manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. M-system
  6. •
  7. Industrial Equipment
  8. •
  9. M-system M5XADS User manual

M-system M5XADS User manual

5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-2777 P. 1 / 4
INSTRUCTION MANUAL
ADDER
(PC programmable) MODEL M5XADS
BEFORE USE ....
Thank you for choosing M-System. Before use, please check
contents of the package you received as outlined below.
If you have any problems or questions with the product,
please contact M-System’s Sales Office or representatives.
■PACKAGE INCLUDES:
Signal conditioner ...............................................................(1)
■MODEL NO.
Confirm Model No. marking on the product to be exactly
what you ordered.
■INSTRUCTION MANUAL
This manual describes necessary points of caution when
you use this product, including installation, connection and
basic maintenance procedures.
The M5XADS is programmable using the PC Configurator
Software. For detailed information on the PC configuration,
refer to the M5CFG users manual. The M5CFG PC Con-
figurator Software is downloadable at M-System’s web site:
https://www.m-system.co.jp
POINTS OF CAUTION
■CONFORMITY WITH EU DIRECTIVES
• The equipment must be mounted inside a panel.
• The actual installation environments such as panel con-
figurations, connected devices, connected wires, may af-
fect the protection level of this unit when it is integrated
in a panel system. The user may have to review the CE
requirements in regard to the whole system and employ
additional protective measures to ensure the CE conform-
ity.
■POWER INPUT RATING & OPERATIONAL RANGE
• Locate the power input rating marked on the product and
confirm its operational range as indicated below:
24V DC rating: 24V ±10%, ≤ 1W
■GENERAL PRECAUTIONS
• Before you remove the unit or mount it, turn off the power
supply and input signal for safety.
■ENVIRONMENT
• Indoor use.
• When heavy dust or metal particles are present in the
air, install the unit inside proper housing with sufficient
ventilation.
• Do not install the unit where it is subjected to continuous
vibration. Do not subject the unit to physical impact.
• Environmental temperature must be within -20 to +65°C
(-4 to +149°F) with relative humidity within 30 to 90%
RH in order to ensure adequate life span and operation.
■WIRING
• Do not install cables close to noise sources (relay drive
cable, high frequency line, etc.).
• Do not bind these cables together with those in which
noises are present. Do not install them in the same duct.
• Install lightning surge protectors for those wires connect-
ed to remote locations.
■AND ....
• The unit is designed to function as soon as power is sup-
plied, however, a warm up for 10 minutes is required for
satisfying complete performance described in the data
sheet.
COMPONENT IDENTIFICATION
TerminalCover
PowerIndicatorLED
ConfiguratorJack
Body
Specification
OutputSettingDIPSW
InputSettingDIPSW
(side)
M5XADS
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-2777 P. 2 / 4
INSTALLATION
Set the unit so that its DIN rail adapter is at the bottom.
■MOUNTING THE UNIT ON A DIN RAIL
A)Hang the upper hook at the rear side of unit on the DIN
rail.
B)Push in the lower in keeping pressing the unit to the DIN
rail.
A
B
DIN rail
■REMOVING THE UNIT
A)Pull down the DIN rail adaptor using a minus screwdriv-
er.
B)Pull out the lower part of the unit.
C)Remove the upper part from the DIN rail.
A
Slider
C
B
TERMINAL CONNECTIONS
Connect the unit as in the diagram below or refer to the connection diagram on the side of the unit.
■EXTERNAL DIMENSIONS unit: mm [inch]
94 [3.70]3 [.12]
25 [.98] 41 [1.61] (3.3 [.13])
• When mounting, no extra space is needed between units.
DIN RAIL
35mm wide
8–M3.5 SCREW
7.3 [.29]
12
34
56
78
■CONNECTION DIAGRAM
4
3
1
2
JACK
Configurator Jack
+
–
OUTPUT
7
8
5
6
+
–
POWER
+
-
INPUT 1
+
-
INPUT 2
WIRING INSTRUCTIONS
■SCREW TERMINAL
Torque: 0.8 N·m
M5XADS
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-2777 P. 3 / 4
EXTERNAL VIEWS
■LEFT VIEW ■FRONT VIEW
Output Setting
DIP SW Input Setting
DIP SW
1
2
3
4
5
6
SW1
On
Power Indicator LED
Configurator Jack
1
2
3
4SW2
On
■RIGHT VIEW
OUTPUT RANGING
The internal DIP switch setting is required to select output types before setting a precise output range using PC Configurator
Software (model: M5CFG).
For detailed information on the PC configuration, refer to the M5CFG users manual.
Table 1. Input range
Input range Input 1 Input 2
SW2-1 SW2-2 SW2-3 SW2-4
0 - 50 mA DC ON OFFF ON OFF
-1000 - +1000 mV DC OFF ON OFF ON
-10 - +10 V DC OFF OFF OFF OFF
Table 2. Output type
Output Type SW1
123456
0 – 20 mA ON OFF OFF OFF ON OFF
-5 – +5 V OFF ON ON OFF OFF ON
-10 – +10 V OFF ON OFF ON OFF ON
M5XADS
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-2777 P. 4 / 4
CHECKING
1) Terminal wiring: Check that all cables are correctly con-
nected according to the connection diagram.
2) Check DIP switch setting.
3) Power input voltage: Check voltage across the terminal
7 – 8 with a multimeter.
4) Input: Check that the input signal is within 0 – 100% of
the full-scale.
5) Output: Check that the load resistance meets the de-
scribed specifications.
POWER INDICATOR LED
The transmitter is provided with a power indicator LED
which blinks in different patterns indicating various oper-
ating status.
The following figure indicates typical patterns.
LEDONOFFPATTERNSTRANSMITTERSTATUS
Downloadingthesetting
Rangesetting
Fineadjusting
Supplyingafixedoutput
Normal
AbnormalOperation
(corruptionofconfigurationdata)
80ms
EQUATION
X0= K0{K1(X1+ A1) + K2(X2+ A2)} + A0
X1- X2: input signal (%) -2 - +102 %
K0- K2: gain (no units) ±29.999
A0- A2: bias (%) ±299.99 %
Factory default setting
K0= 1, K1= 1, K2= 1, A0= 0%, A1= 0%, A2= 0%
MAINTENANCE
Regular calibration procedure is explained below:
■CALIBRATION
Warm up the unit for at least 10 minutes. Apply the input
signals which should lead the calculated results as 0%, 25%,
50%, 75% and 100%. Check that the output signal for the
respective input signal remains within accuracy described
in the data sheet.
When the output is out of tolerance, recalibrate the unit us-
ing the PC Configurator Software (model: M5CFG).
LIGHTNING SURGE PROTECTION
M-System offers a series of lightning surge protector for
protection against induced lightning surges. Please contact
M-System to choose appropriate models.

