MA grandMA3 Installation guide

Die in diesem Booklet enthaltenen Angaben waren zum Zeitpunkt der Drucklegung korrekt.Durch die fortlaufenden Bemühungen unseres Unternehmens, unsere Produkte
ständig zu optimieren, kann es vorkommen, dass Angaben überholt sind, wenn Sie dieses Booklet lesen.
Vervielfältigung oder Veröffentlichung dieses Booklets, auch teilweise,sind in jeglicher Form nur mit schriftlicher Genehmigung durch MA Lighting Technology GmbH erlaubt.
Änderungen sind ohne vorherige Ankündigungen möglich.
Wie übernehmen keine Haftung bei Fehlern oder Ungenauigkeiten in diesem Booklet.
The information contained in this booklet were correct at time of printing. By continuing our company’s efforts to optimize our products,it may happen that information is
outdated, at the time you read this booklet.
Without having any written permission from MA Lighting Technology GmbH it is not allowed to copy,reproduce or publish any part of this booklet, neither in printed form nor
by photos or electronic media.
All technical specifications are subject to change without notification.
We do not assume liability for any incorrect information in this booklet.
Art.Nr. 1385M00000
english | deutsch
QUICK MANUAL
MA Lighting International GmbH
An der Talle 24 – 28
33102 Paderborn · Germany
Phone: +49 52 51 68 88 65 10
www.malighting.com
© MA Lighting International
2019_v04
grandMA3
DIN-Rail
Quick-Manual-gMA3-Umschlag-27112019.indd 13-15Quick-Manual-gMA3-Umschlag-27112019.indd 13-15 27.11.19 17:1127.11.19 17:11

1
The grandMA3 xPort Nodes DIN-Rail control all kinds of lighting genres such as conventional, moving lights, LEDs, video, and media via
DMX signal or within a network environment.
All grandMA3 components, despite different hardware solutions, use the same software.
All components are fully integrable into the network environment.
Use all grandMA3 components and accessories within closed rooms and in the permissible environmental conditions only. Installation
and connection of the devices are explicitly to be carried out by trained personnel in compliance with all safety regulations.
4
Intended Use
Intended Use
Safety
Support
Transport
Limitations
Installation
Quick Start
Maintenance
Disposal
Technical Data
Declaration of Conformity
English

1
Symbols and Warning Labels
Warning:
Only trained personnel is allowed to install, power up, and operate the xPort Node DIN-Rail.
Follow your country's safety and accident prevention regulations.
Warning – Danger area
Caution– Risk of electric shock
Risk of Electric Shock
The device is to be serviced by qualified personnel only as live parts may be exposed when opening and/or removing coverings.
Touching live parts may cause electric shock.
5
Safety
Intended Use
Safety
Support
Transport
Limitations
Installation
Quick Start
Maintenance
Disposal
Technical Data
Declaration of Conformity
English

1
Dispose of as hazardous waste. Follow the applicable regulations.
For more information see Disposal.
Declaration of conformity
For more information see Conformity.
Warning:
The rail of the device has to be grounded.
Ensure that all cables are sufficiently dimensioned and fused.
Read all the instructions in this Quick Manual thoroughly, especially the General Safety Instructions further down and Limitations.
Follow the instructions and keep this Quick Manual for future use.
6
Intended Use
Safety
Support
Transport
Limitations
Installation
Quick Start
Maintenance
Disposal
Technical Data
Declaration of Conformity
English

1
Follow all cautions and warnings stated in this Quick Manual and indicated on the device.
Important:
All repair and service work has to be exclusively performed by qualified in-house service technicians. Send the device to
the factory for inspection.
This device is state-of-the-art technology;
However, residual risks cannot be ruled out;
To avoid risks, follow the safety instructions;
This device is intended for professional use only and is not suitable for residential use;
Only use this device as a fixed installation in switchboards or other closed installation cabinets.
MA Lighting Technology GmbH does not bear the damage which may occur due to inobservance of the safety instructions.
Warning:
Changes or modifications to these devices not expressly approved by the party responsible for the compliance could void
the user's authority to operate them.
7
Intended Use
Safety
Support
Transport
Limitations
Installation
Quick Start
Maintenance
Disposal
Technical Data
Declaration of Conformity
English

