote I/O R8 Series User manual

M-system R3-CZ4 User manual

M-system

M-system R3-CZ4 User manual

M-system R7C-DA16 User manual

M-system

M-system R7C-DA16 User manual

M-system R7M-MS4-R User manual

M-system

M-system R7M-MS4-R User manual

M-system R3-BSW User manual

M-system

M-system R3-BSW User manual

M-system R7ML-DC16A-R User manual

M-system

M-system R7ML-DC16A-R User manual

M-system R1M-P4 User manual

M-system

M-system R1M-P4 User manual

M-system R5-SS User manual

M-system

M-system R5-SS User manual

M-system R80DAT16A2 User manual

M-system

M-system R80DAT16A2 User manual

M-system R7HL-YV2 User manual

M-system

M-system R7HL-YV2 User manual

M-system R7ML-RS4 User manual

M-system

M-system R7ML-RS4 User manual

M-system R7K4DH-1-DAC32D User manual

M-system

M-system R7K4DH-1-DAC32D User manual

M-system R3-DA64A User manual

M-system

M-system R3-DA64A User manual

M-system JC-IO User manual

M-system

M-system JC-IO User manual

M-system R7F4DC-DA16A-J User manual

M-system

M-system R7F4DC-DA16A-J User manual

M-system R30XN16A User manual

M-system

M-system R30XN16A User manual

M-system R7I4DML3-DA32A User manual

M-system

M-system R7I4DML3-DA32A User manual

M-system R7C-EA16 User manual

M-system

M-system R7C-EA16 User manual

M-system M5XPHS User manual

M-system

M-system M5XPHS User manual

M-system R3Y-DA16B User manual

M-system

M-system R3Y-DA16B User manual

M-system R7E-YV2 User manual

M-system

M-system R7E-YV2 User manual

M-system R3-RS4 User manual

M-system

M-system R3-RS4 User manual

Popular I/O System manuals by other brands

TAC Xenta 411 Handbook

TAC

TAC Xenta 411 Handbook

Siemens 6DL2804 Series Hardware installation manual

Siemens

Siemens 6DL2804 Series Hardware installation manual

Pilz PSS u2 ES 4AI I operating manual

Pilz

Pilz PSS u2 ES 4AI I operating manual

Measurement Computing miniLAB 1008 user guide

Measurement Computing

Measurement Computing miniLAB 1008 user guide

National Instruments 9225 Operating instructions and specifications

National Instruments

National Instruments 9225 Operating instructions and specifications

Puls DIMENSION CT-Series manual

Puls

Puls DIMENSION CT-Series manual

Mitsubishi GT15V-75ROUT user manual

Mitsubishi

Mitsubishi GT15V-75ROUT user manual

Automationdirect.com Productivity 2000 P2-16NA manual

Automationdirect.com

Automationdirect.com Productivity 2000 P2-16NA manual

NK TECHNOLOGIES AGT Series instructions

NK TECHNOLOGIES

NK TECHNOLOGIES AGT Series instructions

Addi-Data APCI-3000 Technical description

Addi-Data

Addi-Data APCI-3000 Technical description

ICP DAS USA tET Series quick start guide

ICP DAS USA

ICP DAS USA tET Series quick start guide

ALLEN & HEATH DX88-P Getting started guide

ALLEN & HEATH

ALLEN & HEATH DX88-P Getting started guide

Sun Microsystems Fire 6800 Assembly Installation Guide

Sun Microsystems

Sun Microsystems Fire 6800 Assembly Installation Guide

Meilhaus Electronic ME-5001 manual

Meilhaus Electronic

Meilhaus Electronic ME-5001 manual

Valcom VE8048 quick start guide

Valcom

Valcom VE8048 quick start guide

Datexel DAT8016 Setup manual

Datexel

Datexel DAT8016 Setup manual

National Instruments PXI-7830R Getting started

National Instruments

National Instruments PXI-7830R Getting started

INVT EC-IO801 user manual

INVT

INVT EC-IO801 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.