Product Information Card
TCTemp2000
Product Quick Reference Card
TCTemp2000
Thermocouple Temperature Recorder with LCD Display
Part Number TCTemp2000
Temperature Sensor Semiconductor
Temperature Range -20 to +60°C
Temperature Resolution 0.1°C
Remote Channel Temperature Sensor
Range, Resolution & Accuracy *See Table for Details
Cold Jct. Compensation Automatic
Memory 131,071/channel
Sample Rate 2 second up to 24 hours
Channels 1 Internal & 1 Remote
Required Interface Package IFC110 or IFC200
Baud Rate 115,200
Typical Battery Life 1 year with display off, 30 days with
continuous LCD and no backlight
Operating Environment -20 to +60°C 0 to 95%RH
Material Black Anodized Aluminum
Dimensions 4.8” x 3.3” x 1.25” (122mm x 84mm x 32mm)
Approval CE
Specifications subject to change.
See MadgeTech’s terms and conditions at www.madgetech.com
Device Maintenance
Battery Replacement
Materials:
3/32” HEX Driver (Allen Key)
Replacement Battery (U9VL-J)
- Remove the cover from the device by unscrewing the four
screws.
- Remove the battery from its compartment and unsnap it
from the connector.
- Snap the new battery into the terminals and verify it is secure.
- Replace the cover taking care not to pinch the wires. Screw
the enclosure back together securely.
Note: Be sure not to over tighten the screws or strip the threads.
Battery Warning
WARNING: FIRE, EXPLOSION, AND SEVERE BURN HAZARD. DO NOT
SHORT CIRCUIT, CHARGE, FORCE OVER DISCHARGE, DISASSEMBLE,
CRUSH, PENETRATE OR INCINERATE. BATTERY MAY LEAK OR
EXPLODE IF HEATED ABOVE 60°C (140°F).
Recalibration
The TCTemp2000 standard calibration is one point at 25°C for the
internal channel and 0mV for the thermocouple channel.
Pricing:
Recalibration traceable to NIST $60.00
Recalibration $40.00
Additional:
As Found Data $15.00
Additional Points $15.00 per point
Channel (1st) $30.00 at 25°C
$45.00 at custom point
Additional Channels $3.00 at 25°C
$4.50 at custom point
To send the devices back, visit www.madgetech.com, select Services
then RMA Process.
* Remote Channel Range, Resolution & Accuracy
Thermocouple Range (°C) Resolution Accuracy
J -210 to +760 0.1°C +0.5°C
K -260 to +1370 0.1°C +0.5°C
T -260 to +400 0.1°C +0.5°C
E -260 to +980 0.1°C +0.5°C
R -50 to +1760 0.5°C +2.0°C
S -50 to +1760 0.5°C +2.0°C
B +60 to +1820 0.5°C +2.0°C
N -260 to +1300 0.1°C +0.5°C
TCTemp2000 Product Quick Reference Card
Wiring the Data Logger
Wiring Diagrams
The diagrams below show how to connect the thermocouple.
Warning: Note the polarity instructions. Do not attach wires to
the wrong terminals.
Product Notes
Backlight
The backlight uses a significant amount of battery life. Refer to
the manual to configure the auto shut-off when not in use.
Thermocouples and the Software
To change the thermocouple type in the MadgeTech software:
- Select Thermocouple Type from the Device Menu.
- Click on the Change button in the Thermocouple Type window.
- Select the correct thermocouple type from the drop down list.
- Click on the Save button to store the thermocouple type in
the device.
- Click OK.
Installation Guide
Installing the Interface cable
- IFC200, IFC202 or IFC300
Refer to the “Quick Start Guide” included in the package.
- IFC110, IFC102 or IFC103
Plug the serial cable into the port and verify it is secure.
- USB-1 or USB-101
Install the USB drivers from the CD provided in the kit, than
plug the USB cable into the computer and the serial cable into
the serial port.
Installing the software
Insert the Software CD in the CD-ROM Drive. If the autorun
does not appear, locate the drive on the computer and double
click on Autorun.exe. Follow the instructions provided in the
Wizard.
Connecting the data logger
- Once the software is installed and running, plug the interface
cable into the data logger.
- Click the Communication Menu, then Auto Configure Port.
- After a moment, a box similar to the following will appear;
- Click OK. The Device Status box will appear. Click OK.
- At this point, communications have been configured for your
logger. These settings can be found under the Communication
Menu.
Note: For additional installation instructions refer to your “Data
Logger & Software Operating Manual”.
Device Operation
Starting the data logger
- Click Device Menu then Start Device.
- Choose the desired start
method.
- Choose the desired stop
method.
- Choose the start parameters
by selecting a Reading Rate
suitable for the application.
- Enter in any other desired
parameters and click Start.
- A box will appear stating
the data logger has been
started. Click OK.
- Disconnect the data logger from the interface cable and
place it in the environment to measure.
Note: The device will stop recording data when the end of
memory is reached or the device is stopped. At this point the
device cannot be restarted until it has been re-armed by the
computer.
Downloading data from a data logger
- Connect the data logger to the interface cable.
- Click the Device Menu then Read Device Data. This will
offload all recorded data onto the PC.
Technical Support
Visit www.madgetech.com, or call (603) 456-2011.
Technical support is also available by e-mailing
[email protected]
Additional product information is available by e-mailing
[email protected].
+ Input
- Input
Connector for interface cable