1
Note:
These devices have been tested and found to comply with the limits of a Class A digital device, pursuant to Part 15 of the
FCC Rules and the CE Standards. These limits are designed to provide reasonable protection against possible
interference when the devices are operated in a commercial environment. These generate, use, and can radiate radio
frequency energy and, if not installed and used in accordance with this Quick Manual, may possibly cause interference to
radio communications.
Operation of these devices in a residential area is likely to cause interference in which case the user will be required to
correct the interference at their own expense.
Avoid Risks Caused by Electric Current
A defective device or a defective power cable can cause severe or fatal injury due to electrical shock.
Follow the safety instructions to avoid the risks caused by electric current.
Before installing the device turn off the input voltage and safeguard it against unintentional power-up;
Make sure that the device is defeatable via a preliminary fuse;
To avoid contact with live parts, conceal the terminal area;
Do not use a defective power cable;
Do not open screwed down covers from the housing;
Use the device only if it is in a technically impeccable condition;
Do not repair the device on your own;
Do not reverse engineer the device, and make any changes to its components, and accessories;
Do not expose the device to rain or moisture;
Do not submerge the device in water.
General Safety Instructions
8
Intended Use
Safety
Support
Transport
Limitations
Installation
Quick Start
Maintenance
Disposal
Technical Data
Declaration of Conformity
English

1
General Safety Instructions
To avoid injury or damage to the device:
Do not put your hands inside the device during operation;
Device and power cable must be kept away from children under the age of 8;
Children are not allowed to play with the device;
Disconnect the power supply from electric voltage during thunderstorms;
Disconnect the power supply from electric voltage if it is unattended for a longer period of time;
Disconnect the power supply before cleaning the device;
Do not use any liquid or spray cleaner. Use a dry cloth only;
Do not use the device in the vicinity of water;
Do not expose it to a humid environment;
Do not pour any liquids over the device.
Do not block or cover any ventilation holes in the housing. These are essential for the airflow within the device and protect the
device from overheating;
Do not insert any objects into the ventilation holes of the device as these could get in contact with live parts or could cause short
circuits, fire and/or an electric shock;
Do not place any objects on the power cable. Protect it from being walked on or pinched, particularly at the connector and where
the cables exit the device;
When using an extension cable, make sure the rated output of all devices connected in series does not exceed the maximum rated
output of the extension cable;
Do not support yourself on the device;
Do not place any heavy objects on top of the device;
Do not use excessive force on keys, buttons, switch, connector, or rotary knob;
If the power cable or the main power plug is defective, let a qualified technician replace it immediately;
Place the device on stable surfaces only. If it is placed on unstable surfaces, it may fall and break;
Only use power cables which are safety-marked;
Do not use any high-power walkie-talkies or cell phones near the device;
The device is only be used with safety outlets.
9
Intended Use
Safety
Support
Transport
Limitations
Installation
Quick Start
Maintenance
Disposal
Technical Data
Declaration of Conformity
English

1
As with all industrially manufactured goods, the use of substances that induce an allergic reaction such as aluminum cannot be
generally excluded. If you develop an allergic reaction (such as a skin rash, frequent sneezing, red eyes or respiratory difficulties),
consult a physician immediately to determine the cause.
If one of the following conditions occurs, disconnect the main power plug and call your local distributor or the technical support!
Power cable or main power plug is damaged or worn;
Ingress of liquids;
The device was exposed to rain or high ambient humidity;
The device does not function properly, even if you followed all the instructions of this Quick Manual. Only operate the controls as
stated in the Quick Manual. Incorrect control settings may damage the device;
The device fell damaging the housing.
10
Intended Use
Safety
Support
Transport
Limitations
Installation
Quick Start
Maintenance
Disposal
Technical Data
Declaration of Conformity
English

1
MA Lighting and its extensive distributor network offer an unparalleled technical support. Call on our expertise for help with any
problem, no matter if it is about operation, software features, software installations or trouble shooting.
Online Manuals
All MA product related manuals are available as online versions. Just select your MA product and click on the according link. All further
documents can be found in our download area. Go to www.malighting.com.
Video Tutorials
Get tips and tricks from our MA experts on your MA product.
MA offers a whole range of videos on how to use your MA product in the best possible way. Just select your series and click on the
links to watch the videos on our YouTube channel. Go to www.malighting.com.
Community
Share your knowledge and get help from other MA users.
A community can be stronger and better than the individual. Be part of the MA community! Go to www.malighting.com.
Local Support
If you have a question regarding your MA Lighting product, please first of all contact your local MA product specialists.
Central Support
11
Support
Intended Use
Safety
Support
Transport
Limitations
Installation
Quick Start
Maintenance
Disposal
Technical Data
Declaration of Conformity
English