Other M-system Industrial Equipment manuals

M-system R7D-EC16A User manual

M-system

M-system R7D-EC16A User manual

M-system 10JFX User manual

M-system

M-system 10JFX User manual

M-system M8BS-16K2 User manual

M-system

M-system M8BS-16K2 User manual

M-system M8DYH User manual

M-system

M-system M8DYH User manual

M-system JFX1 User manual

M-system

M-system JFX1 User manual

M-system M5VV User manual

M-system

M-system M5VV User manual

M-system M8BS2-082 User manual

M-system

M-system M8BS2-082 User manual

M-system M8BS-16Y1 User manual

M-system

M-system M8BS-16Y1 User manual

M-system M8BS-16K1 User manual

M-system

M-system M8BS-16K1 User manual

M-system M8BSC-8 User manual

M-system

M-system M8BSC-8 User manual

M-system M8BS-16U1 User manual

M-system

M-system M8BS-16U1 User manual

M-system M8DY1 User manual

M-system

M-system M8DY1 User manual

M-system BX-16G-B User manual

M-system

M-system BX-16G-B User manual

M-system M5PP User manual

M-system

M-system M5PP User manual

M-system M8BS-16U5 User manual

M-system

M-system M8BS-16U5 User manual

M-system R3-NL1 User manual

M-system

M-system R3-NL1 User manual

Popular Industrial Equipment manuals by other brands

Climax SHARK FIN DEFENDER operating manual

Climax

Climax SHARK FIN DEFENDER operating manual

Pepperl+Fuchs ECHO-D Brief instructions

Pepperl+Fuchs

Pepperl+Fuchs ECHO-D Brief instructions

TREND CRT/MK3 Original instructions

TREND

TREND CRT/MK3 Original instructions

Aerovent AEHP Installation, operation & maintenance manual

Aerovent

Aerovent AEHP Installation, operation & maintenance manual

ABB XAC24807 Operation manual

ABB

ABB XAC24807 Operation manual

Siemens 3VL9400-3HF0 Series operating instructions

Siemens

Siemens 3VL9400-3HF0 Series operating instructions

Quick XR8 Installation and use manual

Quick

Quick XR8 Installation and use manual

Ultra Optics Mini2 Operation and maintenance manual

Ultra Optics

Ultra Optics Mini2 Operation and maintenance manual

AIE G Series INSTALL & MAINTENANCE MANUAL

AIE

AIE G Series INSTALL & MAINTENANCE MANUAL

Matsing MS-MBA-3.3.2-C2-H2-L2-I instruction manual

Matsing

Matsing MS-MBA-3.3.2-C2-H2-L2-I instruction manual

Transforming Technologies IN1202-22 Operation manual

Transforming Technologies

Transforming Technologies IN1202-22 Operation manual

YoraHome 6550 user manual

YoraHome

YoraHome 6550 user manual

Gabocom KKHR Installation instruction

Gabocom

Gabocom KKHR Installation instruction

Danfoss VLT 3006 product manual

Danfoss

Danfoss VLT 3006 product manual

ABB G391 Series quick start guide

ABB

ABB G391 Series quick start guide

SCHUNK NSE mini 90 Assembly and operating manual

SCHUNK

SCHUNK NSE mini 90 Assembly and operating manual

Balluff BNI IOL-104-011-K006 user guide

Balluff

Balluff BNI IOL-104-011-K006 user guide

hager tehalit.FWK Plus Mounting instructions

hager

hager tehalit.FWK Plus Mounting instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.