Other manuals for TCTemp2000

1

Other MadgeTech Voice Recorder manuals

MadgeTech RTDTemp2000 Reference guide

MadgeTech

MadgeTech RTDTemp2000 Reference guide

MadgeTech RFRHTemp101A User manual

MadgeTech

MadgeTech RFRHTemp101A User manual

MadgeTech QuadTemp Reference guide

MadgeTech

MadgeTech QuadTemp Reference guide

MadgeTech TransiTempII-RH User manual

MadgeTech

MadgeTech TransiTempII-RH User manual

Popular Voice Recorder manuals by other brands

Fostex MR-8HD/CD manual

Fostex

Fostex MR-8HD/CD manual

Samsung Voice Yepp VY-H200S user guide

Samsung

Samsung Voice Yepp VY-H200S user guide

Philips VoiceTracer DVT4010 user manual

Philips

Philips VoiceTracer DVT4010 user manual

Olympus dm-770 user manual

Olympus

Olympus dm-770 user manual

LogTag Recorders USRIC-4 Product user guide

LogTag Recorders

LogTag Recorders USRIC-4 Product user guide

Adaptivation Randomizer Gamer instruction manual

Adaptivation

Adaptivation Randomizer Gamer instruction manual

Sony ICD-TX50 quick start guide

Sony

Sony ICD-TX50 quick start guide

Olympus VN-801PC instructions

Olympus

Olympus VN-801PC instructions

Sony ICD-BP operating instructions

Sony

Sony ICD-BP operating instructions

Sony TCM-323 - Micro Portable Recorder operating instructions

Sony

Sony TCM-323 - Micro Portable Recorder operating instructions

Yellowtec iXm Briefing Book

Yellowtec

Yellowtec iXm Briefing Book

Superior KW 87 MP3 user manual

Superior

Superior KW 87 MP3 user manual

Telectro 333 manual

Telectro

Telectro 333 manual

ARTECH AK Series user manual

ARTECH

ARTECH AK Series user manual

Shining Technology CitiDISK DV FW1256B Quick usage guide

Shining Technology

Shining Technology CitiDISK DV FW1256B Quick usage guide

RCA VR4210GB Manual de usuario

RCA

RCA VR4210GB Manual de usuario

Olympus VN-7600PC instructions

Olympus

Olympus VN-7600PC instructions

Samsung yePP VY-S100 user guide

Samsung

Samsung yePP VY-S100 user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.