1
Central Support
If you are in need of further assistance or manufacturer support, please fill out an email request on www.malighting.com in Training
and Support. Your request will automatically be sent to support@malighting.com (in English or German). This email service is
monitored during MA Lighting's regular business hours in Germany from 8.30 am until 5 pm, Monday through Friday.
Emergency Hotline
In any case of a show critical emergency please contact the MA Lighting support hotline.
Phone +49 5251 68 88 65 99
Please note that this 24/7 hotline is strictly for emergency cases only.
12
Intended Use
Safety
Support
Transport
Limitations
Installation
Quick Start
Maintenance
Disposal
Technical Data
Declaration of Conformity
English

1
The grandMA3 xPort Node DIN-Rails must be protected from environmental factors such as physical shocks and vibration during
transportation;
Remove all cables before transport;
The user is responsible for securely fastening the products for transport and for following the manufacturer´s safety instructions
when transporting the device;
Noncompliance of the safety instructions can result in personal injury or material damage;
Do not place the grandMA3 xPort Node DIN-Rails on unstable surfaces;
Do not place any objects on top of the grandMA3 xPort Node DIN-Rails.
Warning:
Pay attention to temperature and humidity during transport. For more information see Limitations.
After the transport check the device.
If the device or its display is damaged (dented, bent or broken), do not connect the grandMA3 xPort Node DIN-Rail to
power!
13
Transport
Intended Use
Safety
Support
Transport
Limitations
Installation
Quick Start
Maintenance
Disposal
Technical Data
Declaration of Conformity
English

1
Temperature
Operation:
-10 °C up to +50 °C / 14 °F up to 122 °F
Caution:
Higher temperatures can stress the cooling system of the device and destroy hardware components.
Storage / Transport:
-10 °C up to +50 °C / 14 °F up to 122 °F
Humidity
Operation:
20 % up to 90 % relative humidity (no condensation)
Storage / Transport:
10 % up to 90 % relative humidity (no condensation)
14
Limitations
Intended Use
Safety
Support
Transport
Limitations
Installation
Quick Start
Maintenance
Disposal
Technical Data
Declaration of Conformity
English

1
Environment
Follow all safety instructions;
Only use the device within its operating limits;
Only use the device indoors;
Air must be free of dust and any hazardous or explosive substances;
Avoid jolting;
This device is not protected against splash water. Do not use it near water;
Do not use the device in rain or moisture;
Do not place the device where it can come in contact with corrosive gases or saline air as this can cause maloperation.
15
Intended Use
Safety
Support
Transport
Limitations
Installation
Quick Start
Maintenance
Disposal
Technical Data
Declaration of Conformity
English

1
Hint:
Install the grandMA3 xPort Node DIN-Rail on the rail following DIN EN 60715.
Important:
Install the grandMA3 xPort Node DIN-Rail horizontally so that the input terminal is located at the bottom and the DMX
terminal on top.
Warning:
In order for the device to dissipate heat, comply with a minimum distance of 30 mm (approx. 2 inches) above and beneath
the grandMA3 xPort Node DIN-Rail.
16
Installation
Intended Use
Safety
Support
Transport
Limitations
Installation
Quick Start
Maintenance
Disposal
Technical Data
Declaration of Conformity
English

1
Power
Connector MC 1.5/ 3-ST1-5.08
Rigid cables 0.75 mm² - 1.5 mm² (18-16 AWG)
Flexible cables 0.75 mm² - 1.5 mm² (18-16 AWG)
Wire end sleeves are permitted.
Wire stripping length 7 mm
Tightening torque 0.22 Nm - 0.25 Nm
DMX
Connector FK-MC 0.5/ 3-ST-2.5
Rigid cables 0.14 mm² - 0.5 mm² (26-20 AWG)
Flexible cables 0.14 mm² - 0.5 mm² (26-20 AWG)
Wire end sleeves are permitted.
Wire stripping length 8 mm
21
Intended Use
Safety
Support
Transport
Limitations
Installation
Quick Start
Maintenance
Disposal
Technical Data
Declaration of Conformity
English
Other manuals for grandMA3
16
Table of contents
Other MA Music Mixer manuals