05 Oct 2021, V2
BRD02 Traffic Detector
Installation and Wiring
Menu selection
Setting instruction:
1. Press and hold the button for 3 seconds.
2. Wait till all 3 LED light starts to blink.
3. The red light will be blinking from left to right.
4. Let go the button when the blinking LED is the menu you
want. (Look at Table 1)
5. The LED will turn green once in the setting.
6. Adjust setting by using the button.
7. After done, press and hold the button until all red LED
flash then let go the button, it will automatically save and
exits the menu.
*(Note: After setting, it must be saved; otherwise the setting
will not change and the detector will automatically exit the
menu setting after 10 seconds)
©2021 QG V2 BRD02
2
Default distance is 2.5 meter.
When detection distance is 1 meter,
Green light LED 1 is Hold.
When detection distance is 1.5 meter,
Green light LED 1 is blinking
The longer the detection distance, the
more LED will turn on.
Setting instruction:
1. Press and hold the button to enter Menu 1.(Look at table 1)
2. When the LED 1 red light is on. Let go the button.
3. Press the button to set the distance.(Look at Table 2)
4. After select distance. Press and hold the button, all 3 LED
red light start blinking.
5. After setting is done only LED 2 red light will on.
*(Note: Make sure detection range is 0.5 meter less then the
actual arm length)
Function Parameter Setting and Description
Traffic Detector Parameter Setting
Default sensitivity is medium.
When sensitivity is medium, LED
2 green light is Hold.
Higher sensitivity, different LED
will turn on from LED 1 to 3.
Setting instruction:
1. Press and hold the button to enter Menu
2. (Look at table 1)
2. When the LED 2 red light is on. Let go
the button.
3. Press the button to adjust the sensitivity.
(Look at table 3)
4. After selecting sensitivity, press and
hold the button until all 3 LED red light
start blinking.
5. After setting is done only LED 2 red light
will on.
1) Detection distance
It is compulsory to perform background calibration for radar to
learn the new ambient environment to ensure accurate detection.
Setting instruction:
1. Before start update background make sure there is nothing in
front of the radar detector distance.(Default distance 2.5
meters)
2. Turn off the power supply.
3. Press and hold the button.
4. Turn on the power supply.
5. Quickly let go the button when the three green LED light turn
ON.
6. Press the button 5 times. You will see green light on LED 1 &
LED 3 start blinking.
7. After update is completed only red LED 2 light will remain ON.
SPECIAL NOTE
* Make sure to use low noise power supply.
*Only install the BRD02 on flat surface and do not
install it in front uneven road surface.
SCAN HERE:
© COPYRIGHT 2021.This documentation served as a reference only. It is subject to change without further notice.
All the diagrams and information in this documentation may not be duplicated or modified in any form without the
written approval from the management.
3) Compulsory background calibration
2) Detection sensitivity
*For fence arm barrier setting,
please refer to full installation
manual.
*For full installation manual
and setting, please scan the
QR Code beside.
*(Note: For Trucks or High Base Vehicle Please set sensitivity to
High and refer to the installation manual for more information.)

Other MAG Security Sensor manuals

MAG BRD02 User manual

MAG

MAG BRD02 User manual

MAG BRD02 User manual

MAG

MAG BRD02 User manual

MAG BRD03 User manual

MAG

MAG BRD03 User manual

Popular Security Sensor manuals by other brands

3M DBI SALA 2108406 User instruction manual

3M

3M DBI SALA 2108406 User instruction manual

Diablo DSP-22-1 user manual

Diablo

Diablo DSP-22-1 user manual

Forney IDD-II manual

Forney

Forney IDD-II manual

Aqara TH-S02D user manual

Aqara

Aqara TH-S02D user manual

Weco CDZ Series user manual

Weco

Weco CDZ Series user manual

Keysight 8478B Operating and service manual

Keysight

Keysight 8478B Operating and service manual

STEINEL IS 3180 installation instructions

STEINEL

STEINEL IS 3180 installation instructions

Emerson Rosemount 975 Series Reference manual

Emerson

Emerson Rosemount 975 Series Reference manual

BEROTEC CUMPAN FANTIC Caballero 500 user guide

BEROTEC

BEROTEC CUMPAN FANTIC Caballero 500 user guide

HELVAR 314 Tilting installation guide

HELVAR

HELVAR 314 Tilting installation guide

EMX Industries ULT-V2 instruction manual

EMX Industries

EMX Industries ULT-V2 instruction manual

Bircher Reglomat PrimeTec B Original instructions

Bircher Reglomat

Bircher Reglomat PrimeTec B Original instructions

Werner 79208 User instructions

Werner

Werner 79208 User instructions

Pentatech CO30 Operating instructions and safety instructions

Pentatech

Pentatech CO30 Operating instructions and safety instructions

Varex Imaging 4343W manual

Varex Imaging

Varex Imaging 4343W manual

Cerberus ILP-2 Installation/Wiring Instructions

Cerberus

Cerberus ILP-2 Installation/Wiring Instructions

Greenlee GT-16 instruction manual

Greenlee

Greenlee GT-16 instruction manual

Hokuyo UGM-50LXP manual

Hokuyo

Hokuyo UGM-50LXP manